The cardioprotective properties of extracellular vesicles (EVs) derived from mesenchymal stromal cells (MSCs) are currently being investigated in preclinical studies. Although microRNAs (miRNAs) encapsulated in EVs have been identified as one component responsible for the cardioprotective effect of MSCs, their potential off-target effects have not been sufficiently characterized. In the present study, we aimed to investigate the miRNA profile of EVs isolated from MSCs that were derived from cord blood (CB) and adipose tissue (AT). The identified miRNAs were then compared to known targets from the literature to discover possible adverse effects prior to clinical use. Our data show that while many cardioprotective miRNAs such as miR-22-3p, miR-26a-5p, miR-29c-3p, and miR-125b-5p were present in CB- and AT-MSC-derived EVs, a large number of known oncogenic and tumor suppressor miRNAs such as miR-16-5p, miR-23a-3p, and miR-191-5p were also detected. These findings highlight the importance of quality assessment for therapeutically applied EV preparations.
Small extracellular vesicles (sEVs) are non-replicating, membrane-derived nanoparticles secreted by cells into the extracellular space.1,2 They carry bioactive molecules that can modulate recipient cell functions. When derived from human cardiac progenitor cells (CPCs) or cardiosphere-derived cells (CDCs), sEVs are hypoimmunogenic and cardioprotective and exhibit pro-angiogenic capacity, making them attractive candidates for the treatment of acute myocardial infarction (AMI). We and others have shown that sEVs secreted by human CPCs or CDCs reduce infarct size and improve cardiac function in AMI models3–6; however, benefits have only been demonstrated after their intramyocardial (IM) injection in open-chest AMI models. Since most AMI patients undergo emergency percutaneous coronary intervention (PCI), clinical translation of sEV-based therapies will require percutaneous delivery modalities. While intracoronary (IC) delivery of sEVs during PCI would be suitable for AMI patients, a previous study in porcine AMI showed a lack of efficacy.5 In contrast, percutaneous, catheter-based IM delivery of CDC-sEVs using the NOGA cardiac navigation system showed promise in a porcine model of convalescent myocardial infarction.5
The microenvironment of mesenchymal stem cells (MSCs) is responsible for the modulation in MSC commitment. Nanocomposites with an inorganic and an organic component have been investigated, and osteogenesis of MSCs has been attributed to inorganic phases such as calcium phosphate under several conditions. Here, electrospun meshes and two-dimensional films of poly(lactic-co-glycolic acid) (PLGA) or nanocomposites of PLGA and amorphous calcium phosphate nanoparticles (PLGA/aCaP) seeded with human adipose-derived stem cells (ASCs) were analyzed for the expression of selected marker genes. In a two-week in vitro experiment, osteogenic commitment was not found to be favored on PLGA/aCaP compared to pure PLGA. Analysis of the medium revealed a significant reduction of the Ca2+ concentration when incubated with PLGA/aCaP, caused by chemical precipitation of hydroxyapatite (HAp) on aCaP seeds of PLGA/aCaP. Upon offering a constant Ca2+ concentration, however, the previously observed anti-osteogenic effect was reversed: alkaline phosphatase, an early osteogenic marker gene, was upregulated on PLGA/aCaP compared to pristine PLGA. Hence, in addition to the cell–material interaction, the material–medium interaction was also important for the stem cell commitment here, affecting the cell–medium interaction. Complex in vitro models should therefore consider all factors, as coupled impacts might emerge.
