Jose R. Huerta-Rosales

Dr. Jose R. Huerta-Rosales

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JHJose R. Huerta-Rosales
Jose R. Huerta-Rosales
David Granados-liebermanDavid Granados-lieberman
David Granados-lieberman
AGARTURO GARCIA-PEREZ
ARTURO GARCIA-PEREZ
DCDavid Camarena-Martinez
David Camarena-Martinez
Juan P. Amezquita-SanchezJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
One of the most critical devices in an electrical system is the transformer. It is continuously under different electrical and mechanical stresses that can produce failures in its components and other electrical network devices. The short-circuited turns (SCTs) are a common winding failure. This type of fault has been widely studied in literature employing the vibration signals produced in the transformer. Although promising results have been obtained, it is not a trivial task if different severity levels and a common high-level noise are considered. This paper presents a methodology based on statistical time features (STFs) and support vector machines (SVM) to diagnose a transformer under several SCTs conditions. As STFs, 19 indicators from the transformer vibration signals are computed; then, the most discriminant features are selected using the Fisher score analysis, and the linear discriminant analysis is used for dimension reduction. Finally, a support vector machine classifier is employed to carry out the diagnosis in an automatic way. Once the methodology has been developed, it is implemented on a field-programmable gate array (FPGA) to provide a system-on-a-chip solution. A modified transformer capable of emulating different SCTs severities is employed to validate and test the methodology and its FPGA implementation. Results demonstrate the effectiveness of the proposal for diagnosing the transformer condition as an accuracy of 96.82% is obtained.

13 April 2020 in Mathematics
Verified
Journal Article
Open access
PDF file
JHJose R. Huerta-Rosales
Jose R. Huerta-Rosales
David Granados-liebermanDavid Granados-lieberman
David Granados-lieberman
Juan P. Amezquita-SanchezJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
DCDavid Camarena-Martinez
David Camarena-Martinez
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
Transformers are vital and indispensable elements in electrical systems, and therefore, their correct operation is fundamental; despite being robust electrical machines, they are susceptible to present different types of faults during their service life. Although there are different faults, the fault of short-circuited turns (SCTs) has attracted the interest of many researchers around the world since the windings in a transformer are one of the most vulnerable parts. In this regard, several works in literature have analyzed the vibration signals that generate a transformer as a source of information to carry out fault diagnosis; however this analysis is not an easy task since the information associated with the fault is embedded in high level noise. This problem becomes more difficult when low levels of fault severity are considered. In this work, as the main contribution, the nonlinear mode decomposition (NMD) method is investigated as a potential signal processing technique to extract features from vibration signals, and thus, detect SCTs in transformers, even in early stages, i.e., low levels of fault severity. Also, the instantaneous root mean square (RMS) value computed using the Hilbert transform is proposed as a fault indicator, demonstrating to be sensitive to fault severity. Finally, a fuzzy logic system is developed for automatic fault diagnosis. To test the proposal, a modified transformer representing diverse levels of SCTs is used. These levels consist of 0 (healthy condition), 5, 10, 15, 20, and 25 SCTs. Results demonstrate the capability of the proposal to extract features from vibration signals and perform automatic fault diagnosis.

10 November 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
David Granados-liebermanDavid Granados-lieberman
David Granados-lieberman
JHJose R. Huerta-Rosales
Jose R. Huerta-Rosales
JGJose L. Gonzalez-Cordoba
Jose L. Gonzalez-Cordoba
Juan P. Amezquita-SanchezJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
DCDavid Camarena-Martinez
David Camarena-Martinez
Transformers are vital elements in electrical networks, but they are prone to various faults throughout their service life. Among these, a winding short-circuit fault is of particular concern to researchers, as it is a crucial and vulnerable component of the transformers. Therefore, if this fault is not addressed at an early stage, it can increase costs for users and affect industrial processes as well as other electrical machines. In recent years, the analysis of vibration signals has emerged as one of the most promising solutions for detecting faults in transformers. Nonetheless, it is not a straightforward process because of the nonstationary properties of the vibration signals and their high-level noise, as well as their different features when the transformer operates under different conditions. Based on the previously mentioned points, the motivation of this work is to contribute a methodology that can detect different severities of short-circuited turns (SCTs) in transformers in both transient and steady-state operating regimes using vibration signals. The proposed approach consists of a wavelet-based denoising stage, a short-time Fourier transform (STFT)-based analysis stage for the transient state, a Fourier transform (FT)-based analysis stage for the steady-state, the application of two fault indicators, i.e., the energy index and the total harmonic distortion index, and two neural networks for automatic diagnosis. To evaluate the effectiveness of the proposed methodology, a modified transformer is used to experimentally reproduce different levels of SCTs, i.e., 0-healthy, 5, 10, 15, 20, 25, and 30 SCTs, in a controlled way. The obtained results show that the proposed approach can detect the fault condition, starting from an initial stage for consolidation and a severe stage to accurately assess the fault severity, achieving accuracy values of 90%.

