Although total knee arthroplasty (TKA) has become a standard surgical procedure for relieving pain, knowledge of the in vivo knee joint kinematics throughout common functional activities of daily living is still missing. The goal of this study was to analyse knee joint motion throughout complete cycles of daily activities in TKA subjects to establish whether a significant difference in joint kinematics occurs between different activities. Using dynamic videofluoroscopy, we assessed tibio-femoral kinematics in six subjects throughout complete cycles of walking, stair descent, sit-to-stand and stand-to-sit. The mean range of condylar anterior–posterior translation exhibited clear task dependency across all subjects. A significantly larger anterior–posterior translation was observed during stair descent compared to level walking and stand-to-sit. Local minima were observed at approximately 30° flexion for different tasks, which were more prominent during loaded task phases. This characteristic is likely to correspond to the specific design of the implant. From the data presented in this study, it is clear that the flexion angle alone cannot fully explain tibio-femoral implant kinematics. As a result, it seems that the assessment of complete cycles of the most frequent functional activities is imperative when evaluating the behaviour of a TKA design in vivo .
12 November 2019 in Frontiers in Bioengineering and Biotechnology
The primary aim of this study was to assess the effects of total knee arthroplasty (TKA) implant design on collateral ligament elongation patterns that occur during level walking, downhill walking, and stair descent. Using a moving fluoroscope, tibiofemoral kinematics were captured in three groups of patients with different TKA implant designs, including posterior stabilized, medial stabilized, and ultra-congruent. The 3D in vivo joint kinematics were then fed into multibody models of the replaced knees and elongation patterns of virtual bundles connecting origin and insertion points of the medial and lateral collateral ligaments (MCL and LCL) were determined throughout complete cycles of all activities. Regardless of the implant design and activity type, non-isometric behavior of the collateral ligaments was observed. The LCL shortened with increasing knee flexion, while the MCL elongation demonstrated regional variability, ranging from lengthening of the anterior bundle to slackening of the posterior bundle. The implant component design did not demonstrate statistically significant effects on the collateral elongation patterns and this was consistent between the studied activities. This study revealed that post-TKA collateral ligament elongation is primarily determined by the knee flexion angle. The different anterior translation and internal rotation that were induced by three distinctive implant designs had minimal impact on the length change patterns of the collateral ligaments.
The accurate quantification of in-vivo tibio-femoral kinematics is essential for understanding joint functionality, but determination of the 3D pose of bones from 2D single-plane fluoroscopic images remains challenging. We aimed to evaluate the accuracy, reliability and repeatability of an intensity-based 2D/3D registration algorithm. The accuracy was evaluated using fluoroscopic images of 2 radiopaque bones in 18 different poses, compared against a gold-standard fiducial calibration device. In addition, 3 natural femora and 3 natural tibiae were used to examine registration reliability and repeatability. Both manual fitting and intensity-based registration exhibited a mean absolute error of <1 mm in-plane. Overall, intensity-based registration of the femoral bone model revealed significantly higher translational and rotational errors than manual fitting, while no statistical differences (except for y-axis translation) were found for the tibial bone model. The repeatability of 108 intensity-based registrations showed mean in-plane standard deviations of 0.23-0.56 mm, but out-of-plane position repeatability was lower (mean SD: femur 7.98 mm, tibia 6.96 mm). SDs for rotations averaged 0.77-2.52°. While the algorithm registered some images extremely well, other images clearly required manual intervention. When the algorithm registered the bones repeatably, it was also accurate, suggesting an approach that includes manual intervention could become practical for efficient and accurate registration.
This research assessed the influence of various heel elevation conditions on spinal kinematic and kinetic data during loaded (25% and 50% of body weight) high-bar back squats. Ten novice (mass 67.6 ± 12.4 kg, height 1.73 ± 0.10 m) and ten regular weight trainers (mass 66.0 ± 10.7 kg, height 1.71 ± 0.09 m) completed eight repetitions at each load wearing conventional training shoes standing on the flat level floor (LF) and on an inclined board (EH). The regular weight training group performed an additional eight repetitions wearing weightlifting shoes (WS). Statistical parametric mapping (SPM1D) and repeated measures analysis of variance were used to assess differences in spinal curvature and kinetics across the shoe/floor conditions and loads. SPM1D analyses indicated that during the LF condition the novice weight trainers had greater moments around L4/L5 than the regular weight trainers during the last 20% of the lift (P < 0.05), with this difference becoming non-significant during the EH condition. This study indicates that from a perspective of spinal safety, it appears advantageous for novice weight trainers to perform back squats with their heels slightly elevated, while regular weight trainers appear to realize only limited benefits performing back squats with either EH or WS.
12 April 2021 in Journal of Bone and Joint Surgery
Background: Improved knowledge of in vivo function of the collateral ligaments is essential for enhancing rehabilitation and guiding surgical reconstruction as well as soft-tissue balancing in total knee arthroplasty. The aim of this study was to quantify in vivo elongation patterns of the collateral ligaments throughout complete cycles of functional activities. Methods: Knee kinematics were measured using radiographic images captured with a mobile fluoroscope while healthy subjects performed level walking, downhill walking, and stair descent. The registered in vivo tibiofemoral kinematics were then used to drive subject-specific multibody knee models to track collateral ligament elongation. Results: The elongation patterns of the medial collateral ligament varied distinctly among its bundles, ranging from lengthening of the anterior fibers to shortening of the posterior bundle with increases in the knee flexion angle. The elongation patterns of the lateral collateral ligament varied considerably among subjects. It showed an average 4% shortening with increasing flexion until 60% to 70% of the gait cycle, and then recovered during the terminal-swing phase until reaching its reference length (defined at heel strike). Conclusions: The observed nonuniform elongation of the medial collateral ligament bundles suggests that single-bundle reconstruction techniques may not fully restore healthy ligament function. Moreover, the observed ligament elongation patterns indicate greater varus than valgus laxity in the loaded knee. Clinical Relevance: Through providing key knowledge about the in vivo elongation patterns of the collateral ligaments throughout complete cycles of functional activities, this study offers in vivo evidence for benchmarking ligament reconstruction and soft-tissue balancing in total knee arthroplasty.