Kyuseok Kim

Prof. Kyuseok Kim

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
Haneul LeeHaneul Lee
Haneul Lee
KKKyuseok Kim
Kyuseok Kim
YLYoungjin Lee
Youngjin Lee
Shear wave elastography with ultrasound is a noninvasive method used for measuring stiffness in the human body. Shear wave elastography can be used for accurately and quantitatively measuring stiffness. However, its disadvantage is that the stiffness value can vary significantly because the region of interest (ROI) setting depends on the diagnostic operator. In this study, a stiffness measurement program using color mapping in shear wave elastography was developed to address the above-mentioned disadvantage. Color map and color ratios were obtained and evaluated for major lower limb muscles (i.e., biceps femoris, medial gastrocnemius, rectus femoris, and tibialis anterior) at active voluntary contraction. According to the result, when the developed program was used, a small standard deviation compared to the conventional stiffness measurement method, such as kilopascal or meter per second unit using ROIs, was measured in all cases. In conclusion, our results demonstrate that the stiffness measurement method using our program is expected to improve reliability in shear wave elastography ultrasound imaging.

23 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
HKHajin Kim
Hajin Kim
SLSewon Lim
Sewon Lim
MPMinji Park
Minji Park
KKKyuseok Kim
Kyuseok Kim
SKSeong-Hyeon Kang
Seong-Hyeon Kang
YLYoungjin Lee
Youngjin Lee
Noise in computed tomography (CT) is inevitably generated, which lowers the accuracy of disease diagnosis. The non-local means approach, a software technique for reducing noise, is widely used in medical imaging. In this study, we propose a noise reduction algorithm based on fast non-local means (FNLMs) and apply it to CT images of a phantom created using 3D printing technology. The self-produced phantom was manufactured using filaments with similar density to human brain tissues. To quantitatively evaluate image quality, the contrast-to-noise ratio (CNR), coefficient of variation (COV), and normalized noise power spectrum (NNPS) were calculated. The results demonstrate that the optimized smoothing factors of FNLMs are 0.08, 0.16, 0.22, 0.25, and 0.32 at 0.001, 0.005, 0.01, 0.05, and 0.1 of noise intensities, respectively. In addition, we compared the optimized FNLMs with noisy, local filters and total variation algorithms. As a result, FNLMs showed superior performance compared to various denoising techniques. Particularly, comparing the optimized FNLMs to the noisy images, the CNR improved by 6.53 to 16.34 times, COV improved by 6.55 to 18.28 times, and the NNPS improved by 10−2 mm2 on average. In conclusion, our approach shows significant potential in enhancing CT image quality with anthropomorphic phantoms, thus addressing the noise issue and improving diagnostic accuracy.

26 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLSewon Lim
Sewon Lim
MPMinji Park
Minji Park
HKHajin Kim
Hajin Kim
SKSeong-Hyeon Kang
Seong-Hyeon Kang
KKKyuseok Kim
Kyuseok Kim
YLYoungjin Lee
Youngjin Lee
In low-dose computed tomography (LDCT), lung segmentation effectively improves the accuracy of lung cancer diagnosis. However, excessive noise is inevitable in LDCT, which can decrease lung segmentation accuracy. To address this problem, it is necessary to derive an optimized kernel size when using the median modified Wiener filter (MMWF) for noise reduction. Incorrect application of the kernel size can result in inadequate noise removal or blurring, degrading segmentation accuracy. Therefore, various kernel sizes of the MMWF were applied in this study, followed by region-growing-based segmentation and quantitative evaluation. In addition to evaluating the segmentation performance, we conducted a similarity assessment. Our results indicate that the greatest improvement in segmentation performance and similarity was at a kernel size 5 × 5. Compared with the noisy image, the accuracy, F1-score, intersection over union, root mean square error, and peak signal-to-noise ratio using the optimized MMWF were improved by factors of 1.38, 33.20, 64.86, 7.82, and 1.30 times, respectively. In conclusion, we have demonstrated that by applying the MMWF with an appropriate kernel size, the optimization of noise and blur reduction can enhance segmentation performance.

