Wojciech Szoka

Mr. Wojciech Szoka

West Pomeranian University of Technology in Szczecin; Poland
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
SBSzymon Banaszak
Szymon Banaszak
Wojciech SzokaWojciech Szoka
Wojciech Szoka
Frequency Response Analysis (FRA) is an important tool used for diagnostic measurements of power transformers. Standard test configuration applied in the industry is the end-to-end open test setup; however, an interwinding capacitive configuration is also used. This paper presents a method—Cross Test Comparison (CTC)—for simultaneous analysis of results coming from both the mentioned test setups. Such an approach could offer a more sensitive tool for detecting some faults; moreover, it takes into consideration the influence of both voltage sides of a transformer in a one test result. The authors have used several indices to quantitatively assess the test results and proposed new approach to data interpretation. CTC method was tested using data from measurements performed in three cases: a unit tested in laboratory with introduced controlled deformations; transformers measured under industrial conditions; and a transformer with FRA changes resulting from tap-changer operations. The results showed that CTC method is more effective at detecting faults on the basis of FRA measurements.

1 April 2018
Verified
Conference Paper
Closed access
SBSzymon Banaszak
Szymon Banaszak
Wojciech SzokaWojciech Szoka
Wojciech Szoka
The paper discusses the problem of tap changer position influence on frequency response of transformer windings. Frequency Response Analysis (FRA) is a standard test used for diagnostics of mechanical condition of transformer's active part. By changing the tap number some part of the regulation winding is added or subtracted from the main winding. This leads to changes in the shape of measured FRA curves. If the test is taken on the other tap than the described one in a report, it may lead to serious misinterpretations. The problem is how to detect such mistake and distinguish it from the influence of real faults, e.g. short circuit or core magnetization. Examples of measurements conducted for various positions of tap changers for several units are given in the paper and criteria allowing to determine if the visible change is the result of wrong tap changer position are described.

11 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
SBSzymon Banaszak
Szymon Banaszak
EKEugeniusz Kornatowski
Eugeniusz Kornatowski
Wojciech SzokaWojciech Szoka
Wojciech Szoka
Frequency response analysis is a method used in transformer diagnostics for the detection of mechanical faults or short-circuits in windings. The interpretation of test results is often performed with the application of numerical indices. However, usually these indices are used for the whole frequency range of the recorded data, returning a single number. Such an approach is inaccurate and may lead to mistakes in the interpretation. An alternative quality assessment is based on the estimation of the local values of the quality index with the moving window method. In this paper, the authors analyse the influence of the width of the input data window for four numerical indices. The analysis is based on the data measured on the transformer with deformations introduced into the winding and also for a 10 MVA transformer measured under industrial conditions. For the first unit the analysis is performed for various window widths and for various extents of the deformation, while in the case of the second the real differences between the frequency response curves are being analysed. On the basis of the results it was found that the choice of the data window width significantly influences the quality of the analysis results and the rules for elements number selection differ for various numerical indices.

1 January 2018 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
JPJerzy Pomianowski
Jerzy Pomianowski
Wojciech SzokaWojciech Szoka
Wojciech Szoka
This paper presents an unusual solution of a vibrating electrometer with synchronous detection for measuring static voltages in the range from 2.5 V to 10 kV or electric fields having intensity from 120 V/m. The input resistance of the instrument is limited only by the leakage of the input electrode. The electrometer constructed by the author also allows identification of the electrical charge sign (a synchronous detector to reduce noise and recover the field sign (positive or negative) without complicated photovoltaic systems that track the phase of the vibrating electrode, e.g. electrometer with field mill type MFM 200A. The instrument is resistant to interference of 50 Hz or higher, so it can be used in industrial conditions. The meter has autonomous power from 6 or 9 V batteries.

1 May 2018
Verified
Conference Paper
Closed access
Wojciech SzokaWojciech Szoka
Wojciech Szoka
SBSzymon Banaszak
Szymon Banaszak
Reliable work of transformers in the power system affects the efficiency of power supplies to consumers. Each transformer should be subjected to periodic diagnostic tests in order to detect damage or prevent the development of defects, which may lead to excluding unit from operation. One of the diagnostic methods of a transformer's active part is Frequency Response Analysis (FRA). Tests carried out using frequency response analysis give a wide range of information about the transformer's technical condition, but the interpretation of the results is very difficult and requires a lot of experience. To facilitate and automate the analysis of measurement results, various types of algorithms for assessment of the transformer's technical condition are developed. The paper presents a comparison of the most frequently used formulas in FRA method, based on data recorded on a test transformer in laboratory conditions using two measuring setups.

5 October 2018 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
Wojciech SzokaWojciech Szoka
Wojciech Szoka
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.