Yoo Na Kang

Yoo Na Kang

Auto-generated profile, based on publicly available information

Yoo Na Kang

Department of Medical Device Korea Institute of Machinery and Materials Daegu 42994 Republic of Korea

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2020 in Advanced Materials Interfaces
Verified
Journal Article
Closed access
PDF file
KLKyeong Yeon Lee
Kyeong Yeon Lee
HMHyunmin Moon
Hyunmin Moon
BKBoil Kim
Boil Kim
YKYoo Na Kang
Yoo Na Kang
JJJae‐Won Jang
Jae‐Won Jang
SKSohee Kim
Sohee Kim

21 May 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
YKYoo Na Kang
Yoo Na Kang
NCNamsun Chou
Namsun Chou
JJJae-Won Jang
Jae-Won Jang
DBDonghak Byun
Donghak Byun
HKHosung Kang
Hosung Kang
SKSohee Kim
Sohee Kim
For implantable devices, Parylene C (hereafter referred to as “Parylene”) has shown promising properties such as flexibility, biocompatibility, biostability, and good barrier properties. Parylene-based flexible interconnection cable (FIC) was previously developed to connect a flexible penetrating microelectrode array (FPMA) with a recording system. However, Parylene-based FIC was difficult to handle and prone to damage during the implantation surgery because of its low mechanical strength. To improve the mechanical properties of the FIC, we suggest a mechanically enhanced flexible interconnection cable (enhanced FIC) obtained using a combination of Parylene and polyimide. To investigate the long-term stability of the enhanced FIC, Parylene-only FIC and enhanced FIC were tested and their mechanical properties were compared under an accelerated aging condition. During the course of six months of soaking, the maximum strength of the enhanced FIC remained twice as high as that of the Parylene-only FIC throughout the experiment, although the mechanical strength of both FICs decreased over time. To show the capability of the enhanced FIC in the context of nerve signal recording as a part of a neural interfacing device, it was assembled together with the FPMA and custom-made wireless recording electronics. We demonstrated the feasibility of the enhanced FIC in an in vivo application by recording acute nerve signals from canine sciatic nerves.

19 November 2021 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
JJJae-Won Jang
Jae-Won Jang
YKYoo Na Kang
Yoo Na Kang
HSHee Won Seo
Hee Won Seo
BKBoil Kim
Boil Kim
HCHan Kyoung Choe
Han Kyoung Choe
SKSohee Kim
Sohee Kim
Objective. Neural interfaces are an essential tool to enable the human body to directly communicate with machines such as computers or prosthetic robotic arms. Since invasive electrodes can be located closer to target neurons, they have advantages such as precision in stimulation and high signal-to-noise ratio (SNR) in recording, while they often exhibit unstable performance in long-term in-vivo implantation because of the tissue damage caused by the electrodes insertion. In the present study, we investigated the electrical functionality of flexible penetrating microelectrode arrays (FPMAs) up to 3 months in in-vivo conditions. Approach. The in-vivo experiment was performed by implanting FPMAs in five rats. The in-vivo impedance as well as the action potential (AP) amplitude and SNR were analyzed over weeks. Additionally, APs were tracked over time to investigate the possibility of single neuron recording. Main results. It was observed that the FPMAs exhibited dramatic increases in impedance for the first 4 weeks after implantation, accompanied by decreases in AP amplitude. However, the increase/decrease in AP amplitude was always accompanied by the increase/decrease in background noise, resulting in quite consistently maintained SNRs. After 4 weeks of implantation, we observed two distinctive issues regarding long-term implantation, each caused by chronic tissue responses or by the delamination of insulation layer. The results demonstrate that the FPMAs successfully recorded neuronal signals up to 12 weeks, with very stably maintained SNRs, reduced by only 16.1% on average compared to the first recordings, although biological tissue reactions or physical degradation of the FPMA were present. Significance. The fabricated FPMAs successfully recorded intracortical signals for 3 months. The SNR was maintained up to 3 months and the chronic function of FPMA was comparable with other silicon based implantable electrodes.

24 March 2024 in Advanced Materials Technologies
Verified
Journal Article
Open access
NKNamju Kim
Namju Kim
YHYeji Hong
Yeji Hong
SCSeongkwang Cha
Seongkwang Cha
YKYoo Na Kang
Yoo Na Kang
HSHee Won Seo
Hee Won Seo
SKSohee Kim
Sohee Kim
Components in neural implants, such as the electrode array and stimulator circuit, are often fabricated discretely. This modular fabrication scheme offers flexibility during development but poses difficulties during assembly, as components must be compactly integrated for implantation. It is particularly difficult in cases where the electrode array is required to have a high number of channels, such as in retinal prostheses. This paper presents the development of a parylene C‐based, double‐sided microelectrode array with 294 hemispheric electrodes for subretinal stimulation. The bonding pads on the bottom side of the double‐sided array are connected with electrodes through vias, eliminating the interconnection lines. The array can be integrated with a stimulator circuit through pad‐to‐pad bonding, resulting in a compact implant. The hemispheric electrodes are fabricated using thermally reflowed photoresist infillings, through which the height and width of the hemispheres can be easily controlled. The long‐term stability and biocompatibility of the materials and methods used to fabricate and package the electrodes are demonstrated in in vitro and in vivo environments over months. Finally, subretinal stimulation by the developed electrodes is successfully demonstrated using in vitro retinal patches from mice and monkeys.

1 July 2017
Verified
Conference Paper
Closed access
NCNamsun Chou
Namsun Chou
YKYooNa Kang
YooNa Kang
HKHo-Seong Kang
Ho-Seong Kang
JYJeong-Dae Yun
Jeong-Dae Yun
WCWonju Chun
Wonju Chun
SKSohee Kim
Sohee Kim
This paper describes an intrafascicular neural interface for peripheral nerve implantation. The flexible penetrating microelectrode array with varying lengths (vl-FPMA), interconnection cable, wireless recording and stimulator modules were designed and fabricated to detect neural signals from the peripheral nerves or to stimulate them. The vl-FPMA consisted of silicon needles and polydimethylsiloxane (PDMS) platform supporting the needles. The length of electrode needles varied from 600 to 1000 μm. The interconnection cable was fabricated as parylene-metal-parylene sandwiched structure. The wireless recording/stimulation modules were also developed and connected with the electrodes. The integrated system was implanted in the sciatic nerve of beagles and the recording capability of the integrated system was demonstrated successfully.

2 September 2015 in The Analyst
Verified
Journal Article
Closed access
PDF file
BKBon Ung Koo
Bon Ung Koo
YKYooNa Kang
YooNa Kang
SMSangJun Moon
SangJun Moon
Won Gu LeeWon Gu Lee
Won Gu Lee
A specially designed disc to reduce cell damage by controlling total fluorescence exposure time without deterioration of image resolution which is simple, cost-effective, and easily integrated into the optical pathway through a conventional fluorescence microscope.