Emmanuel Eghan-Acquah

Mr. Emmanuel Eghan-Acquah

Griffith University, Brisbane, Queensland, Australia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2021 in Materials
Verified
Journal Article
Open access
PDF file
JSJeong-Hee Seo
Jeong-Hee Seo
EEEmmanuel Eghan-Acquah
Emmanuel Eghan-Acquah
MKMin-Seok Kim
Min-Seok Kim
JLJeong-Hyeon Lee
Jeong-Hyeon Lee
JYJeong yonghoon
Jeong yonghoon
SLSung-Jae Lee
Sung-Jae Lee
Lately, in orthodontic treatments, the use of transparent aligners for the correction of malocclusions has become prominent owing to their intrinsic advantages such as esthetics, comfort, and minimal maintenance. Attempts at improving upon this technology by varying various parameters to investigate the effects on treatments have been carried out by several researchers. Here, we aimed to investigate the biomechanical and clinical effects of aligner thickness on stress distributions in the periodontal ligament and changes in the tooth’s center of rotation. Dental finite element models comprising the cortical and cancellous bones, gingiva, teeth, and nonlinear viscoelastic periodontal ligaments were constructed, validated, and used together with aligner finite element models of different aligner thicknesses to achieve the goal of this study. The finite element analyses were conducted to simulate the actual orthodontic aligner treatment process for the correction of malocclusions by generating pre-stresses in the aligner and allowing the aligner stresses to relax to induce tooth movement. The results of the analyses showed that orthodontic treatment in lingual inclination and axial rotation with a 0.75 mm-thick aligner resulted in 6% and 0.03% higher principal stresses in the periodontal ligament than the same treatment using a 0.05 mm-thick aligner, respectively. Again, for both aligner thicknesses, the tooth’s center of rotation moved lingually and towards the root direction in lingual inclination, and diagonally from the long axis of the tooth in axial rotation. Taken together, orthodontic treatment for simple malocclusions using transparent aligners of different thicknesses will produce a similar effect on the principal stresses in the periodontal ligament and similar changes in the tooth’s center of rotation, as well as sufficient tooth movement. These findings provide orthodontists and researchers clinical and biomechanical evidence about the effect of transparent aligner thickness selection and its effect on orthodontic treatment.

30 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
KHkyougnjae Hong
kyougnjae Hong
WKWon-Hyeon Kim
Won-Hyeon Kim
EEEmmanuel Eghan-Acquah
Emmanuel Eghan-Acquah
JLJong-Ho Lee
Jong-Ho Lee
BLBu-Kyu Lee
Bu-Kyu Lee
Bongju KIMBongju KIM
Bongju KIM
Clear aligner technology has become the preferred choice of orthodontic treatment for malocclusions for most adult patients due to their esthetic appeal and comfortability. However, limitations exist for aligner technology, such as corrections involving complex force systems. Composite attachments on the tooth surface are intended to enable active control of tooth movements. However, unintended tooth movements still occur. In this study, we present an effective attachment design of an attachment that can efficiently induce tooth movement by comparing and analyzing the movement and rotation of teeth between a general attachment and an overhanging attachment. The 3D finite element modes were constructed from CBCT data and used to analyze the distal displacement of the central incisor using 0.5- and 0.75-mm-thick aligners without an attachment, and with general and overhanging attachments. The results show that the aligner with the overhanging attachment can effectively reduce crown tipping and prevent axial rotation for an intended distal displacement of the central incisor. In all models, an aligner with or without attachments was not capable of preventing the lingual inclination of the tooth.

