Hee Won Seo

Mr. Hee Won Seo

Daegu Gyeongbuk Institute of Science and Technology (DGIST)
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YLYuhyun Lee
Yuhyun Lee
HSHee Won Seo
Hee Won Seo
KLKyeong Jae Lee
Kyeong Jae Lee
JJJae-Won Jang
Jae-Won Jang
SKSohee Kim
Sohee Kim
Along with the increasing popularity of larval zebrafish as an experimental animal in the fields of drug screening, neuroscience, genetics, and developmental biology, the need for tools to deal with multiple larvae has emerged. Microfluidic channels have been employed to handle multiple larvae simultaneously, even for sensing electroencephalogram (EEG). In this study, we developed a microfluidic chip capable of uniform and continuous drug infusion across all microfluidic channels during EEG recording. Owing to the modular design of the microfluidic channels, the number of animals under investigation can be easily increased. Using the optimized design of the microfluidic chip, liquids could be exchanged uniformly across all channels without physically affecting the larvae contained in the channels, which assured a stable environment maintained all the time during EEG recording, by eliminating environmental artifacts and leaving only biological effects to be seen. To demonstrate the usefulness of the developed system in drug screening, we continuously measured EEG from four larvae without and with pentylenetetrazole application, up to 60 min. In addition, we recorded EEG from valproic acid (VPA)-treated zebrafish and demonstrated the suppression of seizure by VPA. The developed microfluidic system could contribute to the mass screening of EEG for drug development to treat neurological disorders such as epilepsy in a short time, owing to its handy size, cheap fabrication cost, and the guaranteed uniform drug infusion across all channels with no environmentally induced artifacts.

21 August 2019 in Journal of Neural Engineering
Verified
Journal Article
Closed access
HSHee Won Seo
Hee Won Seo
NKNamju Kim
Namju Kim
JAJungryul Ahn
Jungryul Ahn
SCSeongkwang Cha
Seongkwang Cha
YGYong Sook Goo
Yong Sook Goo
SKSohee Kim
Sohee Kim
Objective . Various retinal prostheses have been developed to restore the vision for blind patients, and some of them are already in clinical use. In this paper, we present a three-dimensional (3D) microelectrode array for a subretinal device that can effectively stimulate retinal cells. Approach . To investigate the effect of electrode designs on the electric field distribution, we simulated various electrode shapes and sizes using finite element analysis. Based on the simulation results, the 3D microelectrode array was fabricated and evaluated in in vitro condition. Main results . Through the simulation, we verified that an electrode design of square frustum was effective to stimulate with high contrast. Also, the 3D flexible and transparent microelectrode array based on silicon and polydimethylsiloxane was fabricated using micro-electro-mechanical system technologies. In in vitro experiments, the subretinally positioned 3D microelectrodes properly evoked spikes in retinal ganglion cells. The mean threshold current was 7.4 µ A and the threshold charge density was 33.64 µ C·cm −2 per phase. Significance . The results demonstrate the feasibility of the fabricated 3D microelectrodes as the subretinal prosthesis. The developed microelectrode array would be integrated with the stimulation circuitry and implanted in animals for further in vivo experiments.

1 July 2015 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
HSHee Won Seo
Hee Won Seo
JCJeong Byung Chae
Jeong Byung Chae
SHSung Jin Hong
Sung Jin Hong
KRKyehan Rhee
Kyehan Rhee
JCJong-Hyeon Chang
Jong-Hyeon Chang
SCSang Kug Chung
Sang Kug Chung

29 April 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
HSHee Won Seo
Hee Won Seo
NKNamju Kim
Namju Kim
SKSohee Kim
Sohee Kim
This study presents the fabrication of three-dimensional (3D) microelectrodes for subretinal stimulation, to accommodate adjacent return electrodes surrounding a stimulating electrode. For retinal prosthetic devices, the arrangement of return electrodes, the electrode size and spacing should be considered together, to reduce the undesired dissipation of electric currents. Here, we applied the hexagonal arrangement to the microelectrode array for the localized activation of retinal cells and better visual acuity. To provide stimuli more efficiently to non-spiking neurons, a 3D structure was created through a customized pressing process, utilizing the elastic property of the materials used in the fabrication processes. The diameter and pitch of the Pt-coated electrodes were 150 μm and 350 μm, respectively, and the height of the protruded electrodes was around 20 μm. The array consisted of 98 hexagonally arranged electrodes, supported by a flexible and transparent polydimethylsiloxane (PDMS) base, with a thickness of 140 μm. Also, the array was coated with 2 μm-thick parylene-C, except the active electrode sites, for more focused stimulation. Finally, the electrochemical properties of the fabricated microelectrodes were characterized, resulting in the mean impedance of 384.87 kΩ at 1 kHz and the charge storage capacity (CSC) of 2.83 mC·cm−2. The fabricated microelectrodes are to be combined with an integrated circuit (IC) for additional in vitro and in vivo experiments.

17 December 2015 in Langmuir
Verified
Journal Article
Closed access
SHSung Jin Hong
Sung Jin Hong
JHJiwoo Hong
Jiwoo Hong
HSHee Won Seo
Hee Won Seo
SLSang Joon Lee
Sang Joon Lee
SCSang Kug Chung
Sang Kug Chung

19 November 2021 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
JJJae-Won Jang
Jae-Won Jang
YKYoo Na Kang
Yoo Na Kang
HSHee Won Seo
Hee Won Seo
BKBoil Kim
Boil Kim
HCHan Kyoung Choe
Han Kyoung Choe
SKSohee Kim
Sohee Kim
Objective. Neural interfaces are an essential tool to enable the human body to directly communicate with machines such as computers or prosthetic robotic arms. Since invasive electrodes can be located closer to target neurons, they have advantages such as precision in stimulation and high signal-to-noise ratio (SNR) in recording, while they often exhibit unstable performance in long-term in-vivo implantation because of the tissue damage caused by the electrodes insertion. In the present study, we investigated the electrical functionality of flexible penetrating microelectrode arrays (FPMAs) up to 3 months in in-vivo conditions. Approach. The in-vivo experiment was performed by implanting FPMAs in five rats. The in-vivo impedance as well as the action potential (AP) amplitude and SNR were analyzed over weeks. Additionally, APs were tracked over time to investigate the possibility of single neuron recording. Main results. It was observed that the FPMAs exhibited dramatic increases in impedance for the first 4 weeks after implantation, accompanied by decreases in AP amplitude. However, the increase/decrease in AP amplitude was always accompanied by the increase/decrease in background noise, resulting in quite consistently maintained SNRs. After 4 weeks of implantation, we observed two distinctive issues regarding long-term implantation, each caused by chronic tissue responses or by the delamination of insulation layer. The results demonstrate that the FPMAs successfully recorded neuronal signals up to 12 weeks, with very stably maintained SNRs, reduced by only 16.1% on average compared to the first recordings, although biological tissue reactions or physical degradation of the FPMA were present. Significance. The fabricated FPMAs successfully recorded intracortical signals for 3 months. The SNR was maintained up to 3 months and the chronic function of FPMA was comparable with other silicon based implantable electrodes.