Ganesh R Naik

Prof. Ganesh R Naik

Marcs Institute For Brain, Behaviour & Development, Western Sydney University, Penrith, NSW 2751, Australia
+1
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2021 in Frontiers in Systems Neuroscience
Verified
Journal Article
Open access
PDF file
SSSimanto Saha
Simanto Saha
KMKhondaker A. Mamun
Khondaker A. Mamun
KAKhawza Ahmed
Khawza Ahmed
RMRaqibul Mostafa
Raqibul Mostafa
Ganesh R NaikGanesh R Naik
Ganesh R Naik
Mathias BaumertMathias Baumert
Mathias Baumert
Brain computer interfaces (BCI) provide a direct communication link between the brain and a computer or other external devices. They offer an extended degree of freedom either by strengthening or by substituting human peripheral working capacity and have potential applications in various fields such as rehabilitation, affective computing, robotics, gaming, and neuroscience. Significant research efforts on a global scale have delivered common platforms for technology standardization and help tackle highly complex and non-linear brain dynamics and related feature extraction and classification challenges. Time-variant psycho-neurophysiological fluctuations and their impact on brain signals impose another challenge for BCI researchers to transform the technology from laboratory experiments to plug-and-play daily life. This review summarizes state-of-the-art progress in the BCI field over the last decades and highlights critical challenges.

22 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Nawadita ParajuliNawadita Parajuli
Nawadita Parajuli
NSNeethu Sreenivasan
Neethu Sreenivasan
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
Mario CesarelliMario Cesarelli
Mario Cesarelli
SSSergio Savino
Sergio Savino
GGGaetano Gargiulo
Gaetano Gargiulo
Upper limb amputation is a condition that significantly restricts the amputees from performing their daily activities. The myoelectric prosthesis, using signals from residual stump muscles, is aimed at restoring the function of such lost limbs seamlessly. Unfortunately, the acquisition and use of such myosignals are cumbersome and complicated. Furthermore, once acquired, it usually requires heavy computational power to turn it into a user control signal. Its transition to a practical prosthesis solution is still being challenged by various factors particularly those related to the fact that each amputee has different mobility, muscle contraction forces, limb positional variations and electrode placements. Thus, a solution that can adapt or otherwise tailor itself to each individual is required for maximum utility across amputees. Modified machine learning schemes for pattern recognition have the potential to significantly reduce the factors (movement of users and contraction of the muscle) affecting the traditional electromyography (EMG)-pattern recognition methods. Although recent developments of intelligent pattern recognition techniques could discriminate multiple degrees of freedom with high-level accuracy, their efficiency level was less accessible and revealed in real-world (amputee) applications. This review paper examined the suitability of upper limb prosthesis (ULP) inventions in the healthcare sector from their technical control perspective. More focus was given to the review of real-world applications and the use of pattern recognition control on amputees. We first reviewed the overall structure of pattern recognition schemes for myo-control prosthetic systems and then discussed their real-time use on amputee upper limbs. Finally, we concluded the paper with a discussion of the existing challenges and future research recommendations.

19 February 2016 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Rifai ChaiRifai Chai
Rifai Chai
Ganesh R NaikGanesh R Naik
Ganesh R Naik
TNTuan Nghia Nguyen
Tuan Nghia Nguyen
SLSai Ho Ling
Sai Ho Ling
Yvonne TranYvonne Tran
Yvonne Tran
HNHung Nguyen
Hung Nguyen
This paper presents a two-class electroencephal-ography-based classification for classifying of driver fatigue (fatigue state versus alert state) from 43 healthy participants. The system uses independent component by entropy rate bound minimization analysis (ERBM-ICA) for the source separation, autoregressive (AR) modeling for the features extraction, and Bayesian neural network for the classification algorithm. The classification results demonstrate a sensitivity of 89.7%, a specificity of 86.8%, and an accuracy of 88.2%. The combination of ERBM-ICA (source separator), AR (feature extractor), and Bayesian neural network (classifier) provides the best outcome with a p-value <; 0.05 with the highest value of area under the receiver operating curve (AUC-ROC = 0.93) against other methods such as power spectral density as feature extractor (AUC-ROC = 0.81). The results of this study suggest the method could be utilized effectively for a countermeasure device for driver fatigue identification and other adverse event applications.

