Jan Gruenert

Dr. Jan Gruenert

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Thomas TschentscherThomas Tschentscher
Thomas Tschentscher
Christian BresslerChristian Bressler
Christian Bressler
JGJan Gruenert
Jan Gruenert
AMAnders Madsen
Anders Madsen
AMAdrian Mancuso
Adrian Mancuso
UZUlf Zastrau
Ulf Zastrau
European XFEL is a free-electron laser (FEL) user facility providing soft and hard X-ray FEL radiation to initially six scientific instruments. Starting user operation in fall 2017 European XFEL will provide new research opportunities to users from science domains as diverse as physics, chemistry, geo- and planetary sciences, materials sciences or biology. The unique feature of European XFEL is the provision of high average brilliance in the soft and hard X-ray regime, combined with the pulse properties of FEL radiation of extreme peak intensities, femtosecond pulse duration and high degree of coherence. The high average brilliance is achieved through acceleration of up to 27,000 electron bunches per second by the super-conducting electron accelerator. Enabling the usage of this high average brilliance in user experiments is one of the major instrumentation drivers for European XFEL. The radiation generated by three FEL sources is distributed via long beam transport systems to the experiment hall where the scientific instruments are located side-by-side. The X-ray beam transport systems have been optimized to maintain the unique features of the FEL radiation which will be monitored using build-in photon diagnostics. The six scientific instruments are optimized for specific applications using soft or hard X-ray techniques and include integrated lasers, dedicated sample environment, large area high frame rate detector(s) and computing systems capable of processing large quantities of data.

5 March 2018 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
NHN. Hartmann
N. Hartmann
GHG. Hartmann
G. Hartmann
RHR. Heider
R. Heider
MWM. S. Wagner
M. S. Wagner
MIM. Ilchen
M. Ilchen
Wolfram HelmlWolfram Helml
Wolfram Helml

9 May 2016 in Nature Photonics
Verified
Journal Article
Closed access
ALAlberto A. Lutman
Alberto A. Lutman
JMJames P. MacArthur
James P. MacArthur
MIMarkus Ilchen
Markus Ilchen
ALAnton O. Lindahl
Anton O. Lindahl
JBJens Buck
Jens Buck
HNHeinz-Dieter Nuhn
Heinz-Dieter Nuhn

4 June 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
TMTheophilos Maltezopoulos
Theophilos Maltezopoulos
FDFlorian Dietrich
Florian Dietrich
WFWolfgang Freund
Wolfgang Freund
UJUlf Fini Jastrow
Ulf Fini Jastrow
AKAndreas Koch
Andreas Koch
JGJan Gruenert
Jan Gruenert

15 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSSvitozar Serkez
Svitozar Serkez
WDWinfried Decking
Winfried Decking
LFLars Froehlich
Lars Froehlich
NGNatalia Gerasimova
Natalia Gerasimova
JGJan Gruenert
Jan Gruenert
GGGianluca Geloni
Gianluca Geloni
X-ray pump/X-ray probe applications are made possible at X-ray Free Electron Laser (XFEL) facilities by generating two X-ray pulses with different wavelengths and controllable temporal delay. In order to enable this capability at the European XFEL, an upgrade project to equip the soft X-ray SASE3 beamline with a magnetic chicane is underway. In the present paper we describe the status of the project, its scientific focus and expected performance, including start-to-end simulations of the photon beam transport up to the sample, as well as recent experimental results demonstrating two-color lasing at photon energies of 805 eV + 835 eV and 910 eV + 950 eV. Additionally, we discuss methods to analyze the spectral properties and the intensity of the generated radiation to provide on-line diagnostics for future user experiments.
1

21 February 2023 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
PRPatrick Rauer
Patrick Rauer
WDWinfried Decking
Winfried Decking
DLDirk Lipka
Dirk Lipka
DTDaniel Thoden
Daniel Thoden
TWTorsten Wohlenberg
Torsten Wohlenberg
JRJörg Rossbach
Jörg Rossbach
In this article, the concept of a recently funded R&D project for the installation of a proof-of-concept cavity-based x-ray free electron laser (CBXFEL) demonstrator experiment at the European XFEL facility is presented, with the first results expected in 2024. It is composed of an x-ray cavity design in backscattering geometry with a 133 m round trip length using cryogenically cooled diamond crystals. It employs the concept of retroreflection to reduce the sensitivity to vibrations. The FEL radiation is produced in four undulator segments of 20 m total length. Simulations at 16 GeV beam energy and 250 pC bunch charge show that the expected x-ray pulses in saturation surpass state-of-the-art x-ray sources considering spectral flux and three-dimensional coherence. However, the stability of the proof of concept setup is severely challenged by the finite thermal transport in the diamond crystals. Therefore, suitable measures such as cooling the crystals to 70 K are explained in this paper and additional ones will have to be developed in the course of this project.