arianna elefante

Dr. arianna elefante


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AEarianna elefante
arianna elefante
GMGiansergio Menduni
Giansergio Menduni
HRHubert Rossmadl
Hubert Rossmadl
VMVerena Mackowiak
Verena Mackowiak
Marilena GiglioMarilena Giglio
Marilena Giglio
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
A dual-gas sensor based on the combination of a quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor and an electronic hygrometer was realized for the simultaneous detection of methane (CH4) and water vapor (H2O) in air. The QEPAS sensor employed an interband cascade laser operating at 3.34 μm capable of targeting a CH4 absorption line at 2988.8 cm−1 and a water line at 2988.6 cm−1. Water vapor was measured with both the electronic hygrometer and the QEPAS sensor for comparison. The measurement accuracy provided by the hygrometer enabled the adjustment of methane QEPAS signal with respect to the water vapor concentration to retrieve the actual CH4 concentration. The sensor was tested by performing prolonged measurements of CH4 and H2O over 60 h to demonstrate the effectiveness of this approach for environmental monitoring applications.

24 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GMGiansergio Menduni
Giansergio Menduni
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
Marilena GiglioMarilena Giglio
Marilena Giglio
SRStefano Dello Russo
Stefano Dello Russo
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
A study of the front-end electronics for quartz tuning forks (QTFs) employed as optoacoustic transducers in quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing is reported. Voltage amplifier-based electronics is proposed as an alternative to the transimpedance amplifier commonly employed in QEPAS experiments. The possibility to use differential input/output configurations with respect to a single-ended configuration has also been investigated. Four different architectures have been realized and tested: a single-ended transimpedance amplifier, a differential output transimpedance amplifier, a differential input voltage amplifier and a fully differential voltage amplifier. All of these amplifiers were implemented in a QEPAS sensor operating in the mid-IR spectral range. Water vapor in ambient air has been selected as the target gas species for the amplifiers testing and validation. The signal-to-noise ratio (SNR) measured for the different configurations has been used to compare the performances of the proposed architectures. We demonstrated that the fully differential voltage amplifier allows for a nearly doubled SNR with respect to the typically used single-ended transimpedance amplifier.