Roberto Gutiérrez

Dr. Roberto Gutiérrez

Industrial Electronics research group, Miguel Hernandez University of Elche, 03202 Elche, Spain
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2013 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Jose BlanesJose Blanes
Jose Blanes
Roberto GutiérrezRoberto Gutiérrez
Roberto Gutiérrez
Ausias GarrigosAusias Garrigos
Ausias Garrigos
JLJosé Luís Lizán
José Luís Lizán
JCJesús Martínez Cuadrado
Jesús Martínez Cuadrado
This paper describes the implementation of a hybrid energy storage system (HESS) using ultracapacitors (UCs) to protect the batteries of an electrical vehicle (EV) from high-peak currents and therefore extend their lifetime. A field-programmable gate array (FPGA) controlled interleaved bidirectional buck-boost converter working in a discontinuous conduction mode, has been designed to transfer the energy between the batteries and the UCs. The FPGA is responsible of generating all the converter gate signals and implements the control stage needed to smooth the battery current peaks. The control strategy is based on dividing the current demand of the motor into two parts (high-frequency current and low-frequency current), the batteries supply the low frequency part and the UCs supply the high-frequency part. Experimental tests have been carried out driving the EV under different scenarios. Experimental results demonstrate the good behavior of the proposed HESS, although the potential battery life extension is still under quantification. The consumption of the EV has been increased due to the converter losses, this increase is minimum under typical driving scenarios, but is quite important in start-stop driving cycles.

14 January 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DMDavid Marroqui
David Marroqui
Jose BlanesJose Blanes
Jose Blanes
Ausias GarrigosAusias Garrigos
Ausias Garrigos
Roberto GutiérrezRoberto Gutiérrez
Roberto Gutiérrez
This article presents a new ultrafast DC Solid State Circuit Breaker (SSCB) that uses a Silicon Carbide (SiC) cascode as the main switching and limiting semiconductor and an isolated photovoltaic driver to control it. The proposed topology is self-powered and fully implemented with discrete parts.

25 October 2010 in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
Verified
Journal Article
Closed access
Roberto GutiérrezRoberto Gutiérrez
Roberto Gutiérrez
JVJavier Valls
Javier Valls
A low cost, high-speed architecture for the computation of the binary logarithm is proposed. It is based on the Mitchell approximation with two correction stages: a piecewise linear interpolation with power-of-two slopes and truncated mantissa, and a LUT-based correction stage that correct the piecewise interpolation error. The architecture has been implemented in an FPGA device and the results are compared with other low cost architectures requiring less area and achieving high-speed.

1 December 2014 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
Ausias GarrigosAusias Garrigos
Ausias Garrigos
JLJ.L. Lizán
J.L. Lizán
Jose BlanesJose Blanes
Jose Blanes
Roberto GutiérrezRoberto Gutiérrez
Roberto Gutiérrez

27 January 2021 in Electronics
Verified
Journal Article
Open access
PDF file
AMAndrea Martínez-Lozano
Andrea Martínez-Lozano
CBCarolina Blanco-Angulo
Carolina Blanco-Angulo
Héctor García-MartínezHéctor García-Martínez
Héctor García-Martínez
Roberto GutiérrezRoberto Gutiérrez
Roberto Gutiérrez
GTGermán Torregrosa-Penalva
Germán Torregrosa-Penalva
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
This paper presents the design of a printed step-type monopole antenna for biological tissue analysis and medical imaging applications in the microwave frequency range. The design starts from a very simple and widely known rectangular monopole antenna, and different modifications to the antenna geometry are made in order to increase the bandwidth. The antenna dimensions are optimized by means of a parametric analysis of each dimension using a 3-D electromagnetic simulator based on the finite element method. The optimized antenna, with final dimensions of 40 × 36 mm2, is manufactured onto a low-cost FR4 (fiber glass epoxy) substrate. The characteristics of the antenna have been measured inside an anechoic chamber, obtaining an omnidirectional radiation pattern and a working frequency range between 2.7 GHz and 11.4 GHz, which covers the UWB frequencies and enables the use of the antenna in medical imaging applications. Finally, the behaviour of four of these antennas located around a realistic breast model, made with biocompatible materials, has been analysed with the electromagnetic simulator, obtaining good results and demonstrating the usefulness of the designed antenna in the proposed application.

12 September 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
CBCarolina Blanco-Angulo
Carolina Blanco-Angulo
AMAndrea Martínez-Lozano
Andrea Martínez-Lozano
Roberto GutiérrezRoberto Gutiérrez
Roberto Gutiérrez
Carlos G. JuanCarlos G. Juan
Carlos G. Juan
Héctor García-MartínezHéctor García-Martínez
Héctor García-Martínez
Ernesto ÁvilaErnesto Ávila
Ernesto Ávila
This work introduces a microwave-based system able to detect tumours in breast phantoms in a non-invasive way. The data acquisition system is composed of a hardware system which involves high-frequency components (antennas, switches and cables), a microcontroller, a vector network analyser used as measurement instrument and a computer devoted to the control and automation of the operation of the system. Concerning the software system, the computer runs a Python script which is in charge of mastering and automatising all the required stages for the data acquisition, from initialisation of the hardware system to performing and saving the measurements. We also report on the design of the high-performance broadband antenna used to carry out the measurements, as well as on the algorithm employed to build the final medical images, based on an adapted version of the so-called Improved Delay-and-Sum (IDAS) algorithm improved by a Hamming window filter and averaging preprocessing. The calibration and start-up of the system are also described. The experimental validation includes the use of different tumour models with different dielectric properties inside the breast phantom. The results show promising tumour detection capabilities, even when there is low dielectric contrast between the tumoural and healthy tissues, as is the usual case for dense breasts in young women.