Linfeng Xu

Linfeng Xu


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2019 in Nature Methods
Verified
Journal Article
Closed access
PDF file
BYBin Yang
Bin Yang
XCXingye Chen
Xingye Chen
YWYina Wang
Yina Wang
SFSiyu Feng
Siyu Feng
VPVeronica Pessino
Veronica Pessino
BHBo Huang
Bo Huang

13 August 2015 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
LXLinfeng Xu
Linfeng Xu
HLHun Lee
Hun Lee
DJDeekshitha Jetta
Deekshitha Jetta
Kwang W. OhKwang W. Oh
Kwang W. Oh
This article provides a comprehensive overview of the physics of the gas solubility and permeability of PDMS, a systematic review of different types of vacuum-driven power-free microfluidics, design guidelines, existing applications, and the outlook.

1 May 2020 in Biomicrofluidics
Verified
Journal Article
Open access
PDF file
LXLinfeng Xu
Linfeng Xu
AWAnyang Wang
Anyang Wang
XLXiangpeng Li
Xiangpeng Li
Kwang W. OhKwang W. Oh
Kwang W. Oh
Suitable micropumping methods for flow control represent a major technical hurdle in the development of microfluidic systems for point-of-care testing (POCT). Passive micropumping for point-of-care microfluidic systems provides a promising solution to such challenges, in particular, passive micropumping based on capillary force and air transfer based on the air solubility and air permeability of specific materials. There have been numerous developments and applications of micropumping techniques that are relevant to the use in POCT. Compared with active pumping methods such as syringe pumps or pressure pumps, where the flow rate can be well-tuned independent of the design of the microfluidic devices or the property of the liquids, most passive micropumping methods still suffer flow-control problems. For example, the flow rate may be set once the device has been made, and the properties of liquids may affect the flow rate. However, the advantages of passive micropumping, which include simplicity, ease of use, and low cost, make it the best choice for POCT. Here, we present a systematic review of different types of passive micropumping that are suitable for POCT, alongside existing applications based on passive micropumping. Future trends in passive micropumping are also discussed.

24 January 2022 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
JMJustin L. Madrigal
Justin L. Madrigal
NSNathan G. Schoepp
Nathan G. Schoepp
LXLinfeng Xu
Linfeng Xu
CPCodian S. Powell
Codian S. Powell
CDCyrille L. Delley
Cyrille L. Delley
AAAdam Abate
Adam Abate
Significance: The study of specific cell–cell interactions at scale would be a significant advancement in single-cell biology with clear utility in immuno-oncology. Our development of Droplet Assembly provides a tool for such studies by extending the benefits of single-cell droplet microfluidics to high-order cell analyses. This technology allows for the construction, sorting, and downstream processing of cell–cell interactions and is compatible with single-cell genomic readouts.

12 September 2014 in Sensors
Verified
Journal Article
Open access
PDF file
HLHun Lee
Hun Lee
LXLinfeng Xu
Linfeng Xu
DKDomin Koh
Domin Koh
NNNikhila Nyayapathi
Nikhila Nyayapathi
Kwang W. OhKwang W. Oh
Kwang W. Oh
In this paper, we review recent advances in on-chip sensors integrated with microfluidics for biological applications. Since the 1990s, much research has concentrated on developing a sensing system using optical phenomena such as surface plasmon resonance (SPR) and surface-enhanced Raman scattering (SERS) to improve the sensitivity of the device. The sensing performance can be significantly enhanced with the use of microfluidic chips to provide effective liquid manipulation and greater flexibility. We describe an optical image sensor with a simpler platform for better performance over a larger field of view (FOV) and greater depth of field (DOF). As a new trend, we review consumer electronics such as smart phones, tablets, Google glasses, etc. which are being incorporated in point-of-care (POC) testing systems. In addition, we discuss in detail the current optical sensing system integrated with a microfluidic chip.

1 March 2012 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
KLKangsun Lee
Kangsun Lee
CKChoong Kim
Choong Kim
JYJae Young Yang
Jae Young Yang
HLHun Lee
Hun Lee
BAByungwook Ahn
Byungwook Ahn
Kwang W. OhKwang W. Oh
Kwang W. Oh
We propose a simple method for forming massive and uniform three-dimensional (3-D) cell spheroids in a multi-level structured microfluidic device by gravitational force. The concept of orienting the device vertically has allowed spheroid formation, long-term perfusion, and retrieval of the cultured spheroids by user-friendly standard pipetting. We have successfully formed, perfused, and retrieved uniform, size-controllable, well-conditioned spheroids of human embryonic kidney 293 cells (HEK 293) in the gravity-oriented microfluidic device. We expect the proposed method will be a useful tool to study in-vitro 3-D cell models for the proliferation, differentiation, and metabolism of embryoid bodies or tumours.