Barbara Postolka

Dr. Barbara Postolka

KU Leuven, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Journal of Biomechanics
Verified
Journal Article
Open access
William R. TaylorWilliam R. Taylor
William R. Taylor
PSPascal Schütz
Pascal Schütz
GBGeorg Bergmann
Georg Bergmann
RLRenate List
Renate List
BPBarbara Postolka
Barbara Postolka
IKInes Kutzner
Ines Kutzner
Combined knowledge of the functional kinematics and kinetics of the human body is critical for understanding a wide range of biomechanical processes including musculoskeletal adaptation, injury mechanics, and orthopaedic treatment outcome, but also for validation of musculoskeletal models. Until now, however, no datasets that include internal loading conditions (kinetics), synchronized with advanced kinematic analyses in multiple subjects have been available. Our goal was to provide such datasets and thereby foster a new understanding of how in vivo knee joint movement and contact forces are interlinked - and thereby impact biomechanical interpretation of any new knee replacement design. In this collaborative study, we have created unique kinematic and kinetic datasets of the lower limb musculoskeletal system for worldwide dissemination by assessing a unique cohort of 6 subjects with instrumented knee implants (Charité - Universitätsmedizin Berlin) synchronized with a moving fluoroscope (ETH Zürich) and other measurement techniques (including whole body kinematics, ground reaction forces, video data, and electromyography data) for multiple complete cycles of 5 activities of daily living. Maximal tibio-femoral joint contact forces during walking (mean peak 2.74 BW), sit-to-stand (2.73 BW), stand-to-sit (2.57 BW), squats (2.64 BW), stair descent (3.38 BW), and ramp descent (3.39 BW) were observed. Internal rotation of the tibia ranged from 3° external to 9.3° internal. The greatest range of anterio-posterior translation was measured during stair descent (medial 9.3 ± 1.0 mm, lateral 7.5 ± 1.6 mm), and the lowest during stand-to-sit (medial 4.5 ± 1.1 mm, lateral 3.7 ± 1.4 mm). The complete and comprehensive datasets will soon be made available online for public use in biomechanical and orthopaedic research and development.

7 August 2019 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PSPascal Schütz
Pascal Schütz
William R. TaylorWilliam R. Taylor
William R. Taylor
BPBarbara Postolka
Barbara Postolka
SFSandro F. Fucentese
Sandro F. Fucentese
PKPeter P. Koch
Peter P. Koch
RLRenate List
Renate List
Joint stability is a primary concern in total knee joint replacement. The GMK Sphere prosthesis was specifically designed to provide medial compartment anterior–posterior (A–P) stability, while permitting rotational freedom of the joint through a flat lateral tibial surface. The objective of this study was to establish the changes in joint kinematics introduced by the GMK Sphere prosthesis during gait activities in comparison to conventional posterior‐stabilized (PS) fixed‐bearing and ultra‐congruent (UC) mobile‐bearing geometries. The A–P translation and internal/external rotation of three cohorts, each with 10 good outcome subjects (2.9 ± 1.6 years postop), with a GMK Sphere, GMK PS or GMK UC implant were analysed throughout complete cycles of gait activities using dynamic videofluoroscopy. The GMK Sphere showed the smallest range of medial compartment A–P translation for level walking, downhill walking, and stair descent (3.6 ± 0.9 mm, 3.1 ± 0.8 mm, 3.9 ± 1.3 mm), followed by the GMK UC (5.7 ± 1.0 mm, 8.0 ± 1.7 mm, 8.7 ± 1.9 mm) and the GMK PS (10.3 ± 2.2 mm, 10.1 ± 2.6 mm, 11.6 ± 1.6 mm) geometries. The GMK Sphere exhibited the largest range of lateral compartment A–P translation (12.1 ± 2.2 mm), and the largest range of tibial internal/external rotation (13.2 ± 2.2°), both during stair descent. This study has shown that the GMK Sphere clearly restricts A–P motion of the medial condyle during gait activities while still allowing a large range of axial rotation. The additional comparison against the conventional GMK PS and UC geometries, not only demonstrates that implant geometry is a key factor in governing tibio‐femoral kinematics, but also that the geometry itself probably plays a more dominant role for joint movement than the type of gait activity. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 37:2337–2347, 2019

9 October 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RLRenate List
Renate List
BPBarbara Postolka
Barbara Postolka
PSPascal Schütz
Pascal Schütz
MHMarco Hitz
Marco Hitz
PSPeter Schwilch
Peter Schwilch
William R. TaylorWilliam R. Taylor
William R. Taylor
Videofluoroscopy has been shown to provide essential information in the evaluation of the functionality of total knee arthroplasties. However, due to the limitation in the field of view, most systems can only assess knee kinematics during highly restricted movements. To avoid the limitations of a static image intensifier, a moving fluoroscope has been presented as a standalone system that allows tracking of the knee during multiple complete cycles of level- and downhill-walking, as well as stair descent, in combination with the synchronous assessment of ground reaction forces and whole body skin marker measurements. Here, we assess the ability of the system to keep the knee in the field of view of the image intensifier. By measuring ten total knee arthroplasty subjects, we demonstrate that it is possible to maintain the knee to within 1.8 ± 1.4 cm vertically and 4.0 ± 2.6 cm horizontally of the centre of the intensifier throughout full cycles of activities of daily living. Since control of the system is based on real-time feedback of a wire sensor, the system is not dependent on repeatable gait patterns, but is rather able to capture pathological motion patterns with low inter-trial repeatability.