26 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
JSJeong-Hee Seo
Jeong-Hee Seo
MKMin-Seok Kim
Min-Seok Kim
JLJeong-Hyeon Lee
Jeong-Hyeon Lee
EEEmmanuel Eghan-Acquah
Emmanuel Eghan-Acquah
YJYong-Hoon Jeong
Yong-Hoon Jeong
SLSung-Jae Lee
Sung-Jae Lee
Orthodontic treatment increasingly involves transparent aligners; however, biomechanical analysis of their treatment effects under clinical conditions is lacking. We compared the biomechanical efficacy and effectiveness of orthodontic treatment with transparent aligners and of fixed appliances in simulated clinical orthodontic treatment conditions using orthodontic finite element (FE) models. In the FE analysis, we used Model Activation/De-Activation analysis to validate our method. Fixed appliances and 0.75-mm and 0.5-mm thick transparent aligners were applied to a tooth-alveolar bone FE model with lingually-inclined and axially-rotated central incisors. Compared to the fixed appliance, the 0.75-mm and 0.5-mm transparent aligners induced 5%, 38%, and 28% and 21%, 62%, and 34% less movement of the central incisors and principal stress of the periodontal ligament and of the alveolar bone, respectively, for lingual inclination correction. For axial-rotation correction, these aligners induced 22%, 37%, and 40% and 28%, 67%, and 48% less tooth movement and principal stress of the periodontal ligament and of the alveolar bone, respectively. In conclusion, transparent aligners induced less tooth movement, it is sufficient for orthodontic treatment, but 0.5-mm aligners should be used for only mild corrections. Additionally, the Model Activation/De-Activation analysis method is suitable for FE analysis of orthodontic treatment reflecting clinical treatment conditions.

30 October 2024 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
EEEmmanuel Eghan-Acquah
Emmanuel Eghan-Acquah
ABAlireza Y Bavil
Alireza Y Bavil
DBDavid Bade
David Bade
MBMartina Barzan
Martina Barzan
ANAzadeh Nasseri
Azadeh Nasseri
CCChristopher P. Carty
Christopher P. Carty
Proximal femoral osteotomy (PFO) is a frequently performed surgical procedure to correct hip deformities in the paediatric population. The optimal size of the blade plate implant in PFO is a critical but underexplored factor influencing biomechanical outcomes. This study introduces a novel approach to refine implant selection by integrating personalized neuromusculoskeletal modelling with finite element analysis. Using computed tomography scans and walking gait data from six paediatric patients with various pathologies and deformities, we assessed the impact of four distinct implant width-to-femoral neck diameter (W-D) ratios (30 %, 40 %, 50 %, and 60 %) on surgical outcomes. The results show that the risk of implant yield generally decreases with increasing W-D ratio, except for Patient P2, where the yield risk remained below 100 % across all ratios. The implant factor of safety (FoS) increased with larger W-D ratios, except for Patients P2 and P6, where the highest FoS was 2.60 (P2) and 0.49 (P6) at a 60 % W-D ratio. Bone-implant micromotion consistently remained below 40 µm at higher W-D ratios, with a 50 % W-D ratio striking the optimal balance for mechanical stability in all patients except P6. Although interfragmentary and principal femoral strains did not display consistent trends across all patients, they highlight the need for patient-specific approaches to ensure effective fracture healing. These findings highlight the importance of patient-specific considerations in implant selection, offering surgeons a more informed pathway to enhance patient outcomes and extend implant longevity. Additionally, the insights gained from this study provide valuable guidance for manufacturers in designing next-generation blade plates tailored to improve biomechanical performance in paediatric orthopaedics.

