Lukasz Staszewski

Dr. Lukasz Staszewski

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2018 in Energies
Verified
Journal Article
Open access
PDF file
SKSunny Katyara
Sunny Katyara
LSLukasz Staszewski
Lukasz Staszewski
Zbigniew LeonowiczZbigniew Leonowicz
Zbigniew Leonowicz
The radial distribution networks are designed for unidirectional power flows and are passive in nature. However, with the penetration of Distributed Generation (DG), the power flow becomes bidirectional and the network becomes active. The integration of DGs into distribution network creates many issues with: system stability, protection coordination, power quality, islanding, proper placement and sizing etc. Among these issues, the two most significant are optimal sizing and placement of DGs and their protection coordination in utility network. The proper coordination of relays with high penetration of DGs placed at optimal location increases the availability and reliability of the network during abnormal operating conditions. This research addresses most of the available methods for efficient sizing and placement of DGs in distribution system (numerical, analytical and heuristic) as well as the developed protection coordination techniques for utility networks in the presence of DGs (Artificial Intelligence (AI), adaptive and non-adaptive, multi-agent, hybrid). This paper indicates the possible research gaps and highlights the applications possibilities and methods’ limitations in the area of DGs.

21 December 2020 in IEEE Access
Verified
Journal Article
Open access
Shoaib AhmedShoaib Ahmed
Shoaib Ahmed
SKSunny Katyara
Sunny Katyara
Abdul Majeed ShaikhAbdul Majeed Shaikh
Abdul Majeed Shaikh
ZKZahid H. Khand
Zahid H. Khand
LSLukasz Staszewski
Lukasz Staszewski
FAFaheem Akhtar
Faheem Akhtar
In the modern era of high-tech machines and advanced technologies, Pakistan yet fails to mitigate its daunting energy crisis and power shortage of $2765~MW$ presently, which eventually affects the economy and well-being of the nation. This article highlights and discusses the key issues in the energy sector of Pakistan and how they give rise to the load shedding, tariff rates and environmental damage subsequently. Unfortunately, the country has the highest power production share of 63.9% from thermal power plants and least of about $5-6\%$ from renewable sources. In contrast to renewable sources, the thermal power generation being exhaustible has many drawbacks such as rapid depletion of fossil fuel reserves, inevitable varying costs, shorter life expectancy and most notably the undesirable environmental impacts. In addition to all this, the transmission and distribution networks need to be upgraded to uplift the current carrying capacity of utility network otherwise may lead to the aging of system equipment, overloading of power and distribution transformers, increasing of power losses and many other factors contributing to the energy and economic concerns in the country. In the view of strategic analysis and detailed study made on the energy sector statistics, it is evident that Pakistan has promising potential of renewable energy resources especially solar, wind, and hydel to overcome the energy, economic and ecological problems in the country particularly and the region as a whole.

14 January 2021 in Electronics
Verified
Journal Article
Open access
PDF file
SKSunny Katyara
Sunny Katyara
Muhammad Fawad ShaikhMuhammad Fawad Shaikh
Muhammad Fawad Shaikh
Shoaib AhmedShoaib Ahmed
Shoaib Ahmed
ZKZahid Khand
Zahid Khand
LSLukasz Staszewski
Lukasz Staszewski
Zbigniew LeonowiczZbigniew Leonowicz
Zbigniew Leonowicz
With the rising load demand and power losses, the equipment in the utility network often operates close to its marginal limits, creating a dire need for the installation of new Distributed Generators (DGs). Their proper placement is one of the prerequisites for fully achieving the benefits; otherwise, this may result in the worsening of their performance. This could even lead to further deterioration if an effective Energy Management System (EMS) is not installed. Firstly, addressing these issues, this research exploits a Genetic Algorithm (GA) for the proper placement of new DGs in a distribution system. This approach is based on the system losses, voltage profiles, and phase angle jump variations. Secondly, the energy management models are designed using a fuzzy inference system. The models are then analyzed under heavy loading and fault conditions. This research is conducted on a six bus radial test system in a simulated environment together with a real-time Power Hardware-In-the-Loop (PHIL) setup. It is concluded that the optimal placement of a 3.33 MVA synchronous DG is near the load center, and the robustness of the proposed EMS is proven by mitigating the distinct contingencies within the approximately 2.5 cycles of the operating period.

