Héctor García-Martínez

Prof. Héctor García-Martínez

Miguel Hernandez University, Elche, Spain
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Carlos G. JuanCarlos G. Juan
Carlos G. Juan
Benjamin PotelonBenjamin Potelon
Benjamin Potelon
CQCédric Quendo
Cédric Quendo
Héctor García-MartínezHéctor García-Martínez
Héctor García-Martínez
Ernesto ÁvilaErnesto Ávila
Ernesto Ávila
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
A low-cost, additively manufactured, biocompatible glucose sensor based on the changes in the unloaded quality factor ( $Q_{\mathbf {u}}$ ) with a single split-ring resonator is presented. An exposition of the fundamentals for the use of the $Q_{\mathbf {u}}$ as sensing parameter with microwave planar resonant sensors is shown. The convenience of this sensing parameter is analyzed from the theoretical point of view, and practical design and optimization guidelines are inferred with a special focus on the optimization of $Q_{\mathbf {u}}$ sensitivity to glucose concentration. For practical demonstration and experimental assessment, a novel inverted microstrip configuration is considered, built upon a customized structure made with a certified biocompatible material thanks to 3-D printing techniques, which is aimed to provide for a stronger interaction between the electromagnetic fields and the sample. Two metallization solutions are investigated, yielding devices operating at 4.50 and 4.62 GHz, with operating $Q_{\mathbf {u}}$ of 16.36 and 22.00, relative $Q_{\mathbf {u}}$ sensitivities of 1.377 and 2.727, $Q_{\mathbf {u}}$ sensitivities to glucose content within the physiological range of $0.3\times 10^{-3}$ per mg/dL and $0.6\times 10^{-3}$ per mg/dL, sensing areas of approximately $11.7\times8.8$ mm 2 and total structure sizes of 950.0 $\times 35.0\times3.5$ mm 3 . The devices show good performance with water–glucose solutions covering a wide range of concentrations, involving physiological as well as industry-related ones.

27 January 2021 in Electronics
Verified
Journal Article
Open access
PDF file
AMAndrea Martínez-Lozano
Andrea Martínez-Lozano
CBCarolina Blanco-Angulo
Carolina Blanco-Angulo
Héctor García-MartínezHéctor García-Martínez
Héctor García-Martínez
Roberto GutiérrezRoberto Gutiérrez
Roberto Gutiérrez
GTGermán Torregrosa-Penalva
Germán Torregrosa-Penalva
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
This paper presents the design of a printed step-type monopole antenna for biological tissue analysis and medical imaging applications in the microwave frequency range. The design starts from a very simple and widely known rectangular monopole antenna, and different modifications to the antenna geometry are made in order to increase the bandwidth. The antenna dimensions are optimized by means of a parametric analysis of each dimension using a 3-D electromagnetic simulator based on the finite element method. The optimized antenna, with final dimensions of 40 × 36 mm2, is manufactured onto a low-cost FR4 (fiber glass epoxy) substrate. The characteristics of the antenna have been measured inside an anechoic chamber, obtaining an omnidirectional radiation pattern and a working frequency range between 2.7 GHz and 11.4 GHz, which covers the UWB frequencies and enables the use of the antenna in medical imaging applications. Finally, the behaviour of four of these antennas located around a realistic breast model, made with biocompatible materials, has been analysed with the electromagnetic simulator, obtaining good results and demonstrating the usefulness of the designed antenna in the proposed application.

31 August 2019 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
Carlos G. JuanCarlos G. Juan
Carlos G. Juan
Héctor García-MartínezHéctor García-Martínez
Héctor García-Martínez
Ernesto ÁvilaErnesto Ávila
Ernesto Ávila
EBEnrique Bronchalo
Enrique Bronchalo
Vicente GalianoVicente Galiano
Vicente Galiano
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro

12 September 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
CBCarolina Blanco-Angulo
Carolina Blanco-Angulo
AMAndrea Martínez-Lozano
Andrea Martínez-Lozano
Roberto GutiérrezRoberto Gutiérrez
Roberto Gutiérrez
Carlos G. JuanCarlos G. Juan
Carlos G. Juan
Héctor García-MartínezHéctor García-Martínez
Héctor García-Martínez
Ernesto ÁvilaErnesto Ávila
Ernesto Ávila
This work introduces a microwave-based system able to detect tumours in breast phantoms in a non-invasive way. The data acquisition system is composed of a hardware system which involves high-frequency components (antennas, switches and cables), a microcontroller, a vector network analyser used as measurement instrument and a computer devoted to the control and automation of the operation of the system. Concerning the software system, the computer runs a Python script which is in charge of mastering and automatising all the required stages for the data acquisition, from initialisation of the hardware system to performing and saving the measurements. We also report on the design of the high-performance broadband antenna used to carry out the measurements, as well as on the algorithm employed to build the final medical images, based on an adapted version of the so-called Improved Delay-and-Sum (IDAS) algorithm improved by a Hamming window filter and averaging preprocessing. The calibration and start-up of the system are also described. The experimental validation includes the use of different tumour models with different dielectric properties inside the breast phantom. The results show promising tumour detection capabilities, even when there is low dielectric contrast between the tumoural and healthy tissues, as is the usual case for dense breasts in young women.

28 August 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Héctor García-MartínezHéctor García-Martínez
Héctor García-Martínez
Ernesto ÁvilaErnesto Ávila
Ernesto Ávila
GTGermán Torregrosa-Penalva
Germán Torregrosa-Penalva
ARAlberto Rodríguez-Martínez
Alberto Rodríguez-Martínez
CBCarolina Blanco-Angulo
Carolina Blanco-Angulo
MLMiguel Ángel de la Casa Lillo
Miguel Ángel de la Casa Lillo
This work presents a study on the implementation and manufacturing of low-cost microwave electronic circuits, made with additive manufacturing techniques using fused deposition modeling (FDM) technology. First, the manufacturing process of substrates with different filaments, using various options offered by additive techniques in the manufacture of 3D printing parts, is described. The implemented substrates are structurally analyzed by ultrasound techniques to verify the correct metallization and fabrication of the substrate, and the characterization of the electrical properties in the microwave frequency range of each filament is performed. Finally, standard and novel microwave filters in microstrip and stripline technology are implemented, making use of the possibilities offered by additive techniques in the manufacturing process. The designed devices were manufactured and measured with good results, which demonstrates the possibility of using low-cost 3D printers in the design process of planar microwave circuits.

15 July 2020 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
Héctor García-MartínezHéctor García-Martínez
Héctor García-Martínez
Ernesto ÁvilaErnesto Ávila
Ernesto Ávila
GTGermán Torregrosa-Penalva
Germán Torregrosa-Penalva
NDNicolo Delmonte
Nicolo Delmonte
LSLorenzo Silvestri
Lorenzo Silvestri
Maurizio BozziMaurizio Bozzi
Maurizio Bozzi
A novel band-pass filter topology in waveguide technology is presented in this work. The proposed filter design is based on a periodic structure that uses modified sections of a single-ridge waveguide (SRW) as the unit cell to produce the desired frequency response. Two-step height profiles are included in the central part of the SRW, which provide useful parameters to yield a simple design method to achieve the required filtering characteristics. The suggested topology and design process are used to achieve band-pass filter responses with different fractional bandwidth and rejection characteristics. A 54% fractional bandwidth band-pass filter centered at 5.4 GHz is implemented using low cost 3-D additive manufacturing techniques, which allow fast prototyping and the fabrication of complex geometries. Experimental measurements are in agreement with the expected simulated response of the designed band-pass filter.