15 December 2024 in Computers in Biology and Medicine
Verified
Journal Article
Open access
ABAlireza Y. Bavil
Alireza Y. Bavil
EEEmmanuel Eghan-Acquah
Emmanuel Eghan-Acquah
ADAyda Karimi Dastgerdi
Ayda Karimi Dastgerdi
LDLaura E. Diamond
Laura E. Diamond
RBRod Barrett
Rod Barrett
CCChristopher P. Carty
Christopher P. Carty
Proximal femoral osteotomy (PFO) is a surgical intervention, typically performed on paediatric population, that aims to correct femoral deformities caused by different pathologies (e.g., slipped capital femoral epiphysis). A PFO involves introduction of an implant to fix the proximal and distal sections of femur following the surgical corrections. The femoral neck-shaft angle (NSA) and anteversion angle (AVA) are key geometric parameters that influence PFO outcomes. To date, the effects of NSA and AVA on bone-implant system mechanics in paediatric populations have not been examined. This study used an established neuromusculoskeletal modelling process paired with finite element analysis to determine the sensitivity of the implanted femur's mechanics to variations in NSA and AVA during the stance phase of walking. Three male patients aged 9-12 years with different pathology (Spastic diplegia, Perthes disease and Slipped Capital Femoral Epiphysis), weight (377, 747, 842 N), height (1.39, 1.55, 1.71 m) and femur lengths (34.1, 39.4, 43.7 cm) and geometries (NSA: 143, 102, 111 deg; AVA: 29, 17, -22 deg) were examined. For each patient, a three-dimensional bone model was created from computed tomography imaging and digital surgical corrections were applied to systematically vary the NSA and AVA. Personalized motion and loading conditions driven from a neuromusculoskeletal modelling process were applied to each model and its associated permutations of NSA and AVA. Results indicated significant intra-participant variability in post-PFO bone-implant micromotion and peak von Mises stress on implant. For models with a post-surgery NSA of 135° and AVA of 12°, the averaged micromotion increased by 87 % and the peak von Mises stress decreased by 63% between patient 1 and 2. Between patient 2 and 3, the averaged micromotion decreased by 55% while the peak von Mises stress increased by 84%. Furthermore, post-PFO bone-implant mechanics were sensitive to variation in NSA and AVA in a subject-specific manner. Optimization of PFO planning is recommended based on patient-specific characteristics.

30 January 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
EEEmmanuel Eghan-Acquah
Emmanuel Eghan-Acquah
ABAlireza Y. Bavil
Alireza Y. Bavil
LDLaura E. Diamond
Laura E. Diamond
RBRod Barrett
Rod Barrett
CCChristopher P. Carty
Christopher P. Carty
SFStefanie Feih
Stefanie Feih
Finite element analysis (FEA) is nowadays a pivotal tool in orthopaedic research for personalized virtual surgery planning. Despite its widespread use, a comprehensive evaluation of the effect of boundary conditions on the simulation of physiological mechanics in implanted bone is currently lacking. This study assesses the impact of boundary conditions and femur geometry on predicted femur mechanics. It focuses on an isolated implanted femur, partially imaged, from a paediatric patient with femoral varus who underwent a proximal femoral osteotomy. By employing FEA of the femur under motion with loading scenarios informed by personalized neuromusculoskeletal modelling, this study evaluated implant and bone mechanics across three femur model configurations (full-femur, proximal half-femur, and distally synthesized full-femur) with two boundary condition approaches (biomechanical and fixed distal). The biomechanical boundary condition was validated against the gold standard inertia relief method for the natural femur and thereafter exploited as the benchmark against the other implanted femur model configurations. The distally synthesized full-femur with biomechanical boundary conditions performed best and closely predicted bone-implant micromotion (R2 = 0.99, nRMSE = 0.3%), risk of implant yield (<1% variance from the benchmark model), and interfragmentary movement (R2 = 1, nRMSE = 6%). The half-femur model with biomechanical boundary conditions overpredicted the risk of yield and interfragmentary movements by 17% and 15.8%, respectively. The fixed distal constraint method significantly overestimated the risk of implant yield in both half and synthesized full-femur models by 157% and 170%, respectively. These findings underscore the critical importance of selecting appropriate boundary conditions in the FEA of implanted femur models and advocate for the synthesis of the missing portion of the femur coupled with the biomechanical boundary conditions for more accurate predictions of bone and implant mechanics. Such insights are expected to enhance the physiological plausibility and reliability of orthopaedic research and clinical practices, especially when managing proximal femoral osteotomies.