Serena Barbera

Mrs. Serena Barbera


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
CDCarolina Dolci
Carolina Dolci
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
SCStefania Costa
Stefania Costa
SBSerena Barbera
Serena Barbera
Marco PortelliMarco Portelli
Marco Portelli
This systematic review aims to highlight the differences between different clear aligner therapies that differ in the presence of attachments or in attachment configuration. Eight electronic databases were searched up to March 2020. Two authors independently proceeded to study selection, data extraction, and risk of bias assessment. The analysis of the results was carried out examining six groups of movements (mesio-distal tipping/bodily movement; anterior bucco-lingual tipping/root torque; posterior bucco-lingual tipping/expansion; intrusion; extrusion; rotation). Five clinical trials were selected and all of them showed a medium risk of bias. Literature showed that attachments mostly increase the effectiveness of orthodontic treatment with clear aligners, improving anterior root torque, rotation, and mesio-distal (M-D) movement; they are also important to increase posterior anchorage. However, some articles showed contradictory or not statistically significant results. Attachments also seem to improve intrusion, but the evidence about this movement, as well as extrusion, is lacking. No studies evaluated posterior bucco-lingual tipping/expansion. Further clinical trials are strongly suggested to clarify the influence of attachments and their number, size, shape, and position on each orthodontic movement.

23 October 2023 in Materials
Verified
Journal Article
Open access
PDF file
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
Marco PortelliMarco Portelli
Marco Portelli
LCLudovica Ciraolo
Ludovica Ciraolo
ECElia Ciancio
Elia Ciancio
AMAngela Militi
Angela Militi
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Background: The purpose of this study was to evaluate some of the clinical variables that influence the accuracy of reproducing the planned attachment shape. The following clinical variables were considered: the template material, type of composite, and pressure application on the template during attachment curing. Methods: In this study, the evaluated materials for the thermoplastic transfer template construction are Erkolen 0.8 (polyethylene: PE) and Erkodur 0.8 (polyethylene terephthalate glycol—PET-G), and two types of composite resins: Enaflow (light-curing low-viscosity composite resin) and Enamel plus dentina HRI (light-curing high-viscosity composite resin). Two different light-curing lamps were used: Valo cordless color with no pressure and push light pressure (SCS). The 26 models included in the study were imported into the 3 Shape Ortho System 2022 (ver. 85.0.20 3 Shape, Denmark), and attachments were virtually placed on the dental elements of the first premolar and on both sides of the first upper molars. The accuracy of the attachment reproduction was evaluated through linear and angular evaluations against the reference model (MCAD). Three physical models were obtained: model A (MA), which was printed with attachments; model B (MB) with attachments made with a PE template; and model C (MC) with attachments made with a PET-G template. Results: The results showed statistically significant differences (p < 0.05) between the PE and PET-G templates with greater precision using the PET-G template. Statistically significant differences (p < 0.05) were found among the high-viscosity composite and low-viscosity composite with pressure curing. Conclusions: In light of the obtained data, using a PET-G template is recommended. The pressure application during composite curing reduces the reproduction accuracy with a low-viscosity composite.

30 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
ECElia Ciancio
Elia Ciancio
LCLudovica Ciraolo
Ludovica Ciraolo
SBSerena Barbera
Serena Barbera
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Background: The aim of this study was to propose a new 3D printing method for attachment production and compare the reproduction accuracy of traditional attachments with the proposed 3D-printed attachments. Methods: A standardized 3D model attachment was created with the dimensions of 3, 2, and 2 mm for the apico-coronal, mesio-distal, and vestibulo-lingual dimensions, respectively. A 3D ideal model of the maxillary arch was used to apply four standardized attachments on the vestibular surface of selected teeth. The obtained model with placed attachments was used to reproduce composite attachments via the conventional method. A transfer template was used to bond with the flow composite resin 3D-printed attachment on a new arch model without attachments. The models with traditional attachments and 3D-printed attachments were scanned and overlapped with the original CAD model with attachments. To assess the attachment precision, vertical and horizontal cutting planes were used on the overlapped models. The outcome selection focused on puff analysis (excess composite material evaluation) and shape analysis (attachment accuracy evaluation). Results: The results indicated that the 3D-printed attachments showed significant differences (p < 0.05) compared to the traditional attachments. The descriptive statistics showed the higher discrepancies compared to the CAD model of the traditionally created attachments in the shape (0.85 mm) and puff dimension (1.02 mm). Conclusion: Custom 3D-printed attachment production is an effective method for achieving greater attachment precision.

