Recently, the incidence of, and interest in, respiratory diseases has been amplified by severe acute respiratory syndrome coronavirus (SARS-CoV-2) and other respiratory diseases with a high prevalence. Most of these diseases require mechanical ventilation for homecare and clinical therapy. Herein, we propose a portable and non-invasive mechanical fan (NIV) for home and clinical applications. The NIV’s core is a turbine for airflow generation, which can provide and monitor a positive two-level pressure of up to approximately 500 lpm at 50 cmH2O according to the inspiration/expiration phase. After calibration, the proposed NIV can precisely set the airflow with a pressure between 4 cmH2O and 20 cmH2O, providing a versatile device that can be used for continuous positive airway pressure (CPAP) or bilevel positive airway pressure (BiPAP). The airflow is generated by a turbine monitored using a mass flow sensor. The whole NIV is monitored with a 16 MHz clock microcontroller. An analog-to-digital converter is used as the input for analog signals, while a digital-to-analog converter is used to drive the turbine. I2C protocol signals are used to manage the display. Moreover, a Wi-Fi system is interfaced for the transmission/reception of clinical and technical information via a smartphone, achieving a remote-controlled NIV.
The development of even more compact, inexpensive, and highly sensitive gas sensors is widespread, even though their performances are still limited and technological improvements are in continuous evolution. Zeolite is a class of material which has received particular attention in different applications due to its interesting adsorption/desorption capabilities. The behavior of a zeolite 4A modified capacitor has been investigated for the adsorption of nitrogen (N2), nitric oxide (NO) and 1,1-Difluoroethane (C2H4F2), which are of interest in the field of chemical, biological, radiological, and nuclear threats. Sample measurements were carried out in different environmental conditions, and the variation of the sensor electric capacitance was investigated. The dielectric properties were influenced by the type and concentration of gas species in the environment. Higher changes in capacitance were shown during the adsorption of dry air (+4.2%) and fluorinated gas (+7.3%), while lower dielectric variations were found upon exposure to N2 (−0.4%) and NO (−0.5%). The proposed approach pointed-out that a simple fabrication process may provide a convenient and affordable fabrication of reusable capacitive gas sensor.
Low frequency ultrasounds in air are widely used for real-time applications in short-range communication systems and environmental monitoring, in both structured and unstructured environments. One of the parameters widely evaluated in pulse-echo ultrasonic measurements is the time of flight (TOF), which can be evaluated with an increased accuracy and complexity by using different techniques. Hereafter, a nonstandard cross-correlation method is investigated for TOF estimations. The procedure, based on the use of template signals, was implemented to improve the accuracy of recursive TOF evaluations. Tests have been carried out through a couple of 60 kHz custom-designed polyvinylidene fluoride (PVDF) hemicylindrical ultrasonic transducers. The experimental results were then compared with the standard threshold and cross-correlation techniques for method validation and characterization. An average improvement of 30% and 19%, in terms of standard error (SE), was observed. Moreover, the experimental results evidenced an enhancement in repeatability of about 10% in the use of a recursive positioning system.