Stefano Dello Russo

Dr. Stefano Dello Russo


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2021 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
TWTingting Wei
Tingting Wei
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
SRStefano Dello Russo
Stefano Dello Russo
HWHongpeng Wu
Hongpeng Wu
GMGiansergio Menduni
Giansergio Menduni
Lei DongLei Dong
Lei Dong
Infrared laser technology over the last decades has led to an increasing demand for optical detectors with high sensitivity and a wide operative spectral range suitable for spectroscopic applications. In this work, we report on the performance of a custom quartz tuning fork used as a sensitive and broadband infrared photodetector for absorption spectroscopy. The photodetection process is based on light impacting on the tuning fork and creating a local temperature increase that generates a strain field. This light-induced, thermoelastic conversion produces an electrical signal proportional to the absorbed light intensity due to quartz piezoelectricity. A finite-element-method analysis was used to relate the energy release with the induced thermal distribution. To efficiently exploit the photo-induced thermoelastic effects in the low-absorbance spectral region of quartz also, chromium/gold layers, acting as opaque surface, have been deposited on the quartz surface. To demonstrate the flat response as photodetectors, a custom tuning fork, having a fundamental resonance frequency of 9.78 kHz and quality factor of 11 500 at atmospheric pressure, was employed as photodetector in a tunable diode laser absorption spectroscopy setup and tested with five different lasers with emission wavelength in the 1.65–10.34 μm range. A spectrally flat responsivity of ∼2.2 kV/W was demonstrated, corresponding to a noise-equivalent power of 1.5 nW/√Hz, without employing any thermoelectrical cooling systems. Finally, a heterodyne detection scheme was implemented in the tunable diode laser absorption spectroscopy setup to retrieve the resonance properties of the quartz tuning fork together with the gas concentration in a single, fast measurement.

16 January 2019 in Optics Express
Verified
Journal Article
Open access
PDF file
PPPietro Patimisco
Pietro Patimisco
ASAngelo Sampaolo
Angelo Sampaolo
Marilena GiglioMarilena Giglio
Marilena Giglio
SRStefano Dello Russo
Stefano Dello Russo
VMVerena Mackowiak
Verena Mackowiak
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
We report on the design, realization, and performance of novel quartz tuning forks (QTFs) optimized for quartz-enhanced photoacoustic spectroscopy (QEPAS). Starting from a QTF geometry designed to provide a fundamental flexural in-plane vibrational mode resonance frequency of ~16 kHz, with a quality factor of 15,000 at atmospheric pressure, two novel geometries have been realized: a QTF with T-shaped prongs and a QTF with prongs having rectangular grooves carved on both surface sides. The QTF with grooves showed the lowest electrical resistance, while the T-shaped prongs QTF provided the best photoacoustic response in terms of signal-to-noise ratio (SNR). When acoustically coupled with a pair of micro-resonator tubes, the T-shaped QTF provides a SNR enhancement of a factor of 60 with respect to the bare QTF, which represents a record value for mid-infrared QEPAS sensing.

23 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SRStefano Dello Russo
Stefano Dello Russo
Marilena GiglioMarilena Giglio
Marilena Giglio
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
GMGiansergio Menduni
Giansergio Menduni
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
A theoretical model describing the acoustic coupling between two resonator tubes in spectrophones exploiting custom-made quartz tuning forks (QTFs) is proposed. The model is based on an open-end correction to predict the optimal tube length. A calculation of the sound field distribution from one tube exit allowed for the estimation of the optimal radius as a function of the QTF prong spacing and the sound wavelength. The theoretical predictions have been confirmed using experimental studies employing a custom QTF with a fundamental flexural mode resonance frequency of 15.8 kHz and a quality factor of 15,000 at atmospheric pressure. The spacing between the two prongs was 1.5 mm. Spectrophones mounting this QTF were implemented for the quartz-enhanced photoacoustic detection of water vapor in air in the mid-infrared spectral range.

28 November 2020 in Molecules
Verified
Journal Article
Open access
PDF file
GMGiansergio Menduni
Giansergio Menduni
FSFabrizio Sgobba
Fabrizio Sgobba
SRStefano Dello Russo
Stefano Dello Russo
ARAda Cristina Ranieri
Ada Cristina Ranieri
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
We report on a fiber-coupled, quartz-enhanced photoacoustic spectroscopy (QEPAS) near-IR sensor for sequential detection of methane (CH4 or C1) and ethane (C2H6 or C2) in air. With the aim of developing a lightweight, compact, low-power-consumption sensor suitable for unmanned aerial vehicles (UAVs)-empowered environmental monitoring, an all-fiber configuration was designed and realized. Two laser diodes emitting at 1653.7 nm and 1684 nm for CH4 and C2H6 detection, respectively, were fiber-combined and fiber-coupled to the collimator port of the acoustic detection module. No cross talk between methane and ethane QEPAS signal was observed, and the related peak signals were well resolved. The QEPAS sensor was calibrated using gas samples generated from certified concentrations of 1% CH4 in N2 and 1% C2H6 in N2. At a lock-in integration time of 100 ms, minimum detection limits of 0.76 ppm and 34 ppm for methane and ethane were achieved, respectively. The relaxation rate of CH4 in standard air has been investigated considering the effects of H2O, N2 and O2 molecules. No influence on the CH4 QEPAS signal is expected when the water vapor concentration level present in air varies in the range 0.6–3%.

24 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GMGiansergio Menduni
Giansergio Menduni
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
Marilena GiglioMarilena Giglio
Marilena Giglio
SRStefano Dello Russo
Stefano Dello Russo
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
A study of the front-end electronics for quartz tuning forks (QTFs) employed as optoacoustic transducers in quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing is reported. Voltage amplifier-based electronics is proposed as an alternative to the transimpedance amplifier commonly employed in QEPAS experiments. The possibility to use differential input/output configurations with respect to a single-ended configuration has also been investigated. Four different architectures have been realized and tested: a single-ended transimpedance amplifier, a differential output transimpedance amplifier, a differential input voltage amplifier and a fully differential voltage amplifier. All of these amplifiers were implemented in a QEPAS sensor operating in the mid-IR spectral range. Water vapor in ambient air has been selected as the target gas species for the amplifiers testing and validation. The signal-to-noise ratio (SNR) measured for the different configurations has been used to compare the performances of the proposed architectures. We demonstrated that the fully differential voltage amplifier allows for a nearly doubled SNR with respect to the typically used single-ended transimpedance amplifier.

3 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FSFabrizio Sgobba
Fabrizio Sgobba
GMGiansergio Menduni
Giansergio Menduni
SRStefano Dello Russo
Stefano Dello Russo
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
In this paper the performances of two spectrophones for quartz-enhanced photoacoustic spectroscopy (QEPAS)-based ethane gas sensing were tested and compared. Each spectrophone contains a quartz tuning fork (QTF) acoustically coupled with a pair of micro-resonator tubes and having a fundamental mode resonance frequency of 32.7 kHz (standard QTF) and 12.4 kHz (custom QTF), respectively. The spectrophones were implemented into a QEPAS acoustic detection module (ADM) together with a preamplifier having a gain bandwidth optimized for the respective QTF resonance frequency. Each ADM was tested for ethane QEPAS sensing, employing a custom pigtailed laser diode emitting at ~1684 nm as the exciting light source. By flowing 1% ethane at atmospheric pressure, a signal-to-noise ratio of 453.2 was measured by implementing the 12.4 kHz QTF-based ADM, ~3.3 times greater than the value obtained using a standard QTF. The minimum ethane concentration detectable using a 100 ms lock-in integration time achieving the 12.4 kHz custom QTF was 22 ppm.