13 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
ECElia Ciancio
Elia Ciancio
SBSerena Barbera
Serena Barbera
DADomenico Aiello
Domenico Aiello
Marco PortelliMarco Portelli
Marco Portelli
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Background: The aim of this retrospective study was to conduct an in vivo evaluation of the accuracy of surgical guides obtained via 3D printing technology that were used to transfer the 3D software-planned position and axis during palatal miniscrew placement. Methods: Twenty-four Caucasian subjects with permanent dentition underwent a CBCT examination to plan palatal skeletal anchorage using two miniscrews in the anterior palatal arch. A specific software function capable of identifying and displaying all CBCT scans passing through the planned miniscrew axis was used to identify the scan showing the maximum discrepancy between the planned and final miniscrew placement. The maximum insertion angle discrepancy and the maximum linear difference between the head and tip of the miniscrew were measured on the overlaid 3D STL models of the planned miniscrew position at CBCT with the final clinical position of the miniscrew. Results: Descriptive and inferential statistics were performed. On average, there was a discrepancy between the planned insertion axis and the final insertion axis of 2.95° (SD ± 1.13°), with a 10 mm miniscrew length. Conclusion: Three-dimensional I.-printed surgical guides for palatal miniscrew placement show a mean deviation of 2.95° from the planned position, indicating good but improvable accuracy in placement.

1 May 2024 in Oral
Verified
Journal Article
Open access
PDF file
NDNicola Derton
Nicola Derton
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
ECElia Ciancio
Elia Ciancio
SBSerena Barbera
Serena Barbera
ACAndrea Caddia
Andrea Caddia
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Background: To analyze the anatomical characteristics of a posterior area in the mandible localized distally to the second molars and extending in the vestibular direction toward the bony step, which we define as “buccal step”, in a patient with different skeletal patterns for mini-screw insertion. Methods: The sample included 85 CBCT (cone beam computed tomography) records selected from the digital archive. Analysis focused on the buccal step area. Sections were obtained in axial view using reference lines, and measurements of cortical and total bone were taken at specific points M0 (starting point, 6 mm apical from CEJc—cementoenamel junction crest), M2 (located 2 mm posterior to M0 in the apical direction), and M4 (positioned 4 mm posterior to M0 in the apical direction) in both directions. Six measurements were recorded for each scan root plane, assessing cortical and total bone depth. Results: The thickness of the bone increases toward the inside of the mouth at all tested sites (M0, M2, M4), which is good for placing mini-screws. Cortical bone thickness decreases toward the inside of the mouth, with no significant differences among the sites except for M0 vs. M4. People with a particular jaw shape (hypo-divergent) have a thicker cortical bone, indicating that facial structure affects bone thickness. Conclusions: The posterior buccal step insertion site has biomechanical advantages and reduces the risk of damaging roots during mini-screw insertions.

28 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
ECElia Ciancio
Elia Ciancio
SBSerena Barbera
Serena Barbera
DADomenico Aiello
Domenico Aiello
Marco PortelliMarco Portelli
Marco Portelli
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Background: the aim of this retrospective study was to evaluate in vivo the accuracy of surgical guides obtained by 3D printing technology, used to transfer, during palatal miniscrew placement, its 3D software planned position and axis. Methods: twenty-four Caucasian subjects with permanent dentition underwent a CBCT examination to plan palatal skeletal anchorage using two miniscrews in the anterior palatal arch. A specific software function capable of identifying and displaying all CBCT scans passing through the planned miniscrew axis was used to identify the scan showing the maximum discrepancy between the planned and final miniscrew placement. The maximum insertion angle discrepancy and the maximum linear difference between the head and tip of the miniscrew were measured on the overlaid 3D STL models of the planned miniscrew position at CBCT with the final clinical position of the miniscrew. Results: descriptive and inferential Statistics were performed. On average, there was a discrepancy between the planned insertion axis and the final insertion axis of 2,95 ° (SD +/- 1.13 °), with 10 mm miniscrew length. Conclusion: 3D-printed surgical guides for palatal miniscrew placement show a mean deviation of 2.95° from the planned position, indicating good but improvable accuracy in placement.