Objective: The present study addresses the problem of estimating the respiratory rate from the morphological ECG variations in the presence of atrial fibrillatory waves (f-waves). The significance of performing f-wave suppression before respiratory rate estimation is investigated. Methods: The performance of a novel approach to ECG-derived respiration, named “slope range” (SR) and designed particularly for operation in atrial fibrillation (AF), is compared to that of two well-known methods based on either R-wave angle (RA) or QRS loop rotation angle (LA). A novel rule is proposed for spectral peak selection in respiratory rate estimation. The suppression of f-waves is accomplished using signal- and noise-dependent QRS weighted averaging. The performance evaluation embraces real as well as simulated ECG signals acquired from patients with persistent AF; the estimation error of the respiratory rate is determined for both types of signals. Results: Using real ECG signals and reference respiratory signals, rate estimation without f-wave suppression resulted in a median error of 0.015 ± 0.021 Hz and 0.019 ± 0.025 Hz for SR and RA, respectively, whereas LA with f-wave suppression resulted in 0.034 ± 0.039 Hz. Using simulated signals, the results also demonstrate that f-wave suppression is superfluous for SR and RA, whereas it is essential for LA. Conclusion: The results show that SR offers the best performance as well as computational simplicity since f-wave suppression is not needed. Significance: The respiratory rate can be robustly estimated from the ECG in the presence of AF.
16 January 2008 in IEEE Transactions on Biomedical Engineering
A hidden Markov model (HMM) is employed to improve noise robustness when tracking the dominant frequency of atrial fibrillation (AF) in the electrocardiogram (ECG). Following QRST cancellation, a sequence of observed frequency states is obtained from the residual ECG, using the short-time Fourier transform. Based on the observed state sequence, the Viterbi algorithm retrieves the optimal state sequence by exploiting the state transition matrix, incorporating knowledge on AF characteristics, and the observation matrix, incorporating knowledge of the frequency estimation method and signal-to-noise ratio (SNR). The tracking method is evaluated with simulated AF signals to which noise, obtained from ECG recordings, has been added at different SNRs. The results show that the use of HMM improves performance considerably by reducing the rms error associated with frequency tracking: at 4-dB SNR, the rms error drops from 0.2 to 0.04 Hz.
10 February 2011 in IEEE Transactions on Biomedical Engineering
The problem of classifying short atrial fibrillatory segments in ambulatory ECG recordings as being either paroxysmal or persistent is addressed by investigating a robust approach to signal characterization. The method comprises preprocessing estimation of the dominant atrial frequency for the purpose of controlling the subbands of a filter bank, computation of the relative subband (harmonics) energy, and the subband sample entropy. Using minimum-error-rate classification of different feature vectors, a data set consisting of 24-h ambulatory recordings from 50 subjects with either paroxysmal (26) or persistent (24) atrial fibrillation (AF) was analyzed on a 10-s segment basis; a total of 212,196 segments were classified. The best performance in terms of area under the receiver operating characteristic curve was obtained for a feature vector defined by the subband sample entropy of the dominant atrial frequency and the relative harmonics energy, resulting in a value of 0.923, whereas that of the dominant atrial frequency was equal to 0.826. It is concluded that paroxysmal and persistent AFs can be discriminated from short segments with good accuracy at any time of an ambulatory recording.
30 August 2011 in IEEE Transactions on Biomedical Engineering
This paper introduces a model of the atrioventricular node function during atrial fibrillation (AF), and describes the related ECG-based estimation method. The proposed model is defined by parameters that characterize the arrival rate of atrial impulses, the probability of an impulse choosing either one of the two atrioventricular nodal pathways, the refractory periods of these pathways, and the prolongation of the refractory periods. These parameters are estimated from the RR intervals using maximum likelihood estimation, except for the shorter refractory period which is estimated from the RR interval Poincaré plot, and the mean arrival rate of atrial impulses by the AF frequency. Simulations indicated that 200-300 RR intervals are generally needed for the estimates to be accurate. The model was evaluated on 30-min ECG segments from 36 AF patients. The results showed that 88% of the segments can be accurately modeled when the estimated probability density function (PDF) and an empirical PDF were at least 80% in agreement. The model parameters were estimated during head-up tilt test to assess differences caused by sympathetic stimulation. Both refractory periods decreased as a result of stimulation, and the likelihood of an impulse choosing the pathway with the shorter refractory period increased.
28 February 2018 in IEEE Transactions on Biomedical Engineering
Objective: The detection and analysis of atrial fibrillation (AF) in the ECG is greatly influenced by signal quality. The present study proposes and evaluates a model-based f-wave signal quality index (SQI), denoted S, for use in the QRST-cancelled ECG signal. Methods:S is computed using a harmonic f-wave model, allowing for variation in frequency and amplitude. The properties of S are evaluated on both f-waves and P-waves using 378 12-lead ECGs, 1875 single-lead ECGs, and simulated signals. Results: S decreases monotonically when noise is added to f-wave signals, even for noise which overlaps spectrally with f-waves. Moreover, S is shown to be closely associated with the accuracy of AF frequency estimation, where S > 0.3 implies accurate estimation. When S is used as a measure of fwave presence, AF detection performance improves: the sensitivity increases from 97.0% to 98.1% and the specificity increases from 97.4% to 97.8% when compared to the reference detector. Conclusion: The proposed SQI represents a novel approach to assessing f-wave signal quality, as well as to determining whether f-waves are present. Significance: The use of S improves the detection of AF and benefits the analysis of noisy ECGs.
24 July 2012 in IEEE Reviews in Biomedical Engineering
Episodes of hypotension during hemodialysis treatment constitutes an important clinical problem which has received considerable attention in recent years. Despite the fact that numerous approaches to reducing the frequency of intradialytic hypotension (IDH) have been proposed and evaluated, the problem has not yet found a definitive solution-an observation which, in particular, applies to episodes of acute, symptomatic hypotension. This overview covers recent advances in methodology for predicting and preventing IDH. Following a brief overview of well-established hypotension-related variables, including blood pressure, blood temperature, relative blood volume, and bioimpedance, special attention is given to electrocardiographic and photoplethysmographic (PPG) variables and their significance for IDH prediction. It is concluded that cardiovascular variables which reflect heart rate variability, heart rate turbulence, and baroreflex sensitivity are important to explore in feedback control hemodialysis systems so as to improve their performance. The analysis of hemodialysis-related changes in PPG pulse wave properties hold considerable promise for improving prediction.