Sewon Lim

Ms. Sewon Lim


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
HKHajin Kim
Hajin Kim
SLSewon Lim
Sewon Lim
MPMinji Park
Minji Park
KKKyuseok Kim
Kyuseok Kim
SKSeong-Hyeon Kang
Seong-Hyeon Kang
YLYoungjin Lee
Youngjin Lee
Noise in computed tomography (CT) is inevitably generated, which lowers the accuracy of disease diagnosis. The non-local means approach, a software technique for reducing noise, is widely used in medical imaging. In this study, we propose a noise reduction algorithm based on fast non-local means (FNLMs) and apply it to CT images of a phantom created using 3D printing technology. The self-produced phantom was manufactured using filaments with similar density to human brain tissues. To quantitatively evaluate image quality, the contrast-to-noise ratio (CNR), coefficient of variation (COV), and normalized noise power spectrum (NNPS) were calculated. The results demonstrate that the optimized smoothing factors of FNLMs are 0.08, 0.16, 0.22, 0.25, and 0.32 at 0.001, 0.005, 0.01, 0.05, and 0.1 of noise intensities, respectively. In addition, we compared the optimized FNLMs with noisy, local filters and total variation algorithms. As a result, FNLMs showed superior performance compared to various denoising techniques. Particularly, comparing the optimized FNLMs to the noisy images, the CNR improved by 6.53 to 16.34 times, COV improved by 6.55 to 18.28 times, and the NNPS improved by 10−2 mm2 on average. In conclusion, our approach shows significant potential in enhancing CT image quality with anthropomorphic phantoms, thus addressing the noise issue and improving diagnostic accuracy.

26 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLSewon Lim
Sewon Lim
MPMinji Park
Minji Park
HKHajin Kim
Hajin Kim
SKSeong-Hyeon Kang
Seong-Hyeon Kang
KKKyuseok Kim
Kyuseok Kim
YLYoungjin Lee
Youngjin Lee
In low-dose computed tomography (LDCT), lung segmentation effectively improves the accuracy of lung cancer diagnosis. However, excessive noise is inevitable in LDCT, which can decrease lung segmentation accuracy. To address this problem, it is necessary to derive an optimized kernel size when using the median modified Wiener filter (MMWF) for noise reduction. Incorrect application of the kernel size can result in inadequate noise removal or blurring, degrading segmentation accuracy. Therefore, various kernel sizes of the MMWF were applied in this study, followed by region-growing-based segmentation and quantitative evaluation. In addition to evaluating the segmentation performance, we conducted a similarity assessment. Our results indicate that the greatest improvement in segmentation performance and similarity was at a kernel size 5 × 5. Compared with the noisy image, the accuracy, F1-score, intersection over union, root mean square error, and peak signal-to-noise ratio using the optimized MMWF were improved by factors of 1.38, 33.20, 64.86, 7.82, and 1.30 times, respectively. In conclusion, we have demonstrated that by applying the MMWF with an appropriate kernel size, the optimization of noise and blur reduction can enhance segmentation performance.

7 December 2023 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
SLSewon Lim
Sewon Lim
HNHayun Nam
Hayun Nam
HSHyemin Shin
Hyemin Shin
SJSein Jeong
Sein Jeong
KKKyuseok Kim
Kyuseok Kim
YLYoungjin Lee
Youngjin Lee
In this study, we aimed to address the issue of noise amplification after scatter correction when using a virtual grid in breast X-ray images. To achieve this, we suggested an algorithm for estimating noise level and developed a noise reduction algorithm based on generative adversarial networks (GANs). Synthetic scatter in breast X-ray images were collected using Sizgraphy equipment and scatter correction was performed using dedicated software. After scatter correction, we determined the level of noise using noise-level function plots and trained a GAN using 42 noise combinations. Subsequently, we obtained the resulting images and quantitatively evaluated their quality by measuring the contrast-to-noise ratio (CNR), coefficient of variance (COV), and normalized noise–power spectrum (NNPS). The evaluation revealed an improvement in the CNR by approximately 2.80%, an enhancement in the COV by 12.50%, and an overall improvement in the NNPS across all frequency ranges. In conclusion, the application of our GAN-based noise reduction algorithm effectively reduced noise and demonstrated the acquisition of improved-quality breast X-ray images.

22 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
SLSewon Lim
Sewon Lim
HKHajin Kim
Hajin Kim
KSKang-Hyeon Seo
Kang-Hyeon Seo
YLYoungjin Lee
Youngjin Lee
Accurate segmentation of abdominal aortic aneurysm (AAA) from computed tomography (CT) images is critical for early diagnosis and treatment planning of vascular diseases. However, noise in CT images obscures vessel boundaries, reducing segmentation accuracy. U-Net is widely used for medical image segmentation, where noise removal is critical. This study applied various denoising filters for U-Net segmentation and classified the severity of segmented AAA images to evaluate accuracy. Poisson–Gaussian noise was added to AAA CT images, and then average, median, Wiener, and median-modified Wiener filters (MMWF) were applied. U-Net-based segmentation was performed, and the segmentation accuracy of the output images obtained per filter was quantitatively assessed. Furthermore, the Hough circle algorithm was applied to the segmented images for diameter measurement, enabling severity classification and evaluation of classification accuracy. MMWF application improved the Matthews correlation coefficient, Dice score, Jaccard coefficient, and mean surface distance by 31.09%, 34.25%, 53.99%, and 3.70%, respectively, compared with images with added noise. Moreover, classification based on the output images obtained after MMWF application demonstrated the highest accuracy, with sensitivity, precision, and accuracy reaching 100%. Thus, U-Net-based segmentation yields more accurate results when images are processed with the MMWF and analyzed using the Hough circle algorithm.