Specific microenvironments can trigger stem cell tenogenic differentiation, such as specific substrates or dynamic cell cultivation. Electrospun meshes composed by core–shell fibers (random or aligned; PDMS core; piezoelectric PVDFhfp shell) were fabricated by coaxial electrospinning. Elastic modulus and residual strain were assessed. Human ASCs were seeded on such scaffolds either under static conditions for 1 week or with subsequent 10% dynamic stretching for 10,800 cycles (1 Hz, 3 h), assessing load elongation curves in a Bose® bioreactor system. Gene expression for tenogenic expression, extracellular matrix, remodeling, pro-fibrotic and inflammatory marker genes were assessed (PCR). For cell-seeded meshes, the E modulus increased from 14 ± 3.8 MPa to 31 ± 17 MPa within 3 h, which was not observed for cell-free meshes. Random fibers resulted in higher tenogenic commitment than aligned fibers. Dynamic cultivation significantly enhanced pro-inflammatory markers. Compared to ASCs in culture flasks, ASCs on random meshes under static cultivation showed a significant upregulation of Mohawk, Tenascin-C and Tenomodulin. The tenogenic commitment expressed by human ASCs in contact with random PVDFhfp/PDMS paves the way for using this novel highly elastic material as an implant to be wrapped around a lacerated tendon, envisioned as a functional anti-adhesion membrane.
Recently, a tumor model based on the chorioallantoic membrane (CAM) was characterized structurally with Magnetic Resonance Imaging (MRI). Yet, capability of MRI to assess vascular functional reserve and potential of oxygenation-sensitive MRI remain largely unexplored in this model. For this purpose, we compared MC-38 colon and A549 lung adenocarcinoma cell grafts grown on the CAM, using quantitative T1 and T2* MRI readouts as imaging markers. These are associated with vascular functionality and oxygenation status when compared between periods of air and carbogen exposure. Our data show that in A549 lung adenocarcinoma cell grafts T2* values increased significantly upon carbogen exposure (p < 0.004, Wilcoxon test; no change in T1), while MC-38 grafts displayed no changes in T1 and T2*), indicating that the grafts differ in their vascular response. Heterogeneity with regard to T1 and T2* distribution within the grafts was noted. MC-38 grafts displayed larger T1 and T2* in the graft centre, while in A549 they were distributed more towards the graft surface. Finally, qualitative assessment of gadolinium-enhancement suggests that A549 grafts display more prominent enhancement compared to MC-38 grafts. Furthermore, MC-38 grafts had 65% larger volumes than A549 grafts. Histology revealed distinct underlying phenotypes of the two tumor grafts, pertaining to the proliferative status (Ki-67) and cellularity (H&E). In sum, a functional gas challenge with carbogen is feasible through gas exchange on the CAM, and it affects MRI signals associated with vascular reactivity and oxygenation status of the tumor graft planted on the CAM. Different grafts based on A549 lung adenocarcinoma and MC-38 colon carcinoma cell lines, respectively, display distinct phenotypes that can be distinguished and characterized non-invasively in ovo using MRI in the living chicken embryo.
Tendon injuries can result in two major drawbacks. Adhesions to the surrounding tissue may limit the range of motion, while fibrovascular scar formation can lead to poor biomechanical outcomes. Prosthetic devices may help to mitigate those problems. Emulsion electrospinning was used to develop a novel three-layer tube based on the polymer DegraPol (DP), with incorporated insulin-like growth factor-1 (IGF-1) in the middle layer. Scanning electron microscopy was utilized to assess the fiber diameter in IGF-1 containing pure DP meshes. Further characterization was performed with Fourier Transformed Infrared Spectroscopy, Differential Scanning Calorimetry, and water contact angle, as well as through the assessment of mechanical properties and release kinetics from ELISA, and the bioactivity of IGF-1 by qPCR of collagen I, ki67, and tenomodulin in rabbit Achilles tenocytes. The IGF-1-containing tubes exhibited a sustained release of the growth factor up to 4 days and showed bioactivity by significantly upregulated ki67 and tenomodulin gene expression. Moreover, they proved to be mechanically superior to pure DP tubes (significantly higher fracture strain, failure stress, and elastic modulus). The novel three-layer tubes intended to be applied over conventionally sutured tendons after a rupture may help accelerate the healing process. The release of IGF-1 stimulates proliferation and matrix synthesis of cells at the repair site. In addition, adhesion formation to surrounding tissue can be reduced due to the physical barrier.