Andrija Rašeta

Prof. Dr. Andrija Rašeta

Department of Civil Engineering and Geodesy, University of Novi Sad, Faculty of Technical Sciences, Novi Sad, Serbia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Anka Starčev-ĆurčinAnka Starčev-Ćurčin
Anka Starčev-Ćurčin
ARAndrija Rašeta
Andrija Rašeta
Mirjana MaleševMirjana Malešev
Mirjana Malešev
DKDanijel Kukaras
Danijel Kukaras
Vlastimir RadonjaninVlastimir Radonjanin
Vlastimir Radonjanin
DŽDrago Žarković
Drago Žarković
The aim of the research presented in this paper is the experimental confirmation of the numerically defined shapes of the Strut-and-Tie models, designed according to the EN 1992-1-1 recommendations, and obtained from the software “ST method”. Three reinforced concrete deep beams with openings were tested. Each of them had the same dimensions and quality of the material characteristics. The specimens, constructed as simply supported beams, were loaded with two concentrated forces and were tested for bending until failure. Each specimen was reinforced with different reinforcement layout determined by variation parameter β, incorporated in the software “ST method”. For the determination of the Strut-and-Tie models, all of the reinforcement layouts were equally favored in the first specimen (β = 1.0 for 0°, 45°, and 90°), only the horizontal direction was favored in the second (β = 1.0 for 0°), while in the third specimen the one at the angle of 45° (β = 1.0 for 45°). Based on the results of experimental research, it was concluded that the behavior of loaded members was in agreement with the proposed shapes of the Strut-and-Tie models that were used for their design, and it was confirmed that the program “ST method” can be used for obtaining Strut–and-Tie models.

3 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Igor DžolevIgor Džolev
Igor Džolev
SKSofija Kekez-Baran
Sofija Kekez-Baran
ARAndrija Rašeta
Andrija Rašeta
The thermal conductivity of steel is high compared to other materials such as concrete or timber. Therefore, fire protection measures are applied to prolong the duration between the onset of fire exposure and the final loss of load-bearing function of a steel structure. The most common passive fire protection measure is the application of intumescent coating (IC), a thin film that expands at elevated temperatures and forms an insulating char layer of lower thermal conductivity. This paper focuses on structural steel beams with IPE open-section profiles protected by a water-based IC and subjected to static and standard fire loading. ANSYS 16.0 is used to simulate heat transfer, with thermal conductivity function described by standard multivariate linear regression analysis, followed by mechanical analysis considering degradation of material mechanical properties at elevated temperatures. Simulations are conducted for all IPE profile sizes, with varying initial degrees of utilisation, beam lengths, and coating thicknesses. Results indicated fire resistance times ranging from 24 to 53.5 min, demonstrating a relatively good level of fire resistance even with the minimal IC thickness. Furthermore, artificial neural networks were developed to predict the fire resistance time of steel members with IC using varying numbers of hidden neurons and subset ratios. The model achieved a predictability level of 99.9% upon evaluation.

28 April 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Dragan ManojlovićDragan Manojlović
Dragan Manojlović
ARAndrija Rašeta
Andrija Rašeta
Vladimir VukobratovićVladimir Vukobratović
Vladimir Vukobratović
AČArpad Čeh
Arpad Čeh
LKLjiljana Kozarić
Ljiljana Kozarić
Anka Starčev-ĆurčinAnka Starčev-Ćurčin
Anka Starčev-Ćurčin
Quality assessment of stiffness and load-carrying capacity of composite connections is of great importance when it comes to designing timber–concrete composite structures. The new European regulation intended explicitly for timber–concrete structures has made a significant contribution to this field, considering that until today there was no adequate design standard. Due to the proposed general expressions for determining the stiffness and load-carrying capacity of composite connections made with dowel-type fasteners, which are incapable of describing most of the commonly applied fasteners, engineering, and scientific practice remained deprived of a quality assessment of the essential mechanical properties of the connection. In order to overcome this problem, this paper proposes a numerical model of the connection suitable for determining the whole load–slip curve, allowing it to estimate the stiffness and load-carrying capacity of the connection. The model was developed by considering the non-linear behavior of timber and fasteners, which is determined through simple experimental tests. For the numerical model validation, experimental tests were carried out at the level of the applied materials and on the models of the composite connection. Through numerical simulations, analysis of obtained results, and comparison with experimental values, it can be confirmed that it is possible to simulate the pronounced non-linear behavior of the timber–concrete connection using the proposed model. The estimated values of stiffness and load-carrying capacity are in agreement with the conducted experimental testing. At the same time, the deviations are much less than the ones obtained from recommendations given by the new regulation. Additionally, apart from evaluating the value and the simulation of the complete curve, it is possible to determine local effects, such as the crushing depth in timber and concrete, the fastener’s rotation, and the participation of forces in the final capacity of the connection.

5 October 2021 in Tehnicki vjesnik - Technical Gazette
Verified
Journal Article
Closed access
PDF file
GJGoran Jeftenić
Goran Jeftenić
ARAndrija Rašeta
Andrija Rašeta
SKSrđan Kolaković
Srđan Kolaković
MPMilena Panić
Milena Panić
SKSlobodan Kolaković
Slobodan Kolaković
Vladimir MandićVladimir Mandić
Vladimir Mandić
The hydropower potential in the Republic of Serbia, as the most important renewable energy source, has been estimated at around 17000 GW·h per year, where approximately 2000 GW·h could be obtained from small hydropower plants (SHP)....

5 August 2020 in Preprints.org
Verified
Preprint
Open access
ASAnka Starčev-Ćurčin
Anka Starčev-Ćurčin
ARAndrija Rašeta
Andrija Rašeta
Mirjana MaleševMirjana Malešev
Mirjana Malešev
DKDanijel Kukaras
Danijel Kukaras
VRVlastimir Radonjanin
Vlastimir Radonjanin
DŽDrago Žarković
Drago Žarković
This paper presents the results of the experimental research and numerical analysis of three reinforced concrete deep beams with openings, designed by the Strut-and-Tie method according to the EN 1992-1-1 recommendations. All tested specimens were made in full size, with the same geometric characteristics and quality of the materials. The specimens, constructed as simply supported beams, were loaded with two concentrated forces and were tested for bending until failure. Each specimen was reinforced with different reinforcement layout determined by parameter variation within the Strut-and-Tie method. Based on the results of experimental research, it was concluded that the behavior of loaded members was in agreement with the proposed forms of the Strut-and-Tie models that were used for their design.

1 February 2016 in Tehnicki vjesnik - Technical Gazette
Verified
Journal Article
Open access
PDF file
Anka Starčev-ĆurčinAnka Starčev-Ćurčin
Anka Starčev-Ćurčin
ARAndrija Rašeta
Andrija Rašeta
ZBZoran Brujić
Zoran Brujić
The paper presents a proposal for determining the Strut-and-Tie models of reinforced concrete plane members using the discrete topology optimization, which involves the truss system for calculation of the stress-strain state of a real...