20 March 2014 in EPJ Web of Conferences
CANDLES is the project to search for neutrino-less double beta decay (0νββ) of 48Ca. The observation of 0νββ will prove existence of a massive Majorana neutrino. For the 0νββ measurement, we need a low background condition because of a low decay rate of 0νββ. Now we installed the CANDLES III system at the Kamioka underground laboratory. The CANDLES III system realizes the low background condition by a characteristic structure and data analyses for background rejection. Here we report performances of the CANDLES III system.
10 September 2024 in IEEE Transactions on Nuclear Science
Pulse Shape Discrimination (PSD) techniques, particularly the widely employed charge integration ratio method (Q-ratio), have proven effective in discriminating fast neutrons from gamma rays in organic scintillation detectors. However, the effectiveness of Q-ratio diminishes in the low-energy region (below 150 keVee) due to overlapping signal, leading to a suboptimal Figure of Merit (FOM). In this study, we use machine learning (ML) technique, particularly the one-dimensional Convolutional Neural Network (1D-CNN), to enhance the neutron/gamma discrimination and compares the results with the traditional charge integration ratio in the low-energy region. Our investigation focuses on the EJ-276 plastic scintillator, a commercial product of ELJEN technology known for its good separation of gamma and fast neutron signals based on timing characteristics. Experimental data were acquired using 252 Cf and 60 Co radioisotope sources. A comprehensive comparative analysis between the traditional Q-ratio method and ML algorithms is conducted for the low energy region. Our main objective is to evaluate and enhance neutron/gamma discrimination capabilities of plastic scintillators in this low-energy region.
28 December 2020 in IEEE Transactions on Nuclear Science
In this study, we evaluated and compared the pulse shape discrimination (PSD) performance of a typical photomultiplier tube (PMT) with that of multi-pixel photon counters (MPPCs) also known as silicon photomultipliers (SiPMs). We used CsI(Tl) scintillators for both setups and mainly evaluated the PSD performance in the α-β separation. We used the charge comparison method, i.e., identifying the particle type based on the ratio of the charges collected in two time gates: Short Gate (SG) for the delayed part and Long Gate (LG) for the entire digitized waveform. With the same LG = 2250 ns, the PMT setup showed a better PSD performance with the figure of merit (FOM) being 3.33 (in α-β separation), whereas the FOM of the MPPC setup was 2.26. This inferior performance of the MPPC setup was due to the slow response, mainly the slow decay time in the waveform of one photoelectron (p.e.) of the MPPCs. This study aimed to determine the relationships of the PSD performance with the number of p.e. collected and the time characteristics of the scintillator-photosensor coupling. From these relationships, we estimated the SG to obtain FOMmax and afterward confirmed a method to further increase the PSD performance. The estimated SG gave a comparable FOM without an extensive search for the optimized SG for obtaining the actual FOMmax in analysis. To further increase the PSD performance of the MPPC setup, we used a new data acquisition (DAQ) system and extended the LG to 8000 ns to collect more p.e. and mitigate the slow response of the MPPCs. Using the new DAQ system, we obtained an FOM of 3.91 for the MPPC setup, i.e., an increase by a factor of 1.7.
3 March 2025 in IEEE Transactions on Nuclear Science
The Light only Liquid Xenon (LoLX) experiment is a prototype detector aimed to study liquid xenon (LXe) light properties and various photodetection technologies. LoLX is also aimed to quantify LXe’s time resolution as a potential scintillator for 10 ps time-of-flight positron emission tomography (TOF-PET). Another key goal of LoLX is to perform a time-based separation of Cerenkov and scintillation photons for new background rejection methods in LXe experiments. To achieve this separation, LoLX is set to be equipped with photon-to-digital converters (PDCs), a photosensor type that can provide a timestamp for each observed photon. To guide the PDC design, we explore the requirements and potential outcomes for time-based Cerenkov separation. We use a PDC simulator, whose input is the light information from the Geant4-based LoLX simulation model, and evaluate the separation quality against time-to-digital converter (TDC) parameters of the PDCs. Compared with the current filter-based approach, the simulations predict a few different configurations that offer a Cerenkov separation level increase from 50% to 66% when using PDCs and time-based separation. A separation of 65% is also achievable with just 16 TDCs for 14,400 micro-cells per PDC, or one TDC per 2.25 mm2. These simulation results will lead to a specification guide for the upcoming PDC design as well as expected results to compare against future PDC-based experimental measurements. In the longer term, the overall LoLX results will assist large LXe-based experiments and motivate the assembly of a LXe-based TOF-PET demonstrator system.