1 March 2022 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Open access
BLBastien Lechat
Bastien Lechat
Ganesh R NaikGanesh R Naik
Ganesh R Naik
ARAmy Reynolds
Amy Reynolds
AAAtqiya Aishah
Atqiya Aishah
HSHannah Scott
Hannah Scott
DEDanny J. Eckert
Danny J. Eckert
Rationale: Recent studies suggest that obstructive sleep apnea (OSA) severity can vary markedly from night to night, which may have important implications for diagnosis and management. Objectives: This study aimed to assess OSA prevalence from multinight in-home recordings and the impact of night-to-night variability in OSA severity on diagnostic classification in a large, global, nonrandomly selected community sample from a consumer database of people that purchased a novel, validated, under-mattress sleep analyzer. Methods: A total of 67,278 individuals aged between 18 and 90 years underwent in-home nightly monitoring over an average of approximately 170 nights per participant between July 2020 and March 2021. OSA was defined as a nightly mean apnea–hypopnea index (AHI) of more than 15 events/h. Outcomes were multinight global prevalence and likelihood of OSA misclassification from a single night’s AHI value. Measurements and Main Results: More than 11.6 million nights of data were collected and analyzed. OSA global prevalence was 22.6% (95% confidence interval, 20.9–24.3%). The likelihood of misdiagnosis in people with OSA based on a single night ranged between approximately 20% and 50%. Misdiagnosis error rates decreased with increased monitoring nights (e.g., 1-night F1-score = 0.77 vs. 0.94 for 14 nights) and remained stable after 14 nights of monitoring. Conclusions: Multinight in-home monitoring using novel, noninvasive under-mattress sensor technology indicates a global prevalence of moderate to severe OSA of approximately 20%, and that approximately 20% of people diagnosed with a single-night study may be misclassified. These findings highlight the need to consider night-to-night variation in OSA diagnosis and management.

15 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
V. RajinikanthV. Rajinikanth
V. Rajinikanth
ARAlex Noel Joseph Raj
Alex Noel Joseph Raj
PKPalani Thanaraj Krishnan
Palani Thanaraj Krishnan
Ganesh R NaikGanesh R Naik
Ganesh R Naik
Brain tumor (BT) is one of the brain abnormalities which arises due to various reasons. The unrecognized and untreated BT will increase the morbidity and mortality rates. The clinical level assessment of BT is normally performed using the bio-imaging technique, and MRI-assisted brain screening is one of the universal techniques. The proposed work aims to develop a deep learning architecture (DLA) to support the automated detection of BT using two-dimensional MRI slices. This work proposes the following DLAs to detect the BT: (i) implementing the pre-trained DLAs, such as AlexNet, VGG16, VGG19, ResNet50 and ResNet101 with the deep-features-based SoftMax classifier; (ii) pre-trained DLAs with deep-features-based classification using decision tree (DT), k nearest neighbor (KNN), SVM-linear and SVM-RBF; and (iii) a customized VGG19 network with serially-fused deep-features and handcrafted-features to improve the BT detection accuracy. The experimental investigation was separately executed using Flair, T2 and T1C modality MRI slices, and a ten-fold cross validation was implemented to substantiate the performance of proposed DLA. The results of this work confirm that the VGG19 with SVM-RBF helped to attain better classification accuracy with Flair (>99%), T2 (>98%), T1C (>97%) and clinical images (>98%).

17 September 2015 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
Ganesh R NaikGanesh R Naik
Ganesh R Naik
AAAli H. Al-Timemy
Ali H. Al-Timemy
HNHung Nguyen
Hung Nguyen
Surface electromyography (sEMG)-based pattern recognition studies have been widely used to improve the classification accuracy of upper limb gestures. Information extracted from multiple sensors of the sEMG recording sites can be used as inputs to control powered upper limb prostheses. However, usage of multiple EMG sensors on the prosthetic hand is not practical and makes it difficult for amputees due to electrode shift/movement, and often amputees feel discomfort in wearing sEMG sensor array. Instead, using fewer numbers of sensors would greatly improve the controllability of prosthetic devices and it would add dexterity and flexibility in their operation. In this paper, we propose a novel myoelectric control technique for identification of various gestures using the minimum number of sensors based on independent component analysis (ICA) and Icasso clustering. The proposed method is a model-based approach where a combination of source separation and Icasso clustering was utilized to improve the classification performance of independent finger movements for transradial amputee subjects. Two sEMG sensor combinations were investigated based on the muscle morphology and Icasso clustering and compared to Sequential Forward Selection (SFS) and greedy search algorithm. The performance of the proposed method has been validated with five transradial amputees, which reports a higher classification accuracy ( >95%). The outcome of this study encourages possible extension of the proposed approach to real time prosthetic applications.