Pulse Shape Discrimination (PSD) techniques, particularly the widely employed charge integration ratio method (Q-ratio), have proven effective in discriminating fast neutrons from gamma rays in organic scintillation detectors. However, the effectiveness of Q-ratio diminishes in the low-energy region (below 150 keVee) due to overlapping signal, leading to a suboptimal Figure of Merit (FOM). In this study, we use machine learning (ML) technique, particularly the one-dimensional Convolutional Neural Network (1D-CNN), to enhance the neutron/gamma discrimination and compares the results with the traditional charge integration ratio in the low-energy region. Our investigation focuses on the EJ-276 plastic scintillator, a commercial product of ELJEN technology known for its good separation of gamma and fast neutron signals based on timing characteristics. Experimental data were acquired using 252 Cf and 60 Co radioisotope sources. A comprehensive comparative analysis between the traditional Q-ratio method and ML algorithms is conducted for the low energy region. Our main objective is to evaluate and enhance neutron/gamma discrimination capabilities of plastic scintillators in this low-energy region.
27 September 2021 in Asia-Pacific Journal of Atmospheric Sciences
This study presents advancements in coincidence electronics and a Pulse Height Analyzer (PHA) utilizing commercial FPGA-based (Field-Programmable Gate Array) hardware for radiation scintillation detectors. The hardware, based on a cost-effective NI myRIO device, integrates an FPGA, ARM Cortex-A9 processor, analog input (AI), digital input and output (DIO), and USB/wireless connectivity with a host computer. LabVIEW codes developed on the LabVIEW™ platform are implemented in the NI myRIO hardware for seamless integration and interfacing with a computer. The performance of the FPGA-based coincidence electronics is assessed through an experimental setup measuring the gamma-gamma angular distribution of a 22 Na radioisotope source. Similarly, the FPGA-based PHA is tested with a CsI(Tl) detector, and its energy resolution is compared to a commercial EASY-MCA 2K from AMETEK Inc.
The lung organ of human anatomy captured by a medical device reveals inhalation and exhalation information for treatment and monitoring. Given a large number of slices covering an area of the lung, we have a set of three‐dimensional lung data. And then, by combining additionally with breath‐hold measurements, we have a dataset of multigroup CT images (called 4DCT image set) that could show the lung motion and deformation over time. Up to now, it has still been a challenging problem to model a respiratory signal representing patients’ breathing motion as well as simulating inhalation and exhalation process from 4DCT lung images because of its complexity. In this paper, we propose a promising hybrid approach incorporating the local binary pattern (LBP) histogram with entropy comparison to register the lung images. The segmentation process of the left and right lung is completely overcome by the minimum variance quantization and within class variance techniques which help the registration stage. The experiments are conducted on the 4DCT deformable image registration (DIR) public database giving us the overall evaluation on each stage: segmentation, registration, and modeling, to validate the effectiveness of the approach.