This work presents a simple and innovative protocol employing a microfluidic paper-based analytical device (µPAD) for equipment-free determination of mercury. In this method, mercury (II) forms an ionic-association complex of tetraiodomercurate (II) ion (HgI42−(aq)) using a known excess amount of iodide. The residual iodide flows by capillary action into a second region of the paper where it is converted to iodine by pre-deposited iodate to liberate I2(g) under acidic condition. Iodine vapor diffuses across the spacer region of the µPAD to form a purple colored of tri-iodide starch complex in a detection zone located in a separate layer of the µPAD. The digital image of the complex is analyzed using ImageJ software. The method has a linear calibration range of 50–350 mg L−1 Hg with the detection limit of 20 mg L−1. The method was successfully applied to the determination of mercury in contaminated soil and water samples which the results agreed well with the ICP-MS method. Three soil samples were highly contaminated with mercury above the acceptable WHO limits (0.05 mg kg−1). To the best of our knowledge, this is the first colorimetric µPAD method that is applicable for soil samples including mercury contaminated soils from gold mining areas.
This work reports the preparation and utility of cysteine-functionalized carbon-coated Fe3O4 materials (Cys-C@Fe3O4) as efficient sorbents for remediation of Hg(II)-contaminated water. Efficient removal (90%) of Hg(II) from 1000 ppb aqueous solutions is possible, at very low Cys-C@Fe3O4 sorbent loadings (0.01 g sorbent per liter of Hg(II) solution). At low metal concentrations (5–100 ppb Hg(II)), where adsorption is typically slow, Hg(II) removal efficiencies of 94–99.4% were achievable, resulting in final Hg(II) levels of <1.0 ppb. From adsorption isotherms, the Hg(II) adsorption capacity for Cys-C@Fe3O4 is 94.33 mg g−1, around three times that of carbon-coated Fe3O4 material. The highest partition coefficient (PC) of 2312.5 mgg−1µM−1 was achieved at the initial Hg (II) concentration of 100 ppb, while significantly high PC values of 300 mgg−1µM−1 and above were also obtained in the ultralow concentration range (≤20 ppb). Cys-C@Fe3O4 exhibits excellent selectivity for Hg(II) when tested in the presence of Pb(II), Ni(II), and Cu(II) ions, is easily separable from aqueous media by application of an external magnet, and can be regenerated for three subsequent uses without compromising Hg(II) uptake. Derived from commercially available raw materials, it is highly possible to achieve large-scale production of the functional sorbent for practical applications.
This work presents a new dual-purpose detector for photometric and conductivity measurements in flow-based analysis. The photometric detector is a paired emitter–detector diode (PEDD) device, whilst the conductivity detection employs a capacitively coupled contactless conductivity detector (C4D). The flow-through detection cell is a rectangular acrylic block (ca. 2 × 2 × 1.5 cm) with cylindrical channels in Z-configuration. For the PEDD detector, the LED light source and detector are installed inside the acrylic block. The two electrodes of the C4D are silver conducting ink painted on the PEEK inlet and outlet tubing of the Z-flow cell. The dual-purpose detector is coupled with a sequential injection analysis (SIA) system for simultaneous detection of the absorbance of the orange dye and conductivity of the dissolved oral rehydration salt powder. The detector was also used for sequential measurements of creatinine and the conductivity of human urine samples. The creatinine analysis is based on colorimetric detection of the Jaffé reaction using the PEDD detector, and the conductivity of the urine, as measured by the C4D detector, is expressed in millisiemens (mS cm−1).
This work presents a novel method for simultaneous spectrophotometric determination of phosphate and silicate by using a cross injection analysis (CIA) coupled with the use of partial least squares (PLS) for data evaluation. The detection principle is based on the well-known ‘molybdenum blue’ method. The molybdate ions in the presence of stannous chloride in acidic medium give phosphomolybdenum blue and silicomolybdenum blue as products. In this work, all the liquids, including sample and reagents were simultaneously introduced into a CIA platform by using two peristaltic pumps for controlling the x-channel and y-channel flow which was automatically manipulated by using in-house control board. Crossflow provides sufficient mixing inside the platform prior detection of the absorption spectra of blue complexes in the wavelength of 400–900 nm. Since spectra of the blue colour product of phosphate and silicate are resemblant, these two analytes therefore reciprocally interfere with one another. This results in difficulty in simultaneous analysis of phosphate and silicate. In this work, PLS was utilised as assistor of CIA system for simultaneous analysis of phosphate and silicate using molybdenum blue reaction without using any modification of reagents and addition of selective masking agent. The calibration ranges are 0.1–6 mgP L−1 and 5–100 mgSi L−1 for phosphate and silicate, respectively. By using CIA coupled with PLS for data evaluation, the analysis of two analytes was achieved within 1.5 min with only single injection. The developed system was applied to natural water samples and the system was validated with the conventional methods. By statistical paired t-test, there was no evidence of significant difference at 95% confidence level (tstat = 2.28, tcritical = 2.31 and tstat = 0.62, tcritical = 2.31 for phosphate and silicate, respectively). This implied that the chemometrics-assisted CIA system was successfully developed for simultaneous spectrophotometric determination of phosphate and silicate.