1 August 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YKYeonkyeon Kim
Yeonkyeon Kim
KKKyu Bom Kim
Kyu Bom Kim
ALAh Young Leem
Ah Young Leem
KKKyuseok Kim
Kyuseok Kim
SLSu Hwan Lee
Su Hwan Lee
Background/Objectives: Identifying and classifying abnormal lung sounds is essential for diagnosing patients with respiratory disorders. In particular, the simultaneous recording of auscultation signals from multiple clinically relevant positions offers greater diagnostic potential compared to traditional single-channel measurements. This study aims to improve the accuracy of respiratory sound classification by leveraging multichannel signals and capturing positional characteristics from multiple sites in the same patient. Methods: We evaluated the performance of respiratory sound classification using multichannel lung sound data with a deep learning model that combines a convolutional neural network (CNN) and long short-term memory (LSTM), based on mel-frequency cepstral coefficients (MFCCs). We analyzed the impact of the number and placement of channels on classification performance. Results: The results demonstrated that using four-channel recordings improved accuracy, sensitivity, specificity, precision, and F1-score by approximately 1.11, 1.15, 1.05, 1.08, and 1.13 times, respectively, compared to using three, two, or single-channel recordings. Conclusions: This study confirms that multichannel data capture a richer set of features corresponding to various respiratory sound characteristics, leading to significantly improved classification performance. The proposed method holds promise for enhancing sound classification accuracy not only in clinical applications but also in broader domains such as speech and audio processing.

3 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RKRyeonhui Kim
Ryeonhui Kim
KKKyuseok Kim
Kyuseok Kim
YLYoungjin Lee
Youngjin Lee
Ultrasound imaging is widely used as a noninvasive lesion detection method in diagnostic medicine. Improving the quality of these ultrasound images is very important for accurate diagnosis, and deep learning-based algorithms have gained significant attention. This study proposes a multiscale deep encoder–decoder with phase congruency (MSDEPC) algorithm based on deep learning to improve the quality of diagnostic ultrasound images. The MSDEPC algorithm included low-resolution (LR) images and edges as inputs and constructed a multiscale convolution and deconvolution network. Simulations were conducted using the Field 2 program, and data from real experimental research were obtained using five clinical datasets containing images of the carotid artery, liver hemangiomas, breast malignancy, thyroid carcinomas, and obstetric nuchal translucency. LR images, bicubic interpolation, and super-resolution convolutional neural networks (SRCNNs) were modeled as comparison groups. Through visual assessment, the image processed using the MSDEPC was the clearest, and the lesions were clearly distinguished. The structural similarity index metric (SSIM) value of the simulated ultrasound image using the MSDEPC algorithm improved by approximately 38.84% compared to LR. In addition, the peak signal-to-noise ratio (PSNR) and SSIM values of clinical ultrasound images using the MSDEPC algorithm improved by approximately 2.33 times and 88.58%, respectively, compared to LR. In conclusion, the MSDEPC algorithm is expected to significantly improve the spatial resolution of ultrasound images.

30 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
BCBo Kyung Cha
Bo Kyung Cha
YLYoungjin Lee
Youngjin Lee
KKKyuseok Kim
Kyuseok Kim
An indirect conversion X-ray detector uses a scintillator that utilizes the proportionality of the intensity of incident radiation to the amount of visible light emitted. A thicker scintillator reduces the patient’s dose while decreasing the sharpness. A thin scintillator has an advantage in terms of sharpness; however, its noise component increases. Thus, the proposed method converts the spatial resolution of radiographic images acquired from a normal-thickness scintillation detector into a thin-thickness scintillation detector. Note that noise amplification and artifacts were minimized as much as possible after non-blind deconvolution. To accomplish this, the proposed algorithm estimates the optimal point-spread function (PSF) when the structural similarity index (SSIM) and feature similarity index (FSIM) are the most similar between thick and thin scintillator images. Simulation and experimental results demonstrate the viability of the proposed method. Moreover, the deconvolution images obtained using the proposed scheme show an effective image restoration method in terms of the human visible system compared to that of the traditional PSF measurement technique. Consequently, the proposed method is useful for restoring degraded images using the adaptive PSF while preventing noise amplification and artifacts and is effective in improving the image quality in the present X-ray imaging system.