Sung-Jae Lee

Dr. Sung-Jae Lee


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
JSJeong-Hee Seo
Jeong-Hee Seo
MKMin-Seok Kim
Min-Seok Kim
JLJeong-Hyeon Lee
Jeong-Hyeon Lee
EEEmmanuel Eghan-Acquah
Emmanuel Eghan-Acquah
YJYong-Hoon Jeong
Yong-Hoon Jeong
SLSung-Jae Lee
Sung-Jae Lee
Orthodontic treatment increasingly involves transparent aligners; however, biomechanical analysis of their treatment effects under clinical conditions is lacking. We compared the biomechanical efficacy and effectiveness of orthodontic treatment with transparent aligners and of fixed appliances in simulated clinical orthodontic treatment conditions using orthodontic finite element (FE) models. In the FE analysis, we used Model Activation/De-Activation analysis to validate our method. Fixed appliances and 0.75-mm and 0.5-mm thick transparent aligners were applied to a tooth-alveolar bone FE model with lingually-inclined and axially-rotated central incisors. Compared to the fixed appliance, the 0.75-mm and 0.5-mm transparent aligners induced 5%, 38%, and 28% and 21%, 62%, and 34% less movement of the central incisors and principal stress of the periodontal ligament and of the alveolar bone, respectively, for lingual inclination correction. For axial-rotation correction, these aligners induced 22%, 37%, and 40% and 28%, 67%, and 48% less tooth movement and principal stress of the periodontal ligament and of the alveolar bone, respectively. In conclusion, transparent aligners induced less tooth movement, it is sufficient for orthodontic treatment, but 0.5-mm aligners should be used for only mild corrections. Additionally, the Model Activation/De-Activation analysis method is suitable for FE analysis of orthodontic treatment reflecting clinical treatment conditions.

14 August 2019 in Antioxidants
Verified
Journal Article
Open access
PDF file
Bongju KIMBongju KIM
Bongju KIM
SLSung-Ho LEE
Sung-Ho LEE
SSSu-Jin Song
Su-Jin Song
WKWon-Hyeon Kim
Won-Hyeon Kim
ESeunsung song
eunsung song
JLJong-Ho Lee
Jong-Ho Lee
A polyphenolic extract from melon (Cucumis melo L.), as a potential source of natural antioxidants, has been reported to have a positive effect on osteoblast activity. In this study, the protective effects of heat-treated melon extract (ECO-A) on bone strength, mineralization, and metabolism were examined in osteoporotic rat models. Osteoporosis was induced by ovariectomy (OVX) in female rats and then maintained for 8 weeks, along with the ingestion of phosphate-buffered saline (PBS, OVXP) or ECO-A (OVXE) for an additional 4 weeks. At a pre-determined timepoint, bone strengths, as well as bone mineral contents (BMC) and the density (BMD) of femurs and/or lumbar spines extracted from each animal, were measured by a mechanical test and dual-energy X-ray absorptiometry, respectively. Moreover, several biochemical markers for bone turnover were analyzed by respective colorimetric assay kits in addition to clinical analyses. The maximum load and stiffness of femurs from the OVXE group were found to be significantly higher than the other groups. Furthermore, the OVXE group showed significantly higher BMC, BMD, and bone volume than the OVX and OVXP groups, which were comparable to the non-OVX (sham) group. The levels of bone formation and resorption markers in the OVXE group were similar to the sham group, but significantly different from other groups. In conclusion, these results suggest that ECO-A can play potentially positive roles in the protection of bone loss in rats with OVX-induced osteoporosis.

29 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
JLJeong-Hyeon Lee
Jeong-Hyeon Lee
JSJeong-Hee Seo
Jeong-Hee Seo
SPShin-Wook Park
Shin-Wook Park
WKWon-Gi Kim
Won-Gi Kim
TJTae-Gon Jung
Tae-Gon Jung
SLSung-Jae Lee
Sung-Jae Lee
The purposes of this study are to establish and validate a finite element (FE) model using finite element analysis methods and to identify optimal loading conditions to simulate masticatory movement. A three-dimensional FE model of the maxillary and mandibular cortical bone, cancellous bone, and gingiva was constructed based on edentulous cone-beam-computed tomography data. Dental computer-aided design software was used to design the denture base and artificial teeth to produce a complete denture. Mesh convergence was performed to derive the optimal mesh size, and validation was conducted through comparison with mechanical test results. The mandible was rotated step-by-step to induce movements similar to actual mastication. Results showed that there was less than a 6% difference between the mechanical test and the alveolar bone-complete denture. It opened 10° as set in the first stage, confirming that the mouth closed 7° in the second stage. Occlusal contact occurred between the upper and lower artificial teeth as the mouth closed the remaining angle of 3° in the third stage while activating the masseter muscle. These results indicate that the FE model and masticatory loading conditions developed in this study can be applied to analyze biomechanical effects according to the wearing of dentures with various design elements applied.

