Svitozar Serkez

Dr. Svitozar Serkez

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2015 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
DRD. Ratner
D. Ratner
RAR. Abela
R. Abela
JAJ. Amann
J. Amann
CBC. Behrens
C. Behrens
DBD. Bohler
D. Bohler
JWJ. Wu
J. Wu
The Linac Coherent Light Source has added a self-seeding capability to the soft x-ray range using a grating monochromator system. We report the demonstration of soft x-ray self-seeding with a measured resolving power of 2000–5000, wavelength stability of 10−4, and an increase in peak brightness by a factor of 2–5 across the photon energy range of 500–1000 eV. By avoiding the need for a monochromator at the experimental station, the self-seeded beam can deliver as much as 50-fold higher brightness to users.

16 October 2023 in Nature Photonics
Verified
Journal Article
Open access
PDF file
SLShan Liu
Shan Liu
Christian GrechChristian Grech
Christian Grech
MGMarc Guetg
Marc Guetg
SKSuren Karabekyan
Suren Karabekyan
VKVitali Kocharyan
Vitali Kocharyan
GGGianluca Geloni
Gianluca Geloni
High-resolution X-ray spectroscopy in the sub-nanosecond to femtosecond time range requires ultrashort X-ray pulses and a spectral X-ray flux considerably larger than that presently available. X-ray free-electron laser (XFEL) radiation from hard X-ray self-seeding (HXRSS) setups has been demonstrated in the past and offers the necessary peak flux properties. So far, these systems could not provide high repetition rates enabling a high average flux. We report the results for a cascaded HXRSS system installed at the European XFEL, currently the only operating high-repetition-rate hard X-ray XFEL facility worldwide. A high repetition rate, combined with HXRSS, allows the generation of millijoule-level pulses in the photon energy range of 6–14 keV with a bandwidth of around 1 eV (corresponding to about 1 mJ eV–1 peak spectral density) at the rate of ten trains per second, each train including hundreds of pulses arriving at a megahertz repetition rate. At 2.25 MHz repetition rate and photon energies in the 6–7 keV range, we observed and characterized the heat-load effects on the HXRSS crystals, substantially altering the spectra of subsequent X-ray pulses. We demonstrated that our cascaded self-seeding scheme reduces this detrimental effect to below the detection level. This opens up exciting new possibilities in a wide range of scientific fields employing ultrafast X-ray spectroscopy, scattering and imaging techniques.

9 January 2018 in Journal of Optics
Verified
Journal Article
Closed access
PDF file
SSSvitozar Serkez
Svitozar Serkez
GGGianluca Geloni
Gianluca Geloni
STSergey Tomin
Sergey Tomin
GFGuangyao Feng
Guangyao Feng
EGE V Gryzlova
E V Gryzlova
MMMichael Meyer
Michael Meyer
The generation of attosecond, highbrightness x-ray pulses is a matter of great interest given their applications in the study of ultra-fast processes. In recent years, the production of x-ray pulses of high brightness, both in the soft and in the hard x-ray range, has been enabled by x-ray free-electron lasers (XFELs). In contrast to conventional quantum lasers, XFELs are based on the use of an ultra-relativistic electron beam as gain medium. They often work in the self-amplified spontaneous emission (SASE) regime, which provides pulses of duration down to a few femtoseconds, composed of several longitudinal modes. In order to further decrease the duration of these pulses, special methods need to be implemented. In this paper we review available methods, with particular focus on the x-ray laser-enhanced attosecond pulse generation, which is one of the most promising techniques. We illustrate the method using the SASE3 soft x-ray undulator of the European XFEL facility as a case study, emphasizing the importance of high-repetition rate attosecond x-ray pulses. The expected attosecond-level radiation output is used for simulations of sequential ionization processes in atoms in the case of ionization in the soft x-ray regime, demonstrating the importance of this opportunity for the user community.

1 June 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
WLW. Lu
W. Lu
BFB. Friedrich
B. Friedrich
TNT. Noll
T. Noll
KZK. Zhou
K. Zhou
JHJ. Hallmann
J. Hallmann
SES. Eisebitt
S. Eisebitt
A hard X-ray Split-and-Delay Line (SDL) under construction for the Materials Imaging and Dynamics station at the European X-Ray Free-Electron Laser (XFEL) is presented. This device aims at providing pairs of X-ray pulses with a variable time delay ranging from −10 ps to 800 ps in a photon energy range from 5 to 10 keV for photon correlation and X-ray pump-probe experiments. A custom designed mechanical motion system including active feedback control ensures that the high demands for stability and accuracy can be met and the design goals achieved. Using special radiation configurations of the European XFEL’s SASE-2 undulator (SASE: Self-Amplified Spontaneous Emission), two-color hard x-ray pump-probe schemes with varying photon energy separations have been proposed. Simulations indicate that more than 109 photons on the sample per pulse-pair and up to about 10% photon energy separation can be achieved in the hard X-ray region using the SDL.

15 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSSvitozar Serkez
Svitozar Serkez
WDWinfried Decking
Winfried Decking
LFLars Froehlich
Lars Froehlich
NGNatalia Gerasimova
Natalia Gerasimova
JGJan Gruenert
Jan Gruenert
GGGianluca Geloni
Gianluca Geloni
X-ray pump/X-ray probe applications are made possible at X-ray Free Electron Laser (XFEL) facilities by generating two X-ray pulses with different wavelengths and controllable temporal delay. In order to enable this capability at the European XFEL, an upgrade project to equip the soft X-ray SASE3 beamline with a magnetic chicane is underway. In the present paper we describe the status of the project, its scientific focus and expected performance, including start-to-end simulations of the photon beam transport up to the sample, as well as recent experimental results demonstrating two-color lasing at photon energies of 805 eV + 835 eV and 910 eV + 950 eV. Additionally, we discuss methods to analyze the spectral properties and the intensity of the generated radiation to provide on-line diagnostics for future user experiments.
1

22 March 2012 in Physical Review Special Topics - Accelerators and Beams
Verified
Journal Article
Open access
CBC. Behrens
C. Behrens
NGN. Gerasimova
N. Gerasimova
CGCh. Gerth
Ch. Gerth
BSB. Schmidt
B. Schmidt
ESEvgeny Schneidmiller
Evgeny Schneidmiller
MYM. V. Yurkov
M. V. Yurkov
The successful operation of x-ray free-electron lasers (FELs), like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH), makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse durations need to be known and tunable. This can be achieved by controlling the FEL driving electron beams, and high-resolution longitudinal electron beam diagnostics can be utilized to provide constraints on the expected FEL photon pulse durations. In this paper, we present comparative measurements of soft x-ray pulse durations and electron bunch lengths at FLASH. The soft x-ray pulse durations were measured by FEL radiation pulse energy statistics and compared to electron bunch lengths determined by frequency-domain spectroscopy of coherent transition radiation in the terahertz range and time-domain longitudinal phase space measurements. The experimental results, theoretical considerations, and simulations show that high-resolution longitudinal electron beam diagnostics provide reasonable constraints on the expected FEL photon pulse durations. In addition, we demonstrated the generation of soft x-ray pulses with durations below 50 fs (FWHM) after the implementation of the new uniform electron bunch compression scheme used at FLASH. DOI: http://dx.doi.org/10.1103/PhysRevSTAB.15.030707 Published by the American Physical Society under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. Published by the American Physical Society