Thitirat Mantim

Dr. Thitirat Mantim

Department of Chemistry, Faculty of Science, Srinakharinwirot University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2020 in Molecules
Verified
Journal Article
Open access
PDF file
TMThitirat Mantim
Thitirat Mantim
KCKorbua Chaisiwamongkhol
Korbua Chaisiwamongkhol
KUKanchana Uraisin
Kanchana Uraisin
Peter HauserPeter Hauser
Peter Hauser
PWPrapin Wilairat
Prapin Wilairat
DNDuangjai Nacapricha
Duangjai Nacapricha
This work presents a new dual-purpose detector for photometric and conductivity measurements in flow-based analysis. The photometric detector is a paired emitter–detector diode (PEDD) device, whilst the conductivity detection employs a capacitively coupled contactless conductivity detector (C4D). The flow-through detection cell is a rectangular acrylic block (ca. 2 × 2 × 1.5 cm) with cylindrical channels in Z-configuration. For the PEDD detector, the LED light source and detector are installed inside the acrylic block. The two electrodes of the C4D are silver conducting ink painted on the PEEK inlet and outlet tubing of the Z-flow cell. The dual-purpose detector is coupled with a sequential injection analysis (SIA) system for simultaneous detection of the absorbance of the orange dye and conductivity of the dissolved oral rehydration salt powder. The detector was also used for sequential measurements of creatinine and the conductivity of human urine samples. The creatinine analysis is based on colorimetric detection of the Jaffé reaction using the PEDD detector, and the conductivity of the urine, as measured by the C4D detector, is expressed in millisiemens (mS cm−1).

30 January 2023 in Molecules
Verified
Journal Article
Open access
PDF file
TSThachkorn Somboonsuk
Thachkorn Somboonsuk
PSPhoonthawee Saetear
Phoonthawee Saetear
TMThitirat Mantim
Thitirat Mantim
NRNuanlaor Ratanawimarnwong
Nuanlaor Ratanawimarnwong
PWPrapin Wilairat
Prapin Wilairat
NCNathawut Choengchan
Nathawut Choengchan
This work presents the use of a transparent ‘Cross Injection Analysis’ (CIA) platform as a flow system for chemiluminescence (CL) measurements. The CL-CIA flow device incorporates introduction channels for samples and reagents, and the reaction and detection channels are in one acrylic unit. A photomultiplier tube placed above the reaction channel detects the emitted luminescence. The system was applied to the analysis of (i) Co(II) via the Co(II)-catalyzed H2O2-luminol reaction and (ii) paracetamol via its inhibitory effect on the catalytic activity of Fe(CN)63− on the H2O2-luminol reaction. A linear calibration was obtained for Co(II) in the range of 0.002 to 0.025 mg L−1 Co(II) (r2 = 0.9977) for the determination of Co(II) in water samples. The linear calibration obtained for the paracetamol was 10 to 200 mg L−1 (r2 = 0.9906) for the determination of pharmaceutical products. The sample throughput was 60 samples h−1. The precision was ≤4.2% RSD. The consumption of the samples and reagents was ca. 170 µL per analysis cycle.