Lung sounds acquired by stethoscopes are extensively used in diagnosing and differentiating respiratory diseases. Although an extensive know-how has been built to interpret these sounds and identify diseases associated with certain patterns, its effective use is limited to individual experience of practitioners. This user-dependency manifests itself as a factor impeding the digital transformation of this valuable diagnostic tool, which can improve patient outcomes by continuous long-term respiratory monitoring under real-life conditions. Particularly patients suffering from respiratory diseases with progressive nature, such as chronic obstructive pulmonary diseases, are expected to benefit from long-term monitoring. Recently, the COVID-19 pandemic has also shown the lack of respiratory monitoring systems which are ready to deploy in operational conditions while requiring minimal patient education. To address particularly the latter subject, in this article, we present a sound acquisition module which can be integrated into a dedicated garment; thus, minimizing the role of the patient for positioning the stethoscope and applying the appropriate pressure. We have implemented a diaphragm-less acousto-electric transducer by stacking a silicone rubber and a piezoelectric film to capture thoracic sounds with minimum attenuation. Furthermore, we benchmarked our device with an electronic stethoscope widely used in clinical practice to quantify its performance.
Epilepsy is characterized by the occurrence of epileptic events, ranging from brief bursts of interictal epileptiform brain activity to their most dramatic manifestation as clinically overt bilateral tonic–clonic seizures. Epileptic events are often modulated in a patient-specific way, for example by sleep. But they also reveal temporal patterns not only on ultra- and circadian, but also on multidien scales. Thus, to accurately track the dynamics of epilepsy and to thereby enable and improve personalized diagnostics and therapies, user-friendly systems for long-term out-of-hospital recordings of electrical brain signals are needed. Here, we present two wearable devices, namely ULTEEM and ULTEEMNite, to address this unmet need. We demonstrate how the usability concerns of the patients and the signal quality requirements of the clinicians have been incorporated in the design. Upon testbench verification of the devices, ULTEEM was successfully benchmarked against a reference EEG device in a pilot clinical study. ULTEEMNite was shown to record typical macro- and micro-sleep EEG characteristics in a proof-of-concept study. We conclude by discussing how these devices can be further improved and become particularly useful for a better understanding of the relationships between sleep, epilepsy, and neurodegeneration.
Biopotential imaging (e.g., ECGi, EEGi, EMGi) processes multiple potential signals, each requiring an electrode applied to the body’s skin. Conventional approaches based on individual wiring of each electrode are not suitable for wearable systems. Cooperative sensors solve the wiring problem since they consist of active (dry) electrodes connected by a two-wire parallel bus that can be implemented, for example, as a textile spacer with both sides made conductive. As a result, the cumbersome wiring of the classical star arrangement is replaced by a seamless solution. Previous work has shown that potential reference, current return, synchronization, and data transfer functions can all be implemented on a two-wire parallel bus while keeping the noise of the measured biopotentials within the limits specified by medical standards. We present the addition of the power supply function to the two-wire bus. Two approaches are discussed. One of them has been implemented with commercially available components and the other with an ASIC. Initial experimental results show that both approaches are feasible, but the ASIC approach better addresses medical safety concerns and offers other advantages, such as lower power consumption, more sensors on the two-wire bus, and smaller size.
Classical approaches for measuring high-quality ECG require the use of gel electrodes and individually shielded cables, which limit patient comfort, especially in long-term use. We recently introduced a novel sensing architecture-so-called cooperative sensors-that allow the use of active dry electrodes connected by two unshielded wires. The aim of this work is to qualitatively evaluate an ECG recorded with a dry-electrode cooperative-sensor system. To that end, preliminary observations were made on three healthy subjects. The ECGs were concurrently recorded with cooperative sensors and a gold-standard 12-lead ECG device during a stress test on a stationary bicycle. First experimental measurements demonstrated the reliability of the approach for a wearable 12-lead ECG monitoring system tested in real settings.
Bioimpedance imaging aims to generate a 3D map of the resistivity and permittivity of biologi-cal tissue from multiple impedance channels measured with electrodes applied to the skin. When the electrodes are distributed around the body (for example, by delineating a cross-section of the chest or a limb), bioimpedance imaging is called electrical impedance tomography (EIT) and results in 2D functional images. Conventional EIT systems rely on individually cabling each electrode to master electronics in a star configuration. This approach works well for rack-mounted equipment; however, the bulkiness of the cabling is unsuitable for a wearable system. Previously presented cooperative sensors solve this cabling problem using active (dry) elec-trodes connected via a two-wire parallel bus. The bus can be implemented with two unshielded wires or even two conductive textile layers, thus replacing the cumbersome wiring of the con-ventional star arrangement. Prior research demonstrated cooperative sensors for measuring bi-oimpedances, successfully realizing a measurement reference signal, sensor synchronization, and data transfer though still relying on individual batteries to power the sensors. Subsequent research using cooperative sensors for biopotential measurements proposed a method to re-move batteries from the sensors and have the central unit supply power over the two-wire bus. Building off our previous research, this paper presents this method applied to the measurements of bioimpedances. Two different approaches are discussed, one using discrete, commercially available components, and the other with an application specific integrated circuit (ASIC). Initial experimental results reveal that both approaches are feasible, but the ASIC approach offers ad-vantages for medical safety, as well as lower power consumption and smaller size.
While most heart arrhythmias are not immediately harmful, they can lead to severe complications. In particular, atrial fibrillation, the most common arrhythmia, is characterized by fast and irregular heart beats and increases the risk of suffering a stroke. To detect such abnormal heart conditions, we propose a system composed of two main parts: a smart vest with two cooperative sensors to collect ECG data and a neural network architecture to classify heart rhythms. The smart vest uses two dry bi-electrodes to record a single lead ECG signal. The biopotential signal is then streamed via a gateway to the cloud where a neural network detects and classifies the heart arrhythmias. We selected an architecture that combines convolutional and recurrent layers. The convolutional layers extract relevant features from sliding windows of ECG and the recurrent layer aggregates them for a final softmax layer that performs the classification. Our neural network achieves an accuracy of 87.50% on the dataset of the challenge of Computing in Cardiology 2017.