Matúš Ranuša

Dr. Matúš Ranuša

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DCDipankar Choudhury
Dipankar Choudhury
MRMatúš Ranuša
Matúš Ranuša
Robert FlemingRobert Fleming
Robert Fleming
MVMartin Vrbka
Martin Vrbka
IKIvan Krupka
Ivan Krupka
Min ZouMin Zou
Min Zou

1 November 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
JZJakub Zeman
Jakub Zeman
MRMatúš Ranuša
Matúš Ranuša
MVMartin Vrbka
Martin Vrbka
Jiri GalloJiri Gallo
Jiri Gallo
IKIvan Krupka
Ivan Krupka
MHMartin Hartl
Martin Hartl

19 December 2024 in Tribology Letters
Verified
Journal Article
Open access
PDF file
MRMatúš Ranuša
Matúš Ranuša
LOLukáš Odehnal
Lukáš Odehnal
OKOndřej Kučera
Ondřej Kučera
DNDavid Nečas
David Nečas
MHMartin Hartl
Martin Hartl
MVMartin Vrbka
Martin Vrbka
The number of endoprosthetic implants for both large and small joints is increasing at a steady rate, thereby creating a growing demand for durable products that closely replicate the functionality of human joints. Notwithstanding the aforementioned advancements, challenges pertaining to implant fixation and tribological surfaces persist. The advent of progressive technologies, such as three-dimensional printing, offers a promising avenue for addressing these challenges in implant design and surface engineering. The Ti6Al4V and CoCrMo alloys, renowned for their biocompatibility and osseointegration properties, represent promising printable materials, although they are susceptible to wear on articulating surfaces. In order to mitigate the effects of abrasion, it is essential to implement surface treatments to facilitate the formation of a robust lubricating film. This research investigates the potential of texturing and electrochemical polishing to enhance protein aggregation in the contact area. The study employs a reciprocating simulator and colorimetric interferometry to observe the contact area and measure the coefficient of friction (CoF) of modified surfaces. The findings demonstrate that textured surfaces and the combination of electrochemical polishing result in an increase in the thickness of the protein lubrication film, which may potentially reduce wear. These outcomes suggest the potential for the utilization of Ti6Al4V alloy implants with fewer elements manufactured by additive technology. Graphical

23 May 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MRMatúš Ranuša
Matúš Ranuša
PČPavel Čípek
Pavel Čípek
MVMartin Vrbka
Martin Vrbka
DPDavid Paloušek
David Paloušek
IKIvan Křupka
Ivan Křupka
MHMartin Hartl
Martin Hartl

3 April 2021 in Lubricants
Verified
Journal Article
Open access
PDF file
MRMatúš Ranuša
Matúš Ranuša
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer
SFSpencer Fullam
Spencer Fullam
MVMartin Vrbka
Martin Vrbka
IKIvan Krupka
Ivan Krupka
Total knee arthroplasty is on the rise worldwide. Despite its success, revision surgeries are also increasing. According to the American Joint Replacement Registry 2020, 3.3% of revision surgeries are due to wear, and 24.2% are due to mechanical loosening. The combination of shear stresses and wear particles occurring at the bone/implant interface can lead to local osteolysis. Although the shear stresses are partially driven by joint friction, relatively little is known about the evolution of the coefficient of friction (CoF) during a gait cycle in total knee replacement. Here we describe the CoF during a gait cycle and investigate its association with kinematics (slide–roll-ratio), applied load, and relative velocity. The artificial knee was simulated by cobalt–chromium condyle on a flat ultra-high-molecular-weight polyethylene (UHMWPE) tibial plateau, lubricated by either water or proteinaceous solution. We found that the CoF is not a constant but fluctuates between the values close to 0 and 0.15. Cross-correlation suggested that this is primarily an effect of the slide–roll ratio and the contact pressure. There was no difference in the CoF between water and proteinaceous solution. Knowledge about the CoF behavior during a gait cycle will help to increase the accuracy of future computational models of total knee replacement.

25 August 2016 in Tribology Transactions
Verified
Journal Article
Closed access
MRMatúš Ranuša
Matúš Ranuša
Jiri GalloJiri Gallo
Jiri Gallo
MVMartin Vrbka
Martin Vrbka
MHMartin Hobza
Martin Hobza
DPDavid Palousek
David Palousek
MHMartin Hartl
Martin Hartl
Wear analysis of total hip replacements (THRs) is considered one of the most relevant research areas helping to improve the longevity and overall design of THRs. The coordinate machine method (CMM) and Fourier profilometry are the most common methods for measuring THR wear. This article presents optical scanner digitalization as a new method for measuring the wear of polyethylene (PE) acetabular cups. The aim of this article is to explore the potential of this method for the PE wear measurements. Optical scans for the purposes of this study were produced using an ATOS Triple Scan 3D optical scanner. The optical scanner is efficient and it can measure a large number of points for polygonization and for further development of the preworn models. In this study, the scanner first generated point clouds on a sample of 13 retrieved ultra-high-molecular-weight polyethylene (UHMWPE) acetabular cups. Next, volumetric models of the cups were created by polygonizing the point clouds. Reverse engineering was used to develop models of the original acetabular cups using the geometry of the unworn parts of the retrieved cups. A comparison of the two models then showed the total volume of the PE debris. The optical scanning method was validated against the gravimetric method using three new acetabular cups that were worn out on a hip pendulum simulator. Validation shows that the optical scanning method is a valid method for wear analysis of the retrieved UHMWPE acetabular cups.