Gunther Notni

Dr. Gunther Notni

Group for Quality Assurance and Image Processing, Technical University Ilmenau, 98684 Ilmenau, Germany
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Christian Bräuer-BurchardtChristian Bräuer-Burchardt
Christian Bräuer-Burchardt
CMChristoph Munkelt
Christoph Munkelt
MBMichael Bleier
Michael Bleier
MHMatthias Heinze
Matthias Heinze
IGIngo Gebhart
Ingo Gebhart
GNGunther Notni
Gunther Notni
Three-dimensional capturing of underwater archeological sites or sunken shipwrecks can support important documentation purposes. In this study, a novel 3D scanning system based on structured illumination is introduced, which supports cultural heritage documentation and measurement tasks in underwater environments. The newly developed system consists of two monochrome measurement cameras, a projection unit that produces aperiodic sinusoidal fringe patterns, two flashlights, a color camera, an inertial measurement unit (IMU), and an electronic control box. The opportunities and limitations of the measurement principles of the 3D scanning system are discussed and compared to other 3D recording methods such as laser scanning, ultrasound, and photogrammetry, in the context of underwater applications. Some possible operational scenarios concerning cultural heritage documentation are introduced and discussed. A report on application activities in water basins and offshore environments including measurement examples and results of the accuracy measurements is given. The study shows that the new 3D scanning system can be used for both the topographic documentation of underwater sites and to generate detailed true-scale 3D models including the texture and color information of objects that must remain under water.

23 December 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Christian Bräuer-BurchardtChristian Bräuer-Burchardt
Christian Bräuer-Burchardt
MHMatthias Heinze
Matthias Heinze
ISIngo Schmidt
Ingo Schmidt
PKPeter Kühmstedt
Peter Kühmstedt
GNGunther Notni
Gunther Notni
In this work we show the principle of optical 3D surface measurements based on the fringe projection technique for underwater applications. The challenges of underwater use of this technique are shown and discussed in comparison with the classical application. We describe an extended camera model which takes refraction effects into account as well as a proposal of an effective, low-effort calibration procedure for underwater optical stereo scanners. This calibration technique combines a classical air calibration based on the pinhole model with ray-based modeling and requires only a few underwater recordings of an object of known length and a planar surface. We demonstrate a new underwater 3D scanning device based on the fringe projection technique. It has a weight of about 10 kg and the maximal water depth for application of the scanner is 40 m. It covers an underwater measurement volume of 250 mm × 200 mm × 120 mm. The surface of the measurement objects is captured with a lateral resolution of 150 μm in a third of a second. Calibration evaluation results are presented and examples of first underwater measurements are given.

12 November 2020 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
CZChen Zhang
Chen Zhang
IGIngo Gebhart
Ingo Gebhart
PKPeter Kühmstedt
Peter Kühmstedt
MRMaik Rosenberger
Maik Rosenberger
GNGunther Notni
Gunther Notni
The contactless estimation of vital signs using conventional color cameras and ambient light can be affected by motion artifacts and changes in ambient light. On both these problems, a multimodal 3D imaging system with an irritation-free controlled illumination was developed in this work. In this system, real-time 3D imaging was combined with multispectral and thermal imaging. Based on 3D image data, an efficient method was developed for the compensation of head motions, and novel approaches based on the use of 3D regions of interest were proposed for the estimation of various vital signs from multispectral and thermal video data. The developed imaging system and algorithms were demonstrated with test subjects, delivering a proof-of-concept.

19 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DSDominik Schraml
Dominik Schraml
GNGunther Notni
Gunther Notni
Industrial-quality inspections, particularly those leveraging AI, require significant amounts of training data. In fields like injection molding, producing a multitude of defective parts for such data poses environmental and financial challenges. Synthetic training data emerge as a potential solution to address these concerns. Although the creation of realistic synthetic 2D images from 3D models of injection-molded parts involves numerous rendering parameters, the current literature on the generation and application of synthetic data in industrial-quality inspection scarcely addresses the impact of these parameters on AI efficacy. In this study, we delve into some of these key parameters, such as camera position, lighting, and computational noise, to gauge their effect on AI performance. By utilizing Blender software, we procedurally introduced the “flash” defect on a 3D model sourced from a CAD file of an injection-molded part. Subsequently, with Blender’s Cycles rendering engine, we produced datasets for each parameter variation. These datasets were then used to train a pre-trained EfficientNet-V2 for the binary classification of the “flash” defect. Our results indicate that while noise is less critical, using a range of noise levels in training can benefit model adaptability and efficiency. Variability in camera positioning and lighting conditions was found to be more significant, enhancing model performance even when real-world conditions mirror the controlled synthetic environment. These findings suggest that incorporating diverse lighting and camera dynamics is beneficial for AI applications, regardless of the consistency in real-world operational settings.

31 January 2012 in Optics Express
Verified
Journal Article
Open access
PDF file
SZS. Zwick
S. Zwick
RFR. Feßler
R. Feßler
JJJ. Jegorov
J. Jegorov
GNGunther Notni
Gunther Notni
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

10 November 2016
Verified
Conference Paper
Closed access
CZChen Zhang
Chen Zhang
MRMaik Rosenberger
Maik Rosenberger
ABAndreas Breitbarth
Andreas Breitbarth
GNGunther Notni
Gunther Notni
The combination of the multispectral imaging and the 3D imaging in one system would render possible varieties of applications in different fields. In this work a method is proposed for the registration of multispectral data and 3D point cloud, in which the number of spectral bands is increased by combining different multispectral images through 3D information. Based on this method, a 3D multispectral imaging system consisting of two filter wheel cameras and a digital projector is developed. This system can provide maximally 23 spectral bands with a short acquisition duration of ca. 1.5 seconds and achieve a data fusion accuracy of 15 µm for a measurement field of 128 mm × 145 mm. Furthermore, there exists a significant potential to extend the spectral range and raise the spectral resolution by integrating additional cameras with the proposed data fusion principle.