Demand is soaring for data centers with advanced data-processing capabilities. In data centers with high-temperature information technology (IT) equipment, enormous cooling systems are operated year-round. To date, studies have aimed to improve the cooling efficiency of server-room units, but cooling-energy-consumption analysis considering the recirculation of exhaust air (EA) has not been researched to a sufficient degree. This study analyzed the cooling-energy saving effects considering the EA-recirculation and supply-air (SA)-temperature conditions when direct and indirect air-side economizers were applied to a data center in Korea. Thirteen case studies were conducted. The results showed that when the EA-recirculation ratio in the direct air-side economizer was 15%, its annual cooling-energy consumption increased by approximately 6.1% compared to the case with no recirculation. The indirect air-side economizer also exhibited an approximately 9% increase in cooling-energy consumption. On the other hand, when the SA temperature changed to 22 °C, the annual cooling-energy consumption of the direct and indirect air-side economizers decreased by approximately 67% and 55%, respectively, compared to a central chilled-water system. This indicates the importance of developing measures to prevent EA recirculation and of securing a wind path for the improvement of air-conditioning efficiency in data centers at the design stage.
Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However, earlier studies have not evaluated an operating method of air purifiers considering the inflow of fine particulate matter into the body or reduction performance of the concentration of fine particulate matter. There is a limit to controlling the concentration of fine particulate matter of the overall space where an air purifier is fixed in one spot as the source of indoor fine particulate matter is varied. Accordingly, this study analyzed changes in the concentration of indoor fine particulate matter through an experiment according to the discharging method and location of a fixed air purifier considering the inflow route of fine particulate matter into the body and their harmfulness. The study evaluated the purifiers’ performance in reducing the concentration of fine particulate matter in the occupants’ breathing zone according to the operation method in which a movable air purifier responds to the movement of occupants. The results showed the concentration of fine particulate matter around the breathing zone of the occupants had decreased by about 51 μg/m3 compared to the surrounding concentration in terms of the operating method in which an air purifier tracks occupants in real-time, and a decrease of about 68 μg/m3 in terms of the operating method in which an air purifier controls the zone. On the other hand, a real-time occupant tracking method may face a threshold due to the moving path of an air purifier and changes in the number of occupants. A zone controlling method is deemed suitable as an operating method of a movable air purifier to reduce the concentration of fine particulate matter in the breathing zone of occupants.
In recent years, there has been an increase in the consumption of energy for lighting purposes, which has led to an increase in the number of studies being conducted on this subject. Most studies have focused on light shelves, which are daylighting systems used for reducing the lighting energy required for the interiors of buildings. However, the existing light shelves cannot actively deal with external environmental factors, which often lead to an infringement of the right to light during the night when the performance of the light shelf deteriorates. Therefore, in this study, we propose a light shelf with a width‐adjustable reflector and verify its validity using a testbed. The reflector of the proposed light shelf system is modularized so that the length can be adjusted in stages. The optimum width of the light shelf is calculated in terms of the energy reduction and uniformity ratio improvement, and the obtained optimum width is varied depending on the season. We find that the width‐adjustable reflector can save 20% and 21.6% more lighting energy than light shelves with fixed reflector widths of 0.3 m and 0.6 m, respectively.
With the industrialization and rapid development of technology that can measure the concentration of pollutants, studies on indoor atmosphere assessment focusing on occupants have been recently conducted. Pollutants that worsen indoor atmosphere include gaseous and particulate matter (PM), and the effects and diffusion characteristics that influence indoor atmosphere vary depending on the indoor and outdoor concentration. White dust is a PM generated from minerals in water used for humidifiers during winter. Therefore, studies on the impact of white dust on human health and its size distribution are being actively conducted. However, since the indoor PM concentration varies depending on the humidification method and water type used, relevant studies are needed. Accordingly, this study examined the change in the PM2.5 concentration and relative humidity on the basis of water types and humidification method. It was found that the indoor PM2.5 concentration varied from 16 to 350 ug/m3, depending on the water types used for an ultrasonic humidifier. Conversely, when using a natural evaporative humidifier, white dust did not increase the indoor PM2.5 concentration, regardless of the mineral content of the water used. Considering both humidification ability and continuous humidifier use indoors, water purifier with nano-trap filters must be utilized for ultrasonic humidifiers.
10 July 2013 in Korean Journal of Air-Conditioning and Refrigeration Engineering
Improved quality of life has led to a growing demand for better indoor air quality (IAQ). Buildings are becoming more airtight and insulated in order to minimize energy consumption. The importance of both energy conservation and IAQ improvement has been recognized and addressed by many studies. Bake-out is the process of using indoor heating to remove volatile compounds present in building materials and furnishings so that they can be vented out into the atmosphere. Indiscriminate use of heating to increase the surface temperature of materials during this process can result in significant loss of energy. Therefore, energy-efficient bake-out should be performed by considering both the floor temperature and the emission amount of pollutants. This study aims to investigate an effective and economical bake-out implementation strategy via experimentation and computational fluid dynamics analysis. The results showed weak direct correlation between the heating energy consumption and the amount of pollutants emitted. The study also highlights the passive option of installing sorptive building materials for improving IAQ economically.