Marian Ion

Dr. Marian Ion

National Institute for Research and Development in Microtechnologies, Bucharest, Bucureşti, Romania
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Talanta
Verified
Journal Article
Closed access
MSMihaela Savin
Mihaela Savin
CMCarmen Marinela Mihailescu
Carmen Marinela Mihailescu
IMIulia Matei
Iulia Matei
DSDana Stan
Dana Stan
CMCarmen Aura Moldovan
Carmen Aura Moldovan
IBIon Baciu
Ion Baciu

1 April 2020 in Talanta
Verified
Journal Article
Closed access
CMCarmen Marinela Mihailescu
Carmen Marinela Mihailescu
DSDana Stan
Dana Stan
MSMihaela Savin
Mihaela Savin
CMCarmen Aura Moldovan
Carmen Aura Moldovan
SDSilviu Dinulescu
Silviu Dinulescu
AIAlina Catrinel Ion
Alina Catrinel Ion

16 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Marian IonMarian Ion
Marian Ion
SDSilviu Dinulescu
Silviu Dinulescu
BFBogdan Firtat
Bogdan Firtat
MSMihaela Savin
Mihaela Savin
OIOctavian Narcis Ionescu
Octavian Narcis Ionescu
CMCarmen Moldovan
Carmen Moldovan
In recent years, research into the field of materials for flexible sensors and fabrication techniques directed towards wearable devices has helped to raise awareness of the need for new sensors with healthcare applicability. Our goal was to create a wearable flexible pressure sensor that could be integrated into a clinically approved blood pressure monitoring device. The sensor is built from a microfluidic channel encapsulated between two polymer layers, one layer being covered by metal transducers and the other being a flexible membrane containing the microfluidic channel, which also acts as a sealant for the structure. The applied external pressure deforms the channel, causing changes in resistance to the microfluidic layer. Electrical characterization has been performed in 5 different configurations, using alternating current (AC) and (DC) direct current measurements. The AC measurements for the fabricated pressure sensor resulted in impedance values at tens of hundreds of kOhm. Our sensor proved to have a high sensitivity for pressure values between 0 and 150 mm Hg, being subjected to repeatable external forces. The novelty presented in our work consists in the unique technological flow for the fabrication of the flexible wearable pressure sensor. The proposed miniaturized pressure sensor will ensure flexibility, low production cost and ease of use. It is made of very sensitive microfluidic elements and biocompatible materials and can be integrated into a wearable cuffless device for continuous blood pressure monitoring.

9 January 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
OIOctavian Narcis Ionescu
Octavian Narcis Ionescu
EFEduard Franti
Eduard Franti
VCVlad Carbunaru
Vlad Carbunaru
CMCarmen Moldovan
Carmen Moldovan
SDSilviu Dinulescu
Silviu Dinulescu
Raluca D.V TeleanuRaluca D.V Teleanu
Raluca D.V Teleanu
There is great interest in the development of prosthetic limbs capable of complex activities that are wirelessly connected to the patient’s neural system. Although some progress has been achieved in this area, one of the main problems encountered is the selective acquisition of nerve impulses and the closing of the automation loop through the selective stimulation of the sensitive branches of the patient. Large-scale research and development have achieved so-called “cuff electrodes”; however, they present a big disadvantage: they are not selective. In this article, we present the progress made in the development of an implantable system of plug neural microelectrodes that relate to the biological nerve tissue and can be used for the selective acquisition of neuronal signals and for the stimulation of specific nerve fascicles. The developed plug electrodes are also advantageous due to their small thickness, as they do not trigger nerve inflammation. In addition, the results of the conducted tests on a sous scrofa subject are presented.

13 February 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
AGAlexandru Grigoroiu
Alexandru Grigoroiu
CMCarmen Marinela Mihailescu
Carmen Marinela Mihailescu
MSMihaela Savin
Mihaela Savin
CMCarmen Moldovan
Carmen Moldovan
CBCostin Brasoveanu
Costin Brasoveanu
AAAdrian Anghelescu
Adrian Anghelescu
Sensor systems for monitoring indoor air quality are vital for the precise quantification of the mechanisms which lead to the deterioration of human health, with a typical person spending an average of 20 h a day in an enclosed space. Thus, a series of layered chemoresistive sensors, obtained by the facile electrodeposition of carbon nanomaterial-enhanced PANI composites, have been tested for the selective detection of two core indoor pollutants: ammonia and nitrogen dioxide. The sensors were tested with respect to sensitivity and selectivity to the target gasses, with performance being assessed based on response linearity and repeatability at room temperature. Of the tested sensors, two have been identified as having an adequate performance on ammonia, with sensitivities of up to 96.99% and resolutions of up to 0.85 ppm being observed, while on nitrogen dioxide, despite the successful sensor having a lower sensitivity, 10.71%, it has shown high resolution, 1.25 ppm, and linearity over a large concentration domain. These high performances highlight the viability of multi-layers chemosensors based on the electrodeposition of nanomaterial-enhanced conductive polymers for the detection of pollutant gasses, with finetuning of the detection layer allowing the accurate monitoring of a wide range of gasses.

22 December 2022 in Coatings
Verified
Journal Article
Open access
PDF file
David Catalin DragomirDavid Catalin Dragomir
David Catalin Dragomir
VCVlad Carbunaru
Vlad Carbunaru
CMCarmen Moldovan
Carmen Moldovan
ILIoan Lascar
Ioan Lascar
ODOctavian Dontu
Octavian Dontu
DTDaniel MIhai Teleanu
Daniel MIhai Teleanu
The natural differences between human-made electronics and biological tissues constitute a huge challenge in materials and the manufacturing of next-generation bioelectronics. As such, we performed a series of consecutive experiments for testing the biofunctionality and biocompatibility for device implantation, by changing the exterior chemical and physical properties of electronics coating it with silicone or hydrogels. In this article, we present a comparison of the main characteristics of an electronic device coated with either silicone or hydrogel (GelMa). The coating was performed with a bioprinter for accurate silicone and hydrogel deposition around different electronic chips (Step-Down Voltage Regulator U3V15F5 from Pololu Corporation). The results demonstrate that the hydrogel coating presents an augmented biomechanical and biochemical interface and superior biocompatibility, lowers foreign body response, and considerably extends the capabilities for bioelectronic applications.