Frequency response analysis (FRA) is a popular method for assessing a transformer’s mechanical condition. The paper proposes a new method for interpreting the frequency response measurement results. The currently used numerical indices only give one value, which may be misleading in the analysis, while the proposed frequency response quality index (FRQI) tool analyses three separate features in the whole frequency range. The applied numerical calculations technique allows for estimations of not only the values of the average quality indices, but also locally for given frequency ranges of the analysed spectrum. It allows for determination of the problems that can be found in the active part of a transformer. The presented results come from three transformers, representing cases of typical faults. Two of them are from industry, while one was used for deformational tests in laboratory conditions. The proposed FRQI method showed its usefulness in FRA test results analysis and may be introduced into the automated assessment of such data. Each of the component parameters is sensitive to other types of differences observed between the compared frequency response curves, and may be used as a good quality detection tool.

16 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
RKRobert Krupiński
Robert Krupiński
EKEugeniusz Kornatowski
Eugeniusz Kornatowski
Vibroacoustic diagnostics (VM—Vibroacoustic Method) is one of the methods for diagnosing the active part of power transformers. Measurement technologies have been refined over the past several years, but the methods of analyzing data obtained in VM diagnostics are still in development. In most cases, they are based on a simple frequency spectrum analysis, and the diagnostic conclusions are subjective and depend on the expert’s professional experience. The article presents an objective method for the detection of transformer unit core damage, based on the analysis of the statistical properties of the vibration signal registered on the surface of the tank of an unloaded transformer in the steady state of vibrations (VM). The algorithm for proceeding further is: FFT analysis of the vibroacoustic signal, with the determination of the relative changes in vibration power as a function of frequency P r ( f ) and, finally, the determination of the statistic properties of the dataset P r ( f ) . The Generalized Gaussian Distribution (GGD) is used to describe the P r ( f ) set. The detector output values are the λ and p parameters of the GGD distribution. These two numerical values form the basis for the classification of the technical condition of the transformer unit core. The correctness of the described solution was verified on the example of ten pieces of 16 MVA power transformers with different operating times and degrees of wear.

11 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
SBSzymon Banaszak
Szymon Banaszak
EKEugeniusz Kornatowski
Eugeniusz Kornatowski
Wojciech SzokaWojciech Szoka
Wojciech Szoka
Frequency response analysis is a method used in transformer diagnostics for the detection of mechanical faults or short-circuits in windings. The interpretation of test results is often performed with the application of numerical indices. However, usually these indices are used for the whole frequency range of the recorded data, returning a single number. Such an approach is inaccurate and may lead to mistakes in the interpretation. An alternative quality assessment is based on the estimation of the local values of the quality index with the moving window method. In this paper, the authors analyse the influence of the width of the input data window for four numerical indices. The analysis is based on the data measured on the transformer with deformations introduced into the winding and also for a 10 MVA transformer measured under industrial conditions. For the first unit the analysis is performed for various window widths and for various extents of the deformation, while in the case of the second the real differences between the frequency response curves are being analysed. On the basis of the results it was found that the choice of the data window width significantly influences the quality of the analysis results and the rules for elements number selection differ for various numerical indices.

16 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
EKEugeniusz Kornatowski
Eugeniusz Kornatowski
SBSzymon Banaszak
Szymon Banaszak
PMPaweł Molenda
Paweł Molenda
The paper describes the application of the numerical tool quality index for an objective evaluation of complementary frequency response analysis (FRA) and vibroacoustic method (VM) test methods. These diagnostic methods are used in the industrial practice of transformer diagnostics for the assessment of the mechanical condition of windings and a core. The quality index is based on a numerical comparison of the curve obtained from measurements and the reference curve in a frequency domain. The quality index is based on estimators for the covariance, variance, and expected values. First, both methods of analysis were applied to a group of transformers of similar construction, leading conclusions on quality index values being quickly drawn. Next, it was applied to another transformer’s FRA and VM measurement results. The results showed problems with its mechanical condition, thus confirming that the proposed methods can be used in the practical assessment of transformers with these two diagnostic methods. The assessment of transformer’s active-part mechanical condition with complementary FRA and VM methods can be performed much more easily with the proposed quality indices.

1 January 2010
Verified
Book Chapter
Closed access
PDF file
EKEugeniusz Kornatowski
Eugeniusz Kornatowski