6 February 2019 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
PSPascal Schütz
Pascal Schütz
BPBarbara Postolka
Barbara Postolka
HGHans Gerber
Hans Gerber
SFStephen John Ferguson
Stephen John Ferguson
William R. TaylorWilliam R. Taylor
William R. Taylor
RLRenate List
Renate List
Although total knee arthroplasty (TKA) has become a standard surgical procedure for relieving pain, knowledge of the in vivo knee joint kinematics throughout common functional activities of daily living is still missing. The goal of this study was to analyse knee joint motion throughout complete cycles of daily activities in TKA subjects to establish whether a significant difference in joint kinematics occurs between different activities. Using dynamic videofluoroscopy, we assessed tibio-femoral kinematics in six subjects throughout complete cycles of walking, stair descent, sit-to-stand and stand-to-sit. The mean range of condylar anterior–posterior translation exhibited clear task dependency across all subjects. A significantly larger anterior–posterior translation was observed during stair descent compared to level walking and stand-to-sit. Local minima were observed at approximately 30° flexion for different tasks, which were more prominent during loaded task phases. This characteristic is likely to correspond to the specific design of the implant. From the data presented in this study, it is clear that the flexion angle alone cannot fully explain tibio-femoral implant kinematics. As a result, it seems that the assessment of complete cycles of the most frequent functional activities is imperative when evaluating the behaviour of a TKA design in vivo .

12 November 2019 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
Seyyed Hamed Hosseini NasabSeyyed Hamed Hosseini Nasab
Seyyed Hamed Hosseini Nasab
CSColin R. Smith
Colin R. Smith
PSPascal Schütz
Pascal Schütz
BPBarbara Postolka
Barbara Postolka
RLRenate List
Renate List
William R. TaylorWilliam R. Taylor
William R. Taylor
The primary aim of this study was to assess the effects of total knee arthroplasty (TKA) implant design on collateral ligament elongation patterns that occur during level walking, downhill walking, and stair descent. Using a moving fluoroscope, tibiofemoral kinematics were captured in three groups of patients with different TKA implant designs, including posterior stabilized, medial stabilized, and ultra-congruent. The 3D in vivo joint kinematics were then fed into multibody models of the replaced knees and elongation patterns of virtual bundles connecting origin and insertion points of the medial and lateral collateral ligaments (MCL and LCL) were determined throughout complete cycles of all activities. Regardless of the implant design and activity type, non-isometric behavior of the collateral ligaments was observed. The LCL shortened with increasing knee flexion, while the MCL elongation demonstrated regional variability, ranging from lengthening of the anterior bundle to slackening of the posterior bundle. The implant component design did not demonstrate statistically significant effects on the collateral elongation patterns and this was consistent between the studied activities. This study revealed that post-TKA collateral ligament elongation is primarily determined by the knee flexion angle. The different anterior translation and internal rotation that were induced by three distinctive implant designs had minimal impact on the length change patterns of the collateral ligaments.

21 January 2020 in Medical Engineering & Physics
Verified
Journal Article
Open access
BPBarbara Postolka
Barbara Postolka
RLRenate List
Renate List
BTBenedikt Thelen
Benedikt Thelen
PSPascal Schütz
Pascal Schütz
William R. TaylorWilliam R. Taylor
William R. Taylor
Guoyan ZhengGuoyan Zheng
Guoyan Zheng
The accurate quantification of in-vivo tibio-femoral kinematics is essential for understanding joint functionality, but determination of the 3D pose of bones from 2D single-plane fluoroscopic images remains challenging. We aimed to evaluate the accuracy, reliability and repeatability of an intensity-based 2D/3D registration algorithm. The accuracy was evaluated using fluoroscopic images of 2 radiopaque bones in 18 different poses, compared against a gold-standard fiducial calibration device. In addition, 3 natural femora and 3 natural tibiae were used to examine registration reliability and repeatability. Both manual fitting and intensity-based registration exhibited a mean absolute error of <1 mm in-plane. Overall, intensity-based registration of the femoral bone model revealed significantly higher translational and rotational errors than manual fitting, while no statistical differences (except for y-axis translation) were found for the tibial bone model. The repeatability of 108 intensity-based registrations showed mean in-plane standard deviations of 0.23-0.56 mm, but out-of-plane position repeatability was lower (mean SD: femur 7.98 mm, tibia 6.96 mm). SDs for rotations averaged 0.77-2.52°. While the algorithm registered some images extremely well, other images clearly required manual intervention. When the algorithm registered the bones repeatably, it was also accurate, suggesting an approach that includes manual intervention could become practical for efficient and accurate registration.