Valentina Corino

Prof. Valentina Corino

Politecnico di Milano, Milan, Italy
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2017 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
VCValentina Corino
Valentina Corino
EMEros Montin
Eros Montin
AMAntonella Messina
Antonella Messina
PCPaolo G. Casali
Paolo G. Casali
AGAlessandro Gronchi
Alessandro Gronchi
LMLuca T. Mainardi
Luca T. Mainardi

27 April 2017 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
VCValentina Corino
Valentina Corino
RLRita Laureanti
Rita Laureanti
LFLorenzo Ferranti
Lorenzo Ferranti
GSGiorgio Scarpini
Giorgio Scarpini
FLFederico Lombardi
Federico Lombardi
LMLuca T Mainardi
Luca T Mainardi
Objective: Undiagnosed atrial fibrillation (AF) patients are at high risk of cardioembolic stroke or other complications. The aim of this study was to analyze the blood volume pulse (BVP) signals obtained from a wristband device and develop an algorithm for discriminating AF from normal sinus rhythm (NSR) or from other arrhythmias (ARR). Approach: Thirty patients with AF, 9 with ARR and 31 in NSR were included in the study. The recordings were obtained at rest from Empatica E4 wristband device and lasted 10 min. The analysis, on a 2 min segment, included spectral, variability and irregularity analysis performed on the inter-diastolic interval series, and similarity analysis performed on the BVP signal. Main results and Significance: Variability parameters were the highest in AF, the lowest in NSR and intermediate for ARR, as an example pNN50 values were, respectively, 81 ± 8 , 20 ± 5 , 55 ± 27 ( p < 0.05). The similarity parameters were the highest in NSR, the lowest in AF and intermediate for ARR, as an example using a threshold for assessing similarity of π / 4 : 0.90 ± 0.09 , 0.40 ± 0.20 , 0.58 ± 0.23 , all p < 0.05. The rhythm classification was preceded by over-sampling (using synthetic minority over-sampling technique) the class of ARR, being it the smallest class. Then, the features selection was performed (using the sequential forward floating search algorithm) which identified two variability parameters (pNN70 and pNN40) as the best selection. The classification by the k-nearest neighbor classifier reached an accuracy of about 0.9 for NSR and AF, and 0.8 for ARR. Using pNN70 and pNN40, the specificity for the three rhythms was Sp nsr = 0.928, Sp af = 0.963, Sp arr = 0.768, while the sensitivity was Sp nsr = 0.773, Sp af = 0.754, Sp arr = 0.758.

28 February 2024 in Computers in Biology and Medicine
Verified
Journal Article
Open access
PMPedro A. Moreno-Sanchez
Pedro A. Moreno-Sanchez
GGGuadalupe García-Isla
Guadalupe García-Isla
VCValentina Corino
Valentina Corino
AVAntti Vehkaoja
Antti Vehkaoja
KBKirsten Brukamp
Kirsten Brukamp
LMLuca Mainardi
Luca Mainardi
Cardiovascular diseases (CVD) are a leading cause of death globally, and result in significant morbidity and reduced quality of life. The electrocardiogram (ECG) plays a crucial role in CVD diagnosis, prognosis, and prevention; however, different challenges still remain, such as an increasing unmet demand for skilled cardiologists capable of accurately interpreting ECG. This leads to higher workload and potential diagnostic inaccuracies. Data-driven approaches, such as machine learning (ML) and deep learning (DL) have emerged to improve existing computer-assisted solutions and enhance physicians' ECG interpretation of the complex mechanisms underlying CVD. However, many ML and DL models used to detect ECG-based CVD suffer from a lack of explainability, bias, as well as ethical, legal, and societal implications (ELSI). Despite the critical importance of these Trustworthy Artificial Intelligence (AI) aspects, there is a lack of comprehensive literature reviews that examine the current trends in ECG-based solutions for CVD diagnosis or prognosis that use ML and DL models and address the Trustworthy AI requirements. This review aims to bridge this knowledge gap by providing a systematic review to undertake a holistic analysis across multiple dimensions of these data-driven models such as type of CVD addressed, dataset characteristics, data input modalities, ML and DL algorithms (with a focus on DL), and aspects of Trustworthy AI like explainability, bias and ethical considerations. Additionally, within the analyzed dimensions, various challenges are identified. To these, we provide concrete recommendations, equipping other researchers with valuable insights to understand the current state of the field comprehensively.

