Dual-energy virtual noncalcium CT images provide excellent diagnostic performance in visual and region of interest–based evaluation of bone marrow infiltration in patients with multiple myeloma. PurposeTo determine the diagnostic performance of dual-energy computed tomography (CT) for detection of bone marrow (BM) infiltration in patients with multiple myeloma by using a virtual noncalcium (VNCa) technique.Materials and MethodsIn this prospective study, 34 consecutive patients with multiple myeloma or monoclonal gammopathy of unknown significance sequentially underwent dual-energy CT and magnetic resonance (MR) imaging of the axial skeleton. Two independent readers visually evaluated standard CT and color-coded VNCa images for the presence of BM involvement. MR imaging served as the reference standard. Analysis on the basis of the region of interest (ROI) of VNCa CT numbers of infiltrated (n = 75) and normal (n = 170) BM was performed and CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values.ResultsIn the visual analysis, VNCa images had an overall sensitivity of 91.3% (21 of 23), specificity of 90.9% (10 of 11), accuracy of 91.2% (31 of 34), positive ...
Purpose: We aimed to determine the impact of fibroblast activation protein inhibitor (FAPI)–directed molecular imaging on staging and therapeutic management in patients affected with digestive system tumors when compared with guideline-compatible imaging (GCI). Patients and Methods: Thirty-two patients with tumors of the digestive system were included: colon adenocarcinoma, 2/32 (6.3%); hepatocellular carcinoma (HCC), 6/32 (18.8%); pancreatic duct adenocarcinoma (PDAC), 6/32 (18.8%), and gastroenteropancreatic neuroendocrine neoplasms, 18/32 (56.3%). All patients underwent GCI and 68Ga-FAPI-04 PET/CT within median 4 days. Staging outcomes and subsequent treatment decisions were compared between GCI and 68Ga-FAPI-04 PET/CT. Results: Compared with GCI, 68Ga-FAPI-04 PET/CT led to staging changes in 15/32 patients (46.9%). Among those, downstaging was recorded in 3/15 cases (20.0%) and upstaging in the remaining 12/15 patients (HCC, 4/12 [33.3%]; PDAC, 4/12 [33.3%]; neuroendocrine neoplasms, 3/12 [25%]; colon adenocarcinoma, 1/12 [8.3%]). Therapeutic management was impacted in 8/32 patients (25.0%), including 4 instances of major and 4 instances of minor therapeutic changes. The highest proportion of treatment modifications was observed in patients diagnosed with PDAC and HCC in 6/8 (75%). Conclusions: In patients affected with digestive system tumors, 68Ga-FAPI-04 PET/CT resulted in staging changes in more than 46% and therapeutic modifications in 25% of the cases, in particular in patients with HCC and PDAC. In clinical routine, such findings may favor a more widespread adoption of FAP-directed imaging in those tumor types.
To investigate the feasibility, diagnostic image quality and radiation dose of 3rd generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scan-protocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP). All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv. Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases.
26 April 2017 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Purpose To compare radiation dose, subjective and objective image quality of 3 rd generation dual-source CT (DSCT) and dual-energy CT (DECT) with conventional 64-slice single-source CT (SSCT) for pulmonary CTA. Materials and Methods 180 pulmonary CTA studies were performed in three patient cohorts of 60 patients each. Group 1: conventional SSCT 120 kV (ref.); group 2: single-energy DSCT 100 kV (ref.); group 3: DECT 90/Sn150 kV. CTDIvol, DLP, effective radiation dose were reported, and CT attenuation (HU) was measured on three central and peripheral levels. The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Two readers assessed subjective image quality according to a five-point scale. Results Mean CTDIvol and DLP were significantly lower in the dual-energy group compared to the SSCT group (p < 0.001 [CTDIvol]; p < 0.001 [DLP]) and the DSCT group (p = 0.003 [CTDIvol]; p = 0.003 [DLP]), respectively. The effective dose in the DECT group was 2.79 ± 0.95 mSv and significantly smaller than in the SSCT group (4.60 ± 1.68 mSv, p < 0.001) and the DSCT group (4.24 ± 2.69 mSv, p = 0.003). The SNR and CNR were significantly higher in the DSCT group (p < 0.001). Subjective image quality did not differ significantly among the three protocols and was rated good to excellent in 75 % (135/180) of cases with an inter-observer agreement of 80 %. Conclusion Dual-energy pulmonary CTA protocols of 3 rd generation dual-source scanners allow for significant reduction of radiation dose while providing excellent image quality and potential additional information by means of perfusion maps. Key Points: Citation Format
Purpose: Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B0‐field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed.Methods: The spatial B0‐field distribution in the heart was analyzed as well as temporal B0‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration‐based B0‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming.Results: The strongest B0‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B0‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents.Conclusion: Challenges in state‐of‐the‐art B0 shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.