Dual-energy virtual noncalcium CT images provide excellent diagnostic performance in visual and region of interest–based evaluation of bone marrow infiltration in patients with multiple myeloma. PurposeTo determine the diagnostic performance of dual-energy computed tomography (CT) for detection of bone marrow (BM) infiltration in patients with multiple myeloma by using a virtual noncalcium (VNCa) technique.Materials and MethodsIn this prospective study, 34 consecutive patients with multiple myeloma or monoclonal gammopathy of unknown significance sequentially underwent dual-energy CT and magnetic resonance (MR) imaging of the axial skeleton. Two independent readers visually evaluated standard CT and color-coded VNCa images for the presence of BM involvement. MR imaging served as the reference standard. Analysis on the basis of the region of interest (ROI) of VNCa CT numbers of infiltrated (n = 75) and normal (n = 170) BM was performed and CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values.ResultsIn the visual analysis, VNCa images had an overall sensitivity of 91.3% (21 of 23), specificity of 90.9% (10 of 11), accuracy of 91.2% (31 of 34), positive ...
Visual and quantitative analyses of dual-energy virtual noncalcium images had excellent diagnostic performance in the depiction of traumatic bone marrow edema in patients with vertebral compression fractures. Purpose To assess the diagnostic performance of a third-generation dual-energy computed tomographic (CT) virtual noncalcium (VNCa) technique for detection of traumatic bone marrow edema in patients with vertebral compression fractures. Materials and Methods This prospective study was approved by the institutional review board. Informed consent was obtained from all participants. Twenty-two consecutive patients with 37 morphologic vertebral fractures were studied between October 2015 and May 2016. All patients underwent dual-energy CT (90 kV and 150 kV with a tin filter) and 3-T magnetic resonance (MR) imaging. Two independent readers visually evaluated all vertebral bodies (n = 163) for the presence of abnormal bone marrow attenuation on VNCa images by using color-coded maps and performed a quantitative analysis of CT numbers on VNCa images. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values. Results In the visual ...
Colorectal cancer (CRC) is the third most common malignancy worldwide. Most patients with metastatic CRC develop liver or lung metastases, while a minority suffer from brain metastases. There is little information available regarding the presentation, treatment, and overall survival of brain metastases (BM) from CRC. This systematic review and meta-analysis includes data collected from three major databases (PubMed, Cochrane, and Embase) based on the key words “brain”, “metastas*”, “tumor”, “colorectal”, “cancer”, and “malignancy”. In total, 1318 articles were identified in the search and 86 studies matched the inclusion criteria. The incidence of BM varied between 0.1% and 11.5%. Most patients developed metastases at other sites prior to developing BM. Lung metastases and KRAS mutations were described as risk factors for additional BM. Patients with BM suffered from various symptoms, but up to 96.8% of BM patients were asymptomatic at the time of BM diagnosis. Median survival time ranged from 2 to 9.6 months, and overall survival (OS) increased up to 41.1 months in patients on a multimodal therapy regimen. Several factors including age, blood levels of carcinoembryonic antigen (CEA), multiple metastases sites, number of brain lesions, and presence of the KRAS mutation were predictors of OS. For BM diagnosis, MRI was considered to be state of the art. Treatment consisted of a combination of surgery, radiation, or systemic treatment.
Objectives: The aim of this study was to assess in-stent lumen visibility and quantitative image characteristics of different coronary stents using a novel photon-counting detector (PCD) computed tomography (CT) system in comparison to a state-of-the-art energy-integrating detector (EID) CT scanner. Materials and Methods: In this in vitro phantom study, 28 different coronary stents ranging from 2.25 to 4.5 mm lumen diameter were expanded into plastic tubes filled with contrast agent. Stent-containing plastic tubes were positioned in a custom-made emulsion-filled phantom, which was inserted into an anthropomorphic phantom simulating a medium-sized patient. Computed tomography scans were acquired parallel to the scanners’ z axis using a novel cadmium telluride–based PCD CT system (SOMATOM CountPlus; Siemens Healthcare GmbH, Forchheim Germany), operating in 2 different modes (standard-resolution mode [SR] and ultra-high-resolution [UHR] mode), and a latest generation dual-source EID CT system (SOMATOM Force; Siemens Healthcare GmbH, Forchheim). CTDIvol-matched images were reconstructed with comparable convolution kernels and using the same reconstruction parameters. In-stent lumen visibility (in %), increase in in-stent attenuation (expressed as Δ in-stent CT attenuation), and image noise (in Hounsfield unit) were manually measured. Parts of the image analysis (in-stent lumen visibility) were additionally performed in an automated way. Differences were tested using Wilcoxon signed rank test. Results: The best in-stent lumen visibility was achieved with the PCD-UHR mode and the lowest noise levels with the PCD-SR mode. The median in-stent lumen visibility was significantly higher (P < 0.001) with PCD (SR, 66.7%; interquartile range [IQR], 63.3–72.3; UHR, 68.9%; IQR, 64.4–74.4) compared with EID (65.4%; IQR, 62.2–70.4). The Δ in-stent CT attenuation was significantly lower for PCD in both SR (78 HU; IQR, 46–108; P = 0.024) and UHR (85 HU; IQR, 59–113; P = 0.006) compared with EID (108 HU; IQR, 85–126). Image noise was significantly lower (P < 0.001) for PCD-SR (21 HU; IQR, 21–21) compared with EID images (25 HU; IQR, 24–25.0). Conclusions: The PCD provides superior in-stent lumen visibility and quantitative image characteristics when compared with conventional EID.
To investigate the feasibility, diagnostic image quality and radiation dose of 3rd generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scan-protocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP). All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv. Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases.
26 April 2017 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Purpose To compare radiation dose, subjective and objective image quality of 3 rd generation dual-source CT (DSCT) and dual-energy CT (DECT) with conventional 64-slice single-source CT (SSCT) for pulmonary CTA. Materials and Methods 180 pulmonary CTA studies were performed in three patient cohorts of 60 patients each. Group 1: conventional SSCT 120 kV (ref.); group 2: single-energy DSCT 100 kV (ref.); group 3: DECT 90/Sn150 kV. CTDIvol, DLP, effective radiation dose were reported, and CT attenuation (HU) was measured on three central and peripheral levels. The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Two readers assessed subjective image quality according to a five-point scale. Results Mean CTDIvol and DLP were significantly lower in the dual-energy group compared to the SSCT group (p < 0.001 [CTDIvol]; p < 0.001 [DLP]) and the DSCT group (p = 0.003 [CTDIvol]; p = 0.003 [DLP]), respectively. The effective dose in the DECT group was 2.79 ± 0.95 mSv and significantly smaller than in the SSCT group (4.60 ± 1.68 mSv, p < 0.001) and the DSCT group (4.24 ± 2.69 mSv, p = 0.003). The SNR and CNR were significantly higher in the DSCT group (p < 0.001). Subjective image quality did not differ significantly among the three protocols and was rated good to excellent in 75 % (135/180) of cases with an inter-observer agreement of 80 %. Conclusion Dual-energy pulmonary CTA protocols of 3 rd generation dual-source scanners allow for significant reduction of radiation dose while providing excellent image quality and potential additional information by means of perfusion maps. Key Points: Citation Format