Angela Mirea Bellocchio

Dr. Angela Mirea Bellocchio

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
CDCarolina Dolci
Carolina Dolci
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
SCStefania Costa
Stefania Costa
SBSerena Barbera
Serena Barbera
Marco PortelliMarco Portelli
Marco Portelli
This systematic review aims to highlight the differences between different clear aligner therapies that differ in the presence of attachments or in attachment configuration. Eight electronic databases were searched up to March 2020. Two authors independently proceeded to study selection, data extraction, and risk of bias assessment. The analysis of the results was carried out examining six groups of movements (mesio-distal tipping/bodily movement; anterior bucco-lingual tipping/root torque; posterior bucco-lingual tipping/expansion; intrusion; extrusion; rotation). Five clinical trials were selected and all of them showed a medium risk of bias. Literature showed that attachments mostly increase the effectiveness of orthodontic treatment with clear aligners, improving anterior root torque, rotation, and mesio-distal (M-D) movement; they are also important to increase posterior anchorage. However, some articles showed contradictory or not statistically significant results. Attachments also seem to improve intrusion, but the evidence about this movement, as well as extrusion, is lacking. No studies evaluated posterior bucco-lingual tipping/expansion. Further clinical trials are strongly suggested to clarify the influence of attachments and their number, size, shape, and position on each orthodontic movement.

21 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Francesco PuleioFrancesco Puleio
Francesco Puleio
Giorgio Lo GiudiceGiorgio Lo Giudice
Giorgio Lo Giudice
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
CBciro emiliano Boschetti
ciro emiliano Boschetti
RGRoberto Lo Giudice
Roberto Lo Giudice
Artificial intelligence (AI), specifically Generative Pre-trained Transformer (GPT) technology, has revolutionized various fields, including medicine and dentistry. The AI model ChatGPT, developed by OpenAI, mimics human language on a large scale, generating coherent and contextually appropriate responses. ChatGPT serves as an auxiliary resource for diagnosis and decision-making across various medical disciplines. This comprehensive narrative review aims to explore how ChatGPT can assist the dental sector, highlighting its potential to enhance various aspects of the discipline. This review includes a literature search on the application of ChatGPT in dentistry, with a focus on the differences between the free version, ChatGPT 3.5, and the more advanced subscription-based version, ChatGPT 4. Specifically, ChatGPT has proven to be effective in enhancing user interaction, providing fast and accurate information and improving the accessibility of knowledge. However, despite these advantages, several limitations are identified, including concerns regarding the accuracy of responses in complex scenarios, ethical considerations surrounding its use, and the need for improved training to handle highly specialized queries. In conclusion, while ChatGPT offers numerous benefits in terms of efficiency and scalability, further research and development are needed to address these limitations, particularly in areas requiring greater precision, ethical oversight, and specialized expertise.

26 July 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Marco PortelliMarco Portelli
Marco Portelli
Ignazio RussoIgnazio Russo
Ignazio Russo
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
AMAngela Militi
Angela Militi
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
The focus of this article was to evaluate the link between obstructive sleep apnea syndrome (OSAS) and periodontitis, considering various hypotheses supporting the relationship between respiratory disorders and periodontitis. The literature review for this study was performed using the PubMed, Google Scholar, Cochrane library, and Proquest databases. The review process was guided by the PRISMA guidelines. The PECOS protocol (Population, Exposure, Control, Outcome, Study) was followed in developing the search strategy to ensure consistent and accurate selection of articles. To evaluate quality, cross-sectional studies were reviewed using the Joanna Briggs Institute (JBI) critical appraisal tool. Case-control studies were assessed with the Newcastle–Ottawa Scale (NOS). The research included a total of 10 studies, encompassing 88,040 participants. The meta-analysis observed a statistically significant association between OSAS and periodontitis, with an odds ratio OR = 2.4620 (95%-CI: 1.7345–3.4946 p ≤ 0.0001). The results suggest a potential association between OSA and periodontitis. Further investigations are warranted to confirm this association and elucidate its underlying mechanism.

23 October 2023 in Materials
Verified
Journal Article
Open access
PDF file
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
Marco PortelliMarco