15 September 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YYYong-Cheol Yoon
Yong-Cheol Yoon
SLSung-Jae Lee
Sung-Jae Lee
HSHyung Keun Song
Hyung Keun Song
Background/Objectives: The combined effect of femoral neck–shaft angle and lag screw position on unstable intertrochanteric fracture fixation has not been well established. This biomechanical study evaluated the effects of two caput–collum–diaphyseal (CCD) angles and two lag screw positions on construct stability. Methods: Twenty-four synthetic femurs with identical AO/OTA 31-A2.2 fracture gaps (2 mm) were fixed using cephalomedullary nails with CCD angles of either 125° or 130°, each with a central or inferior (calcar) lag screw (n = 6/group). Constructs were tested in a single-leg stance under preloading, cyclic loading (75–750 N, 10,000 cycles, and 2 Hz), and axial loading to failure. Lag screw migration was measured radiographically, and femoral head rotation was recorded using a three-dimensional coordinate-measuring device. Stiffness, failure load, and rotations were compared using the Kruskal–Wallis and Bonferroni post hoc tests. Results: The 125° inferior configuration showed the highest stiffness (188 ± 15 N/mm, p = 0.038) and failure load (1350 ± 97 N, p = 0.047), with the least screw migration (0.54 ± 0.11 mm, p = 0.003), significantly outperforming the 125° central and 130° central constructs. However, it exhibited greater varus collapse (2.25 ± 0.27°, p = 0.013) and axial rotation (~20–30% higher than others, p = 0.025). Screw position had a stronger effect on stability than the CCD angle, although the 130° inferior construct showed slightly less varus deformation. Conclusions: An inferior calcar-guided lag screw improves fixation strength and stiffness in unstable intertrochanteric fractures, particularly in those with a 125° nail. However, this configuration increases varus and rotational displacement, warranting adjunct measures to enhance rotational control in clinical applications.

1 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
JSJae Won Shin
Jae Won Shin
DKDaehyeon Kim
Daehyeon Kim
KKKi Mun Kang
Ki Mun Kang
TPTae Hyun Park
Tae Hyun Park
YOyurim Oh
yurim Oh
BLByung Ho Lee
Byung Ho Lee
Background: Multilevel posterior spinal fusion to T10 often encounters complications such as screw loosening and proximal junctional kyphosis. Cement augmentation or prophylactic vertebroplasty is used to prevent these, but their biomechanical effects remain unclear. Methods: A validated finite element model (T8–pelvis) from CT data of a 57-year-old male was tested in five configurations: fusion only, fusion with cement augmentation at T10, T10–T11, T10–T11 plus T9 vertebroplasty, and T10–T11 plus T8–T9 vertebroplasty. Range of motion (ROM), intradiscal pressure (IDP), posterior ligament/facet stress, and cement–bone interface stresses were analyzed under a 400 N follower load and 10 N·m moments. Results: Cement augmentation at the upper instrumented vertebra produced <5% changes in ROM, IDP, and posterior ligament/facet stresses compared with fusion only, indicating preserved stability. Prophylactic vertebroplasty redistributed stress proximally, with elevated cement–bone interface stresses localized at T9 when vertebroplasty was performed at a single adjacent level (T9) and distributed to both T8 and T9 when performed at two adjacent levels (T8–9)—with T9 stressed mainly during lateral bending and extension, and T8 during flexion and lateral bending. Conclusion: Cement augmentation alone did not compromise adjacent-level biomechanics, but prophylactic vertebroplasty created abnormal stress concentrations at adjacent interfaces, potentially increasing fracture risk. These findings highlight the need for careful patient selection and further studies in osteoporotic populations.

27 March 2024 in Journal of International Medical Research
Verified
Journal Article
Open access
SOSeog-Hyun Oh
Seog-Hyun Oh
YSYu-Sung Suh
Yu-Sung Suh
EEEmmanuel Eghan-Acquah
Emmanuel Eghan-Acquah
KYKollerov Mikhail Yurevich
Kollerov Mikhail Yurevich
SWSung-Hun Won
Sung-Hun Won
SCSung-woo Choi
Sung-woo Choi
Background: To compare the biomechanical stability of a novel, C-shaped nickel–titanium shape memory alloy (SMA) implant (C-clip) with traditional cerclage wiring in the fixation of a Vancouver B1 (VB1) periprosthetic femoral fracture (PFF). Methods: In total, 18 synthetic femoral fracture models were constructed to obtain unstable VB1 fracture with an oblique fracture line 8 cm below the lesser trochanter. For each model, the distal portion was repaired using a 10-hole locking plate and four distal bi-cortical screws. The proximal portion was repaired using either three, threaded cerclage wirings or three, novel C-shaped implants. Specimens underwent biomechanical testing using axial compression, torsional and four-point bending tests. Each test was performed on three specimens. Results: The C-clip was statistically significantly stronger (i.e., stiffer) than cerclage wiring in the three biomechanical tests. For axial compression, medians (ranges) were 39 (39–41) and 35 (35–35) N/mm, for the C-clip and cerclage wiring, respectively. For torsion, medians (ranges) were, 0.44 (0.44–0.45) and 0.30 (0.30–0.33) N/mm for the C-clip and cerclage wiring, respectively. For the four-point bending test, medians (ranges) were 39 (39–41) and 28 (28–31) N/mm; for the C-clip and cerclage wiring, respectively. Conclusion: Results from this small study show that the novel, C-shaped SMA appears to be biomechanically superior to traditional cerclage wiring in terms of stiffness, axial compression, torsion and four-point bending, and may be a valuable alternative in the repair of VB1 PFF. Further research is necessary to support these results.