Eduard Franti

Dr. Eduard Franti


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
OIOctavian Narcis Ionescu
Octavian Narcis Ionescu
EFEduard Franti
Eduard Franti
VCVlad Carbunaru
Vlad Carbunaru
CMCarmen Moldovan
Carmen Moldovan
SDSilviu Dinulescu
Silviu Dinulescu
Raluca D.V TeleanuRaluca D.V Teleanu
Raluca D.V Teleanu
There is great interest in the development of prosthetic limbs capable of complex activities that are wirelessly connected to the patient’s neural system. Although some progress has been achieved in this area, one of the main problems encountered is the selective acquisition of nerve impulses and the closing of the automation loop through the selective stimulation of the sensitive branches of the patient. Large-scale research and development have achieved so-called “cuff electrodes”; however, they present a big disadvantage: they are not selective. In this article, we present the progress made in the development of an implantable system of plug neural microelectrodes that relate to the biological nerve tissue and can be used for the selective acquisition of neuronal signals and for the stimulation of specific nerve fascicles. The developed plug electrodes are also advantageous due to their small thickness, as they do not trigger nerve inflammation. In addition, the results of the conducted tests on a sous scrofa subject are presented.

22 December 2022 in Coatings
Verified
Journal Article
Open access
PDF file
David Catalin DragomirDavid Catalin Dragomir
David Catalin Dragomir
VCVlad Carbunaru
Vlad Carbunaru
CMCarmen Moldovan
Carmen Moldovan
ILIoan Lascar
Ioan Lascar
ODOctavian Dontu
Octavian Dontu
DTDaniel MIhai Teleanu
Daniel MIhai Teleanu
The natural differences between human-made electronics and biological tissues constitute a huge challenge in materials and the manufacturing of next-generation bioelectronics. As such, we performed a series of consecutive experiments for testing the biofunctionality and biocompatibility for device implantation, by changing the exterior chemical and physical properties of electronics coating it with silicone or hydrogels. In this article, we present a comparison of the main characteristics of an electronic device coated with either silicone or hydrogel (GelMa). The coating was performed with a bioprinter for accurate silicone and hydrogel deposition around different electronic chips (Step-Down Voltage Regulator U3V15F5 from Pololu Corporation). The results demonstrate that the hydrogel coating presents an augmented biomechanical and biochemical interface and superior biocompatibility, lowers foreign body response, and considerably extends the capabilities for bioelectronic applications.

7 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CMCarmen Moldovan
Carmen Moldovan
Marian IonMarian Ion
Marian Ion
David Catalin DragomirDavid Catalin Dragomir
David Catalin Dragomir
SDSilviu Dinulescu
Silviu Dinulescu
CMCarmen Marinela Mihailescu
Carmen Marinela Mihailescu
AOAna Maria Oproiu
Ana Maria Oproiu
In this article, we present our research achievements regarding the development of a remote sensing system for motor pulse acquisition, as a first step towards a complete neuroprosthetic arm. We present the fabrication process of an implantable electrode for nerve impulse acquisition, together with an innovative wirelessly controlled system. In our study, these were combined into an implantable device for attachment to peripheral nerves. Mechanical and biocompatibility tests were performed, as well as in vivo testing on pigs using the developed system. This testing and the experimental results are presented in a comprehensive manner, demonstrating that the system is capable of accomplishing the requirements of its designed application. Most significantly, neural electrical signals were acquired and transmitted out of the body during animal experiments, which were conducted according to ethical regulations in the field.