1 December 2022 in Electronics
Verified
Journal Article
Open access
PDF file
OCOmar Trejo Chavez
Omar Trejo Chavez
Juan P. Amezquita-SanchezJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
JHJose R. Huerta-Rosales
Jose R. Huerta-Rosales
LMLuis A. Morales-Hernández
Luis A. Morales-Hernández
ICIrving Cruz-Albarran
Irving Cruz-Albarran
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
Knee injury is a common health problem that affects both people who practice sports and those who do not do it. The high prevalence of knee injuries produces a considerable impact on the health-related life quality of patients. For this reason, it is essential to develop procedures for an early diagnosis, allowing patients to receive timely treatment for preventing and correcting knee injuries. In this regard, this paper presents, as main contribution, a methodology based on infrared thermography (IT) and convolutional neural networks (CNNs) to automatically differentiate between a healthy knee and an injured knee, being an alternative tool to help medical specialists. In general, the methodology consists of three steps: (1) database generation, (2) image processing, and (3) design and validation of a CNN for automatically identifying a patient with an injured knee. In the image-processing stage, grayscale images, equalized images, and thermal images are obtained as inputs for the CNN, where 98.72% of accuracy is obtained by the proposed method. To test its robustness, different infrared images with changes in rotation angle and different brightness levels (i.e., possible conditions at the time of imaging) are used, obtaining 97.44% accuracy. These results demonstrate the effectiveness and robustness of the proposal for differentiating between a patient with a healthy knee and an injured knee, having the advantages of using a fast, low-cost, innocuous, and non-invasive technology.

26 March 2024 in Electronics
Verified
Journal Article
Open access
PDF file
DCDavid Camarena-Martinez
David Camarena-Martinez
JHJose R. Huerta-Rosales
Jose R. Huerta-Rosales
Juan P. Amezquita-SanchezJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
David Granados-liebermanDavid Granados-lieberman
David Granados-lieberman
JOJuan C. Olivares-Glavan
Juan C. Olivares-Glavan
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
Transformers are key elements in electrical systems. Although they are robust machines, different faults can appear due to their inherent operating conditions, e.g., the presence of different electrical and mechanical stresses. Among the different elements that compound a transformer, the winding is one of the most vulnerable parts, where the damage of turn-to-turn short circuits is one of the most studied faults since low-level damage (i.e., a low number of short-circuited turns—SCTs) can lead to the overall fault of the transformer; therefore, early fault detection has become a fundamental task. In this regard, this paper presents a machine learning-based method to diagnose SCTs in the transformer windings by using their vibrational response. In general, the vibration signals are firstly decomposed by means of the variational mode decomposition method, where a comparison with the empirical mode decomposition (EMD) method and the ensemble empirical mode decomposition (EEMD) method is also carried out. Then, entropy, energy, and kurtosis indices are obtained from each decomposition as fault indicators, where both the combination of features and the dimensionality reduction by using the principal component analysis (PCA) method are analyzed for the global effectiveness improvement and the computational burden reduction. Finally, a pattern recognition algorithm based on artificial neural networks (ANNs) is used for automatic fault detection. The obtained results show 100% effectiveness in detecting seven fault conditions, i.e., 0 (healthy), 5, 10, 15, 20, 25, and 30 SCTs.

15 August 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JHJose R. Huerta-Rosales
Jose R. Huerta-Rosales
JOJuan C. Olivares-Glavan
Juan C. Olivares-Glavan
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
RERafael Escarela-Perez
Rafael Escarela-Perez
IRIvan Abel Hernandez Robles
Ivan Abel Hernandez Robles
David Granados-liebermanDavid Granados-lieberman
David Granados-lieberman
In power systems, transformers are fundamental components for ensuring efficient voltage regulation and distribution. Despite their robustness, these electric machines are prone to various faults, with short-circuited turns (SCTs) being one of the most common. Such faults can lead to increased vibrations, overheating, and eventual failure. To accurately diagnose these issues, vibration signature analysis has become a powerful and essential tool, enhancing preventive maintenance and minimizing downtime. Since frequency domain-based vibration signature analysis provides valuable insights into the condition of transformers, developing a model that generates the vibration frequency content of transformers under different operating conditions will be crucial for testing and enhancing diagnostic techniques. In this context, this article advances the state of the art by presenting an artificial neural network (ANN)-based experimental vibration frequency model, tested in a 1.5-kVA dry-type transformer under various conditions: different degrees of SCTs, ranging from 0 (healthy condition) to 10 SCTs, different electrical loads (no load, linear load, and nonlinear load), and various voltage imbalances (0%, 2.5%, 5%, 7.5%, and 10%, with 0% indicates no imbalance). Thus, the proposed model utilizes experimental vibration data to train the ANN, enabling it to identify and interpolate conditions not explicitly covered during training. Key results from this study demonstrate the model’s ability to achieve low root mean square error in both reconstructing known conditions and interpolating unknown ones. This demonstrates the model’s robustness and generalization capability, making it a valuable tool for different applications related to transformer diagnostics.