13 October 2020 in Cancers
Verified
Journal Article
Open access
PDF file
MBMarco Bologna
Marco Bologna
VCValentina Corino
Valentina Corino
GCGiuseppina Calareso
Giuseppina Calareso
CTChiara Tenconi
Chiara Tenconi
SASalvatore Alfieri
Salvatore Alfieri
EOEster Orlandi
Ester Orlandi
Advanced stage nasopharyngeal cancer (NPC) shows highly variable treatment outcomes, suggesting the need for independent prognostic factors. This study aims at developing a magnetic resonance imaging (MRI)-based radiomic signature as a prognostic marker for different clinical endpoints in NPC patients from non-endemic areas. A total 136 patients with advanced NPC and available MRI imaging (T1-weighted and T2-weighted) were selected. For each patient, 2144 radiomic features were extracted from the main tumor and largest lymph node. A multivariate Cox regression model was trained on a subset of features to obtain a radiomic signature for overall survival (OS), which was also applied for the prognosis of other clinical endpoints. Validation was performed using 10-fold cross-validation. The added prognostic value of the radiomic features to clinical features and volume was also evaluated. The radiomics-based signature had good prognostic power for OS and loco-regional recurrence-free survival (LRFS), with C-index of 0.68 and 0.72, respectively. In all the cases, the addition of radiomics to clinical features improved the prognostic performance. Radiomic features can provide independent prognostic information in NPC patients from non-endemic areas.

30 August 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
VCValentina Corino
Valentina Corino
FSFrida Samdberg
Frida Samdberg
LMLuca T. Mainardi
Luca T. Mainardi
LSLeif Sornmo
Leif Sornmo
This paper introduces a model of the atrioventricular node function during atrial fibrillation (AF), and describes the related ECG-based estimation method. The proposed model is defined by parameters that characterize the arrival rate of atrial impulses, the probability of an impulse choosing either one of the two atrioventricular nodal pathways, the refractory periods of these pathways, and the prolongation of the refractory periods. These parameters are estimated from the RR intervals using maximum likelihood estimation, except for the shorter refractory period which is estimated from the RR interval Poincaré plot, and the mean arrival rate of atrial impulses by the AF frequency. Simulations indicated that 200-300 RR intervals are generally needed for the estimates to be accurate. The model was evaluated on 30-min ECG segments from 36 AF patients. The results showed that 88% of the segments can be accurately modeled when the estimated probability density function (PDF) and an empirical PDF were at least 80% in agreement. The model parameters were estimated during head-up tilt test to assess differences caused by sympathetic stimulation. Both refractory periods decreased as a result of stimulation, and the likelihood of an impulse choosing the pathway with the shorter refractory period increased.

29 June 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
MLMattia Loppini
Mattia Loppini
FGFrancesco Manlio Gambaro
Francesco Manlio Gambaro
KCKatia Chiappetta
Katia Chiappetta
GGGuido Grappiolo
Guido Grappiolo
Anna Maria BianchiAnna Maria Bianchi
Anna Maria Bianchi
VCValentina Corino
Valentina Corino
Background: Total hip arthroplasty (THA) follow-up is conventionally conducted with serial X-ray imaging in order to ensure the early identification of implant failure. The purpose of this study is to develop an automated radiographic failure detection system. Methods: 630 patients with THA were included in the study, two thirds of which needed total or partial revision for prosthetic loosening. The analysis is based on one antero-posterior and one lateral radiographic view obtained from each patient during routine post-surgery follow-up. After pre-processing for proper standardization, images were analyzed through a convolutional neural network (the DenseNet169 network), aiming to predict prosthesis failure. The entire dataset was divided in three subsets: training, validation, and test. These contained transfer learning and fine-tuning algorithms, based on the training dataset, and were implemented to adapt the DenseNet169 network to the specific data and clinical problem. Results: After the training procedures, in the test set, the classification accuracy was 0.97, the sensitivity 0.97, the specificity 0.97, and the ROC AUC was 0.99. Only five images were incorrectly classified. Seventy-four images were classified as failed, and eighty as non-failed with a probability >0.999. Conclusion: The proposed deep learning procedure can detect the loosening of the hip prosthesis with a very high degree of precision.