16 December 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
DTDaniel MIhai Teleanu
Daniel MIhai Teleanu
OIOctavian Narcis Ionescu
Octavian Narcis Ionescu
CMCarmen Moldovan
Carmen Moldovan
Marian IonMarian Ion
Marian Ion
ATAdrian Tulbure
Adrian Tulbure
Mirela Petruta SucheaMirela Petruta Suchea
Mirela Petruta Suchea
The development of implantable neural interfaces is essential for enabling bidirectional communication between the nervous system and prosthetic devices, yet their evaluation still relies primarily on in vivo models which are costly, variable, and ethically constrained. Here, we report a bio-inspired artificial nerve simulator engineered as a reproducible ex vivo platform for pre-implantation testing of plug-type electrodes. The simulator is fabricated from a conductive hydrogel composite based on reduced graphene oxide (rGO), polyaniline (PANI), agarose, sucrose, and sodium chloride, with embedded conductive channels that replicate the fascicular organization and conductivity of peripheral nerves. The resulting construct exhibits impedance values of ~2.4–2.9 kΩ between electrode needles at 1 kHz, closely matching in vivo measurements (~2 kΩ) obtained in Sus scrofa domesticus nerve tissue. Its structural and electrical fidelity enables systematic evaluation of electrode–nerve contact properties, signal transmission, and insertion behavior under controlled conditions, while reducing reliance on animal experiments. This bio-inspired simulator offers a scalable and physiologically relevant testbed that bridges materials engineering and translational neuroprosthetics, accelerating the development of next-generation implantable neural interfaces.

16 February 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
EZEleni Zingkou
Eleni Zingkou
GPGEORGIOS PAMPALAKIS
GEORGIOS PAMPALAKIS
AKAsimina Kolianou
Asimina Kolianou
NRNafsika Rossopoulou
Nafsika Rossopoulou
KSKaterina Skiada
Katerina Skiada
PGPatrick Grotemeyer
Patrick Grotemeyer
The NerveRepack project is a European initiative that aims to develop biomimetic exoskeletons/exoprostheses for amputated or paralyzed leg patients that will receive and transmit signals to enable movements and sensations for the patient. To implement the project, it is fundamental to develop implantable neuronal electrodes that will allow bidirectional signaling between the sensors placed on the exoskeletons/exoprostheses and the nervous system. In this direction, two electrodes, plug and cuff, have been designed as integral parts of the final implantable device. The electrodes should comply with strict regulations to ensure their safe implantation in patients. The purpose of this study was to support the compliance of the implant platforms of certain key components with the ISO and ASTM standards that would be required for clinical applications. We have used an indirect method to assess the biocompatibility of the developed electrodes against neuronal cells, fibroblasts, and keratinocytes. Also, we assessed hemocompatibility, i.e., the potential of implantable electrodes to induce hemolysis or complement activation. Finally, the mutagenic/genotoxic potential was tested against the internationally recommended CHO cells. Both representative plug and cuff electrode components were found non-cytotoxic, non-mutagenic, and unable to induce hemolysis. Therefore, from the point of early evaluation of in vitro material and process biocompatibility, the selected implant platforms for the electrodes could be implanted in preclinical models to delineate their potential in vivo applications as neuronal interface with the biomimetic exoskeleton/exoprostheses.

2 March 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MPMark Edward Pogarasteanu
Mark Edward Pogarasteanu
MMMarius Moga
Marius Moga
ADAdrian-Gheorghe Dobrota
Adrian-Gheorghe Dobrota
GAGeorge Avram
George Avram
MDMonica Dascalu
Monica Dascalu
COCarmen Orban
Carmen Orban
Myoelectric exoprostheses serve to aid in the everyday activities of patients with forearm or hand amputations. While electrical signals are known key factors controlling exoprosthesis, little is known about how we can improve their transmission strength from the forearm muscles as to obtain better sEMG. The purpose of this study is to evaluate the role of the forearm fascial layer in transmitting myoelectrical current. We examined the sEMG signals in three individual muscles, each from six healthy forearms (Group 1) and six amputation stumps (Group 2), along with their complete biometric characteristics. Following the tests, one patient underwent a circumferential osteoneuromuscular stump revision surgery (CONM) that also involved partial removal of fascia and subcutaneous fat in the amputation stump, with re-testing after complete healing. In group 1, we obtained a stronger sEMG signal than in Group 2. In the CONM case, after surgery, the patient’s data suggest that the removal of fascia, alongside the fibrotic and subcutaneous fat tissue, generates a stronger sEMG signal. Therefore, a reduction in the fascial layer, especially if accompanied by a reduction of the subcutaneous fat layer may prove significant for improving the strength of sEMG signals used in the control of modern exoprosthetics.