21 August 2019 in Journal of Neural Engineering
Objective . Various retinal prostheses have been developed to restore the vision for blind patients, and some of them are already in clinical use. In this paper, we present a three-dimensional (3D) microelectrode array for a subretinal device that can effectively stimulate retinal cells. Approach . To investigate the effect of electrode designs on the electric field distribution, we simulated various electrode shapes and sizes using finite element analysis. Based on the simulation results, the 3D microelectrode array was fabricated and evaluated in in vitro condition. Main results . Through the simulation, we verified that an electrode design of square frustum was effective to stimulate with high contrast. Also, the 3D flexible and transparent microelectrode array based on silicon and polydimethylsiloxane was fabricated using micro-electro-mechanical system technologies. In in vitro experiments, the subretinally positioned 3D microelectrodes properly evoked spikes in retinal ganglion cells. The mean threshold current was 7.4 µ A and the threshold charge density was 33.64 µ C·cm −2 per phase. Significance . The results demonstrate the feasibility of the fabricated 3D microelectrodes as the subretinal prosthesis. The developed microelectrode array would be integrated with the stimulation circuitry and implanted in animals for further in vivo experiments.
24 March 2024 in Advanced Materials Technologies
Components in neural implants, such as the electrode array and stimulator circuit, are often fabricated discretely. This modular fabrication scheme offers flexibility during development but poses difficulties during assembly, as components must be compactly integrated for implantation. It is particularly difficult in cases where the electrode array is required to have a high number of channels, such as in retinal prostheses. This paper presents the development of a parylene C‐based, double‐sided microelectrode array with 294 hemispheric electrodes for subretinal stimulation. The bonding pads on the bottom side of the double‐sided array are connected with electrodes through vias, eliminating the interconnection lines. The array can be integrated with a stimulator circuit through pad‐to‐pad bonding, resulting in a compact implant. The hemispheric electrodes are fabricated using thermally reflowed photoresist infillings, through which the height and width of the hemispheres can be easily controlled. The long‐term stability and biocompatibility of the materials and methods used to fabricate and package the electrodes are demonstrated in in vitro and in vivo environments over months. Finally, subretinal stimulation by the developed electrodes is successfully demonstrated using in vitro retinal patches from mice and monkeys.
28 October 2020 in Scientific Reports
We sought to describe the surgical techniques required in the ab-interno method to implant subretinal prostheses in mini-pigs and suggest tips to facilitate optimal outcomes. During vitrectomy, the use of valved trocar cannulas was essential to stabilize the detached retina and implanted chip. As a first step in retinal detachment, a 23-gauge cannula with very small amount of viscoelastic material was used to establish the retinal hole and promote retinal detachment. Then, balanced salt solution was applied to increase the retinal detachment and diathermy was used to make opening for subretinal prosthesis. For easy positioning of the subretinal prosthesis, a curved laser probe was adopted when handling the subretinal prosthesis under the retina. After surgery, the sclerotomy sites were tightly sutured to prevent silicone oil leakage. Without special equipment, such as a 41-gauge tip, retinal detachment could be induced easily, while the prosthesis was also successfully inserted and manipulated under the retina without an iatrogenic retinal tear. Two weeks after the operation, the oil fully occupied the intraocular volume without leakage. The subretinal prosthesis remained stable without complication. Understanding the principle of the ab-interno method and considering several tips for improving surgical access may help to enhance surgical success rates of subretinal prostheses implantation.