Michele Totaro

Dr. Michele Totaro

Department of Translational Research N.T.M.S., University of Pisa, Pisa, Italy

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2020 in Pathogens
Verified
Journal Article
Open access
PDF file
BTBenedetta Tuvo
Benedetta Tuvo
MTMichele Totaro
Michele Totaro
MCMaria Luisa Cristina
Maria Luisa Cristina
ASAnna Maria Spagnolo
Anna Maria Spagnolo
DCDAVID DI CAVE
DAVID DI CAVE
Beatrice CasiniBeatrice Casini
Beatrice Casini
Introduction: Dental Unit Waterlines (DUWLs) have shown to be a source of Legionella infection. We report the experience of different dental healthcare settings where a risk management plan was implemented. Materials and methods: In a Hospital Odontostomatology Clinic (HOC) and three Private Dental Clinics (PDCs) housing 13 and six dental units (DUs), respectively, an assessment checklist was applied to evaluate staff compliance with guideline recommendations. DUWLs microbial parameters were investigated before and after the application of corrective actions. Results: In the HOC a poor adherence to good practices was demonstrated, whereas protocols were carefully applied in PDCs. L. pneumophila sg 2–15 was isolated in 31% (4/13) and 33% (2/6) of DUs in HOC and PDCs, respectively, mainly from handpieces (32%, 6/19) with counts >102 colony-forming units per milliliter (CFU/L), often associated with P. aeruginosa (68%, 13/19). The shock disinfection with 3% v/v hydrogen peroxide (HP) showed a limited effect, with a recolonization period of about 4 weeks. Legionella was eradicated only after 6% v/v HP shock disinfection and filters-installation, whilst P. aeruginosa after the third shock disinfection with a solution of 4% v/v HP and biodegradable surfactants. Conclusions: Our data demonstrate the presence and persistence of microbial contamination within the DUWLs, which required strict adherence to control measures and the choice of effective disinfectants.

17 April 2017 in Pathogens
Verified
Journal Article
Open access
PDF file
Beatrice CasiniBeatrice Casini
Beatrice Casini
FAFrancesco Aquino
Francesco Aquino
MTMichele Totaro
Michele Totaro
MMMario Miccoli
Mario Miccoli
IGIrio Galli
Irio Galli
ABAngelo Baggiani
Angelo Baggiani
Objectives: To evaluate the effectiveness of hydrogen peroxide (HP) use as a disinfectant in the hospital water network for the control of Legionella spp. colonization. Methods: Following the detection of high levels of Legionella contamination in a 136-bed general hospital water network, an HP treatment of the hot water supply (25 mg/L) was adopted. During a period of 34 months, the effectiveness of HP on Legionella colonization was assessed. Legionella was isolated in accordance with ISO-11731 and identification was carried out by sequencing of the mip gene. Results: Before HP treatment, L. pneumophila sg 2–15 was isolated in all sites with a mean count of 9950 ± 8279 cfu/L. After one-month of HP treatment, we observed the disappearance of L. pneumophila 2–15, however other Legionella species previously not seen were found; Legionella pneumophila 1 was isolated in one out of four sampling sites (2000 cfu/L) and other non-pneumophila species were present in all sites (mean load 3000 ± 2887 cfu/L). Starting from September 2013, HP treatment was modified by adding food-grade polyphosphates, and in the following months, we observed a progressive reduction of the mean load of all species (p < 0.05), resulting in substantial disappearance of Legionella colonization. Conclusion: Hydrogen peroxide demonstrated good efficacy in controlling Legionella. Although in the initial phases of treatment it appeared unable to eliminate all Legionella species, by maintaining HP levels at 25 mg/L and adding food-grade polyphosphates, a progressive and complete control of colonization was obtained.

24 May 2020 in Pathogens
Verified
Journal Article
Open access
PDF file
MTMichele Totaro
Michele Totaro
Beatrice CasiniBeatrice Casini
Beatrice Casini
SPSara Profeti
Sara Profeti
BTBenedetta Tuvo
Benedetta Tuvo
GPGaetano Privitera
Gaetano Privitera
ABAngelo Baggiani
Angelo Baggiani
The emergence of multiresistant bacterial strains as agents of healthcare-related infection in hospitals has prompted a review of the control techniques, with an added emphasis on preventive measures, namely good clinical practices, antimicrobial stewardship, and appropriate environmental cleaning. The latter item is about the choice of an appropriate disinfectant as a critical role due to the difficulties often encountered in obtaining a complete eradication of environmental contaminations and reservoirs of pathogens. The present review is focused on the effectiveness of hydrogen peroxide vapor, among the new environmental disinfectants that have been adopted. The method is based on a critical review of the available literature on this topic