3 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AHArif Hussain
Arif Hussain
AAArslan Ahmed
Arslan Ahmed
MSMadad Ali Shah
Madad Ali Shah
SKSunny Katyara
Sunny Katyara
LSLukasz Staszewski
Lukasz Staszewski
HMHina Magsi
Hina Magsi
Accurate, ubiquitous and reliable navigation can make transportation systems (road, rail, air and marine) more efficient, safer and more sustainable by enabling path planning, route optimization and fuel economy optimization. However, accurate navigation in urban contexts has always been a challenging task due to significant chances of signal blockage and multipath and non-line-of-sight (NLOS) signal reception. This paper presents a detailed study on environmental context detection using GNSS signals and its utilization in mitigating multipath effects by devising a context-aware navigation (CAN) algorithm that detects and characterizes the working environment of a GNSS receiver and applies the desired mitigation strategy accordingly. The CAN algorithm utilizes GNSS measurement variables to categorize the environment into standard, degraded and highly degraded classes and then updates the receiver’s tracking-loop parameters based on the inferred environment. This allows the receiver to adaptively mitigate the effects of multipath/NLOS, which inherently depend upon the type of environment. To validate the functionality and potential of the proposed CAN algorithm, a detailed study on the performance of a multi-GNSS receiver in the quad-constellation mode, i.e., GPS, BeiDou, Galileo and GLONASS, is conducted in this research by traversing an instrumented vehicle around an urban city and acquiring respective GNSS signals in different environments. The performance of a CAN-enabled GNSS receiver is compared with a standard receiver using fundamental quality indicators of GNSS. The experimental results show that the proposed CAN algorithm is a good contributor for improving GNSS performance by anticipating the potential degradation and initiating an adaptive mitigation strategy. The CAN-enabled GNSS receiver achieved a lane-level accuracy of less than 2 m for 53% of the total experimental time-slot in a highly degraded environment, which was previously only 32% when not using the proposed CAN.

12 October 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
SKSunny Katyara
Sunny Katyara
LSLukasz Staszewski
Lukasz Staszewski
Zbigniew LeonowiczZbigniew Leonowicz
Zbigniew Leonowicz
The radial distribution networks are designed for unidirectional power flows and are passive in nature. However, with the penetration of Distributed Generation (DG), the power flow becomes bidirectional and the network becomes active. The integration of DGs into distribution network creates many issues with: system stability, protection coordination, power quality, islanding, proper placement and sizing etc. Among these issues, the two most significant are optimal sizing and placement of DGs and their protection coordination in utility network. The proper coordination of relays with high penetration of DGs placed at optimal location increases the availability and reliability of the network during abnormal operating conditions.This research addresses most of the available methods for efficient sizing and placement of DGs in distribution system (numerical, analytical and heuristic) as well as the developed protection coordination techniques for utility networks in the presence of DGs (Artificial Intelligence (AI), adaptive and non-adaptive, multi-agent, hybrid). This paper indicates the possible research gaps and highlights the applications possibilities and methods’ limitations in the area of DGs.

20 September 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Muhammad Fawad ShaikhMuhammad Fawad Shaikh
Muhammad Fawad Shaikh
SKSunny Katyara
Sunny Katyara
ZKZahid Khand
Zahid Khand
MSMadad Ali Shah
Madad Ali Shah
LSLukasz Staszewski
Lukasz Staszewski
Zbigniew LeonowiczZbigniew Leonowicz
Zbigniew Leonowicz
Distribution networks are inherently radial and passive owing to the ease of operation and unidirectional power flow. Proper installation of Distributed Generators, on the one hand, makes the utility network active and mitigates certain power quality issues e.g., voltage dips, frequency deviations, losses, etc., but on the other hand, it disturbs the optimal coordination among existing protection devices e.g., over-current relays. In order to maintain the desired selectivity level, such that the primary and backup relays are synchronized against different contingencies, it necessitates design of intelligent and promising protection schemes to distinguish between the upstream and downstream power flows. This research proposes exploiting phase angle jump, an overlooked voltage sag parameter, to add directional element to digital over-current relays with inverse time characteristics. The decision on the direction of current is made on the basis of polarity of phase angle jump together with the impedance angle of the system. The proposed scheme at first is evaluated on a test system in a simulated environment under symmetrical and unsymmetrical faults and, secondly, as a proof of the concept, it is verified in real-time on a laboratory setup using a Power Hardware-in-loop (PHIL) system. Moreover, a comparative analysis is made with other state-of-the-art techniques to evaluate the performance and robustness of the proposed approach.