Yi Xu

Dr. Yi Xu

Institute of Mechanics, Chinese Academy of Science, Beijing 100190, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2023 in Metals
Verified
Journal Article
Open access
PDF file
Liuhe LiLiuhe Li
Liuhe Li
Liuhe LiLiuhe Li
Liuhe Li
DLDuoduo Li
Duoduo Li
LTLing Tang
Ling Tang
YLYang Luo
Yang Luo
XXXiaolei Xu
Xiaolei Xu
Erosion seriously threatens the safety of high-speed rotating mechanical components in very harsh service environments, particularly for lightweight titanium alloy matrix material. In order to improve the erosion resistance of titanium alloy, TiAlSiN coatings with different phase compositions are deposited on TC6 titanium alloy using a high-power pulse magnetron sputtering discharge (HPPMS) system under various discharge voltages. The componential and microstructural evolution as well as mechanical properties of the TiAlSiN coatings are evaluated by X-ray diffraction, scanning electron microscopy, and nanoindentation, respectively. The erosion performance relative to titanium alloy is investigated by a sand blasting tester. With the increase in discharge voltage from −500 to −600 V, the peak of discharge current increases from 105 to 225 A. The prepared TiAlSiN coatings show a shift of the preferred crystallographic orientation from (220) to (200), but all of them have a dense nanocomposite structure. Their hardness (H) and elastic modulus (E) gradually increase before decreasing, arriving at maximum values of 35.34 and 360.5 GPa at −570 V. The erosion resistance of the TiAlSiN coatings dependent on the discharge voltage is consistent with the H/E ratio change. The TiAlSiN coatings prepared at −560 V exhibit the optimal erosion resistance, which is 15 times that of the TC6 substrate. The erosion behavior of the coatings is positively correlated with their hardness and toughness. Adjusting the discharge voltage of the HPPMS pulse is finally proved to be an effective way of tailoring the coating phase compositions to improve the erosion resistance of titanium alloy.

28 June 2020 in Coatings
Verified
Journal Article
Open access
PDF file
GLGuang Li
Guang Li
YXYi Xu
Yi Xu
YXYuan Xia
Yuan Xia
A pulsed-dc (direct current) magnetron sputtering with a plasma emission monitor (PEM) system was applied to synthesize Cr-containing hydrogenated amorphous diamond-like carbon (Cr-DLC) films using a large-size industrial Cr target. The plasma emission intensity of a Cr atom at 358 nm wavelength was characterized by optical emission spectrometer (OES). C2H2 gas flow rate was precisely adjusted to obtain a stable plasma emission intensity. The relationships between Cr atom plasma emission intensity and the element concentration, cross-sectional morphology, deposition rate, microstructure, mechanical properties, and tribological properties of Cr-DLC films were investigated. Scanning electron microscope and Raman spectra were employed to analyze the chemical composition and microstructure, respectively. The mechanical and tribological behaviors were characterized and analyzed by using the nano-indentation, scratch test instrument, and ball-on-disk reciprocating friction/wear tester. The results indicate that the PEM system was successfully used in magnetron sputtering for a more stable Cr-DLC deposition process.

24 November 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Guodong LiGuodong Li
Guodong Li
FMFei Ma
Fei Ma
ZLZhijie Li
Zhijie Li
YXYi Xu
Yi Xu
FGFangyuan Gao
Fangyuan Gao
YXYuan Xia
Yuan Xia
In this study, plasma electrolytic oxidation (PEO) was performed on Al and AlSi substrates using a pulsed direct current (DC) power source. The coating process was carried out in a Na2SiO3 electrolyte with the systematic change of pulse frequency (50–1400 Hz). The surface characteristics of the coatings were examined using scanning electron microscopy (SEM). The phase structure was characterized using X-ray diffraction (XRD). A differential scanning calorimeter (DSC) and a laser flash apparatus (LFA) were employed to test heat capacity and heat conductivity, respectively. Results showed that as the discharge frequency increased, the thermal physical properties of Al-PEO and AlSi-PEO coatings changed in different ways. At a high frequency, Al-PEO coatings had low porosity and were closed-pore structured whereas AlSi-PEO coatings had high porosity and large-size open-pore structures could be observed on their surfaces due to concentrated discharges. Based on these findings, it was found that the thermal productivity of coatings is closely correlated with the open-/closed-pore structure instead of porosity. PEO coatings with low heat capacity or low heat conductivity could be obtained with a controlled frequency.

13 June 2026 in Coatings
Verified
Journal Article
Open access
PDF file
ZXZhao Xinjie
Zhao Xinjie
LHLei He
Lei He
YXYi Xu
Yi Xu
Guodong LiGuodong Li
Guodong Li
In view of the fact that there are few reports on the preparation of NbC coating by high-power pulsed magnetron sputtering (HiPIMS) technology. In this study, the effects of NbC interlayer thickness on the microstructure, corrosion resistance and electrical conductivity of Nb/NbC/C multilayer coatings for proton exchange membrane fuel cell (PEMFC) bipolar plates were studied by using the high ionization characteristics of HiPIMS technology. A series of Nb/NbC/C multilayer coatings with varying NbC interlayer thicknesses was deposited via HiPIMS by modulating the deposition time (20, 40, and 60 min). The microstructure and properties of the coatings were characterized using scanning electron microscopy (SEM), Raman spectroscopy, interfacial contact resistance (ICR), and corrosion current, among other methods. The results indicate that as the NbC interlayer thickness increases, the total coating thickness increases from 0.43 μm to 1.42 μm. All coatings exhibit a uniform and dense microstructure lacking typical coarse columnar structures. Raman and XPS analyses show that the ID/IG ratio increases from 1.98 to 4.04, indicating an increase in sp2-hybridized bond content and a decrease in sp3 content. At a deposition time of 60 min, the coating achieved optimal performance, yielding a critical load (Lc1) of 31.9 N, the lowest average friction coefficient (0.27), the minimum corrosion current density, and an interfacial contact resistance of 7.5 mΩ·cm2. These results demonstrate that the NbC interlayer thickness significantly governs the structure and properties of the Nb/NbC/C multilayer coatings. Specifically, an appropriate increase in the NbC interlayer thickness optimizes the sp2/sp3 hybrid bond ratio, thereby enhancing the overall coating performance.