Beatrice CasiniBeatrice Casini
Beatrice Casini
ARAnna Righi
Anna Righi
NFNunzio De Feo
Nunzio De Feo
MTMichele Totaro
Michele Totaro
SGSerena Giorgi
Serena Giorgi
GPGaetano Pierpaolo Privitera
Gaetano Pierpaolo Privitera
Aims: High-touch surfaces cleaning and disinfection require the adoption of effective and proper executed protocols, especially during carbapenem-resistant Acinetobacter baumannii (CRAB) endemo-epidemic situations. We evaluated the effectiveness and residual disinfectant activity of disposable pre-impregnated wipes (Modified Operative Protocol, MOP) in reducing environmental bioburden versus a two-step Standard Operative Protocol (SOP) in a 12-bed Intensive Care Unit. Methods: Five high-touch surfaces were cleaned and disinfected either according to the SOP (alcohol-based cleaning and chlorine-based disinfection) or using quaternary ammonium compounds-based disposable wipes (MOP). Sampling was performed before each procedure and at 0.5, 2.5, 4.5 and 6.5 h after (560 sites). Total viable count (TVC) was evaluated according to Italian hygiene standard (<50 CFU/24 cm2). Clinical and environmental CRAB strains isolated were genotyped. Results: On non-electromedical surfaces the difference between TVC before procedure and at each of the following times was significant only for the MOP (p < 0.05, Wilcoxon test). Using the MOP, only 7.4% (10/135) of sites showed TVC >50 CFU/24 cm2 (hygiene failures) versus 18.9% (25/132) after SOP (p < 0.05, Fisher’s Exact test). On infusion pumps a higher number of hygiene failures was observed after the SOP (7/44, 15.9%) compared with the MOP (4/45, 8.9%). Genotyping highlighted a common source of infection. Conclusion: On high-touch surfaces, the use of disposable wipes by in-house auxiliary nurses may represent a more effective alternative to standard cleaning and disinfection procedure performed by outsourced cleaning services, showing effectiveness in reducing microbial contamination and residual disinfection activity up to 6.5 h.

MTMichele Totaro
Michele Totaro
PVPaola Valentini
Paola Valentini
ACAnna Laura Costa
Anna Laura Costa
LFLorenzo Frendo
Lorenzo Frendo
ACAlessia Cappello
Alessia Cappello
ABAngelo Baggiani
Angelo Baggiani
Although the European reports highlight an increase in community-acquired Legionnaires’ disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB). From all the 220 buildings Legionella spp. was researched in two hot water samples collected either at the recirculation point or on the first floor and on the last floor, while the potable water quality was analysed in three cold water samples collected at the inlet from the aqueduct network, at the exit from the autoclave, and at the most remote tap. Legionella pneumophila sg1, Legionella pneumophila sg2–16, and non-pneumophila Legionella species were detected in 26% of the hot water networks, mostly in CB and TB. In these buildings we detected correlations between the presence of Legionella and the total chlorine concentration decrease and/or the increase of the temperature. Cold water resulted free from microbiological hazards, with the exception of Serratia liquefaciens and Enterobacter cloacae isolated at the exit from two different autoclaves. We observed an increase in total microbial counts at 22 °C and 37 °C between the samples collected at the most remote taps compared to the ones collected at the inlet from the aqueduct. The study highlights a condition of potential risk for susceptible categories of population and supports the need for measures of risk assessment and control.

15 January 2019 in Pathogens
Verified
Journal Article
Open access
PDF file
MTMichele Totaro
Michele Totaro
ACAnna Laura Costa
Anna Laura Costa
Beatrice CasiniBeatrice Casini
Beatrice Casini
SPSara Profeti
Sara Profeti
AGAntonio Gallo
Antonio Gallo
ABAngelo Baggiani
Angelo Baggiani
International literature data report that the increase of infectious risk may be due to heating, ventilation and air conditioning (HVAC) systems contaminated by airborne pathogens. Moreover, the presence of complex rotating dehumidification wheels (RDWs) may complicate the cleaning and disinfection procedures of the HVAC systems. We evaluated the efficacy of a disinfection strategy applied to the RDW of two hospitals’ HVAC systems. Hospitals have four RDW systems related to the surgical areas (SA1 and SA2) and to the intensive and sub-intensive care (IC and sIC) units. Microbiological air and surface analyses were performed in HVAC systems, before and after the disinfection treatment. Hydrogen peroxide (12%) with silver ions (10 mg/L) was aerosolized in all the air sampling points, located close to the RDW device. After the air disinfection procedure, reductions of total microbial counts at 22 °C and molds were achieved in SA2 and IC HVAC systems. An Aspergillus fumigatus contamination (6 CFU/500 L), detected in one air sample collected in the IC HVAC system, was eradicated after the disinfection. The surface samples proved to be of good microbiological quality. The results suggest the need for a disinfection procedure to improve the microbiological quality of the complex HVAC systems, mostly in surgical and intensive care areas.