Natalia Gerasimova

Natalia Gerasimova

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSSvitozar Serkez
Svitozar Serkez
WDWinfried Decking
Winfried Decking
LFLars Froehlich
Lars Froehlich
NGNatalia Gerasimova
Natalia Gerasimova
JGJan Gruenert
Jan Gruenert
GGGianluca Geloni
Gianluca Geloni
X-ray pump/X-ray probe applications are made possible at X-ray Free Electron Laser (XFEL) facilities by generating two X-ray pulses with different wavelengths and controllable temporal delay. In order to enable this capability at the European XFEL, an upgrade project to equip the soft X-ray SASE3 beamline with a magnetic chicane is underway. In the present paper we describe the status of the project, its scientific focus and expected performance, including start-to-end simulations of the photon beam transport up to the sample, as well as recent experimental results demonstrating two-color lasing at photon energies of 805 eV + 835 eV and 910 eV + 950 eV. Additionally, we discuss methods to analyze the spectral properties and the intensity of the generated radiation to provide on-line diagnostics for future user experiments.
1

23 August 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
NGNatalia Gerasimova
Natalia Gerasimova
DCD. La Civita
D. La Civita
LSL. Samoylova
L. Samoylova
MVMaurizio Vannoni
Maurizio Vannoni
RVR. Villanueva
R. Villanueva
ASA. Scherz
A. Scherz
The SASE3 soft X-ray beamline at the European XFEL has been designed and built to provide experiments with a pink or monochromatic beam in the photon energy range 250–3000 eV. Here, the focus is monochromatic operation of the SASE3 beamline, and the design and performance of the SASE3 grating monochromator are reported. The unique capability of a free-electron laser source to produce short femtosecond pulses of a high degree of coherence challenges the monochromator design by demanding control of both photon energy and temporal resolution. The aim to transport close to transform-limited pulses poses very high demands on the optics quality, in particular on the grating. The current realization of the SASE3 monochromator is discussed in comparison with optimal design performance. At present, the monochromator operates with two gratings: the low-resolution grating is optimized for time-resolved experiments and allows for moderate resolving power of about 2000–5000 along with pulse stretching of a few to a few tens of femtoseconds RMS, and the high-resolution grating reaches a resolving power of 10 000 at the cost of larger pulse stretching.

29 July 2024 in Nature Physics
Verified
Journal Article
Open access
PDF file
LMLaurent Mercadier
Laurent Mercadier
ABAndrei Benediktovitch
Andrei Benediktovitch
ŠKŠpela Krušič
Špela Krušič
JKJoshua J. Kas
Joshua J. Kas
JSJustine Schlappa
Justine Schlappa
NRNina Rohringer
Nina Rohringer
Warm dense matter is at the boundary between a plasma and a condensed phase and plays a role in astrophysics, planetary science and inertial confinement fusion research. However, its electronic structure and ionic structure upon irradiation with strong laser pulses remain poorly understood. Here, we use an intense and ultrafast X-ray free-electron laser pulse to simultaneously create and characterize warm dense copper using L-edge X-ray absorption spectroscopy over a large irradiation intensity range. Below a pulse intensity of 1015 W cm−2, an absorption peak below the L edge appears, originating from transient depletion of the 3d band. This peak shifts to lower energy with increasing intensity, indicating the movement of the 3d band upon strong X-ray excitation. At higher intensities, substantial ionization and collisions lead to the transition from reverse saturable absorption to saturable absorption of the X-ray free-electron laser pulse, two nonlinear effects that hold promise for X-ray pulse-shaping. We employ theoretical calculations that combine a model based on kinetic Boltzmann equations with finite-temperature real-space density-functional theory to interpret these observations. The results can be used to benchmark non-equilibrium models of electronic structure in warm dense matter.

23 December 2022 in Physical Review B
Verified
Journal Article
Open access
PDF file
NHNanna Zhou Hagström
Nanna Zhou Hagström
RJRahul Jangid
Rahul Jangid
MMMeera Madhavi
Meera Madhavi
DTDiego Turenne
Diego Turenne
JBJeffrey A. Brock
Jeffrey A. Brock
EIEzio Iacocca
Ezio Iacocca
Femtosecond optical pumping of magnetic materials has been used to achieve ultrafast switching and recently to nucleate symmetry-broken magnetic states. However, when the magnetic order parameter already presents a broken-symmetry state, such as a domain pattern, the dynamics are poorly understood and consensus remains elusive. Here, we resolve the controversies in the literature by studying the ultrafast response of magnetic domain patterns with varying degrees of translation symmetry with ultrafast x-ray resonant scattering. A data analysis technique is introduced to disentangle the isotropic and anisotropic components of the x-ray scattering. We find that the scattered intensity exhibits a radial shift restricted to the isotropic component, indicating that the far-from-equilibrium magnetization dynamics are intrinsically related to the spatial features of the domain pattern. Our results suggest alternative pathways for the spatiotemporal manipulation of magnetism via far-from-equilibrium dynamics and by carefully tuning the ground-state magnetic textures.

20 February 2023 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
LGLoïc Le Guyader
Loïc Le Guyader
AEAndrea Eschenlohr
Andrea Eschenlohr
MBMartin Beye
Martin Beye
WSWilliam Schlotter
William Schlotter
FDFlorian Döring
Florian Döring
ASAndreas Scherz
Andreas Scherz
Femtosecond transient soft X-ray absorption spectroscopy (XAS) is a very promising technique that can be employed at X-ray free-electron lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here, a dedicated setup for soft X-rays available at the Spectroscopy and Coherent Scattering (SCS) instrument at the European X-ray Free-Electron Laser (European XFEL) is presented. It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot by shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, an imaging detector capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst is employed, and allows a photon-shot-noise-limited sensitivity to be approached. The setup and its capabilities are reviewed as well as the online and offline analysis tools provided to users.

1 January 2025 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
JSJustine Schlappa
Justine Schlappa
GGGiacomo Ghiringhelli
Giacomo Ghiringhelli
BKBenjamin E. Van Kuiken
Benjamin E. Van Kuiken
MTMartin Teichmann
Martin Teichmann
piter miedemapiter miedema
piter miedema
AFAlexander Föhlisch
Alexander Föhlisch
Resonant inelastic X-ray scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. Also, in pump–probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high-repetition-rate pulsed X-ray sources like the European XFEL. The Heisenberg RIXS instrument is designed for RIXS experiments in the soft X-ray range with energy resolution approaching the Fourier and the Heisenberg limits. It is based on a spherical grating with variable line spacing and a position-sensitive 2D detector. Initially, two gratings were installed to adequately cover the whole photon energy range. With optimized spot size on the sample and small pixel detector the energy resolution can be better than 40 meV (90 meV) at any photon energy below 1000 eV with the high-resolution (high-transmission) grating. At the SCS instrument of the European XFEL the spectrometer can be easily positioned thanks to air pads on a high-quality floor, allowing the scattering angle to be continuously adjusted over the 65–145° range. It can be coupled to two different sample interaction chambers, one for liquid jets and one for solids, each state-of-the-art equipped and compatible for optical laser pumping in collinear geometry. The measured performances, in terms of energy resolution and count rate on the detector, closely match design expectations. The Heisenberg RIXS instrument has been open to public users since the summer of 2022.