Anna Porfireva

Dr. Anna Porfireva

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
GEGennady Evtugyn
Gennady Evtugyn
APAnna Porfireva
Anna Porfireva
RSRezeda Shamagsumova
Rezeda Shamagsumova
Tibor HianikTibor Hianik
Tibor Hianik
Carbon nanomaterials offer unique opportunities for the assembling of electrochemical aptasensors due to their high electroconductivity, redox activity, compatibility with biochemical receptors and broad possibilities of functionalization and combination with other auxiliary reagents. In this review, the progress in the development of electrochemical aptasensors based on carbon nanomaterials in 2016–2020 is considered with particular emphasis on the role of carbon materials in aptamer immobilization and signal generation. The synthesis and properties of carbon nanotubes, graphene materials, carbon nitride, carbon black particles and fullerene are described and their implementation in the electrochemical biosensors are summarized. Examples of electrochemical aptasensors are classified in accordance with the content of the surface layer and signal measurement mode. In conclusion, the drawbacks and future prospects of carbon nanomaterials’ application in electrochemical aptasensors are briefly discussed.

26 November 2013 in Sensors
Verified
Journal Article
Open access
PDF file
GEGennady Evtugyn
Gennady Evtugyn
APAnna Porfireva
Anna Porfireva
VSVeronika Stepanova
Veronika Stepanova
Marianna P. KutyrevaMarianna P. Kutyreva
Marianna P. Kutyreva
AGAlfiya Gataulina
Alfiya Gataulina
Tibor HianikTibor Hianik
Tibor Hianik
An impedimetric aptasensor for ochratoxin A (OTA) detection has been developed on the base of a gold electrode covered with a new modifier consisting of electropolymerized Neutral Red and a mixture of Au nanoparticles suspended in the dendrimeric polymer Botlorn H30®. Thiolated aptamer specific to OTA was covalently attached to Au nanoparticles via Au-S bonding. The interaction of the aptamer with OTA induced the conformational switch of the aptamer from linear to guanine quadruplex form followed by consolidation of the surface layer and an increase of the charge transfer resistance. The aptasensor makes it possible to detect from 0.1 to 100 nM of OTA (limit of detection: 0.02 nM) in the presence of at least 50 fold excess of ochratoxin B. The applicability of the aptasensor for real sample assay was confirmed by testing spiked beer samples. The recovery of 2 nM OTA was found to be 70% for light beer and 78% for dark beer.

12 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
GEGennady Evtugyn
Gennady Evtugyn
APAnna Porfireva
Anna Porfireva
George TsekenisGeorge Tsekenis
George Tsekenis
VOVeronika Oravczová
Veronika Oravczová
Tibor HianikTibor Hianik
Tibor Hianik
Antibiotics are often used in human and veterinary medicine for the treatment of bacterial diseases. However, extensive use of antibiotics in agriculture can result in the contamination of common food staples such as milk. Consumption of contaminated products can cause serious illness and a rise in antibiotic resistance. Conventional methods of antibiotics detection such are microbiological assays chromatographic and mass spectroscopy methods are sensitive; however, they require qualified personnel, expensive instruments, and sample pretreatment. Biosensor technology can overcome these drawbacks. This review is focused on the recent achievements in the electrochemical biosensors based on nucleic acid aptamers for antibiotic detection. A brief explanation of conventional methods of antibiotic detection is also provided. The methods of the aptamer selection are explained, together with the approach used for the improvement of aptamer affinity by post-SELEX modification and computer modeling. The substantial focus of this review is on the explanation of the principles of the electrochemical detection of antibiotics by aptasensors and on recent achievements in the development of electrochemical aptasensors. The current trends and problems in practical applications of aptasensors are also discussed.

16 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
YKYurii Kuzin
Yurii Kuzin
DKDominika Kappo
Dominika Kappo
APAnna Porfireva
Anna Porfireva
Dmitriy ShurpikDmitriy Shurpik
Dmitriy Shurpik
Ivan StoikovIvan Stoikov
Ivan Stoikov
Tibor HianikTibor Hianik
Tibor Hianik
Voltammetric DNA sensor has been proposed on the platform of glassy carbon electrode covered with carbon black with adsorbed pillar[5]arene molecules. Electropolymerization of Neutral Red performed in the presence of native or oxidatively damaged DNA resulted in formation of hybrid material which activity depended on the DNA conditions. The assembling of the surface layer was confirmed by scanning electron microscopy and electrochemical impedance spectroscopy. The influence of DNA and pillar[5]arene on redox activity of polymeric dye was investigated and a significant increase of the peak currents was found for DNA damaged by reactive oxygen species generated by Cu2+/H2O2 mixture. Pillar[5]arene improves the electron exchange conditions and increases the response and its reproducibility. The applicability of the DNA sensor developed was shown on the example of ascorbic acid as antioxidant. It decreases the current in the concentration range from 1.0 μM to 1.0 mM. The possibility to detect antioxidant activity was qualitatively confirmed by testing tera infusion. The DNA sensor developed can find application in testing of carcinogenic species and searching for new antitumor drugs.

5 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
GEGennady Evtugyn
Gennady Evtugyn
SBSvetlana Belyakova
Svetlana Belyakova
APAnna Porfireva
Anna Porfireva
Tibor HianikTibor Hianik
Tibor Hianik
Metal-organic frameworks (MOFs) offer a unique variety of properties and morphology of the structure that make it possible to extend the performance of existing and design new electrochemical biosensors. High porosity, variable size and morphology, compatibility with common components of electrochemical sensors, and easy combination with bioreceptors make MOFs very attractive for application in the assembly of electrochemical aptasensors. In this review, the progress in the synthesis and application of the MOFs in electrochemical aptasensors are considered with an emphasis on the role of the MOF materials in aptamer immobilization and signal generation. The literature information of the use of MOFs in electrochemical aptasensors is classified in accordance with the nature and role of MOFs and a signal mode. In conclusion, future trends in the application of MOFs in electrochemical aptasensors are briefly discussed.

24 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
TKTatiana Kulikova
Tatiana Kulikova
APAnna Porfireva
Anna Porfireva
GEGennady Evtugyn
Gennady Evtugyn
Tibor HianikTibor Hianik
Tibor Hianik
A DNA sensor has been proposed on the platform of glassy carbon electrode modified with native DNA implemented between two electropolymerized layers of polyaniline. The surface layer was assembled by consecutive stages of potentiodynamic electrolysis, DNA drop casting, and second electrolysis, which was required for capsulation of the DNA molecules and prevented their leaching into the solution. Surface layer assembling was controlled by cyclic voltammetry, electrochemical impedance spectroscopy, atomic force, and scanning electron microscopy. For doxorubicin measurement, the DNA sensor was first incubated in the Methylene blue solution that amplified signal due to DNA intercalation and competition with the doxorubicin molecules for the DNA binding sites. The charge transfer resistance of the inner layer interface decreased with the doxorubicin concentration in the range from 1.0 pM to 0.1 μM (LOD 0.6 pM). The DNA sensor was tested for the analysis of spiked artificial urine samples and showed satisfactory recovery in concentration range of 0.05–10 μM. The DNA sensor developed can find application in testing of antitumor drugs and some other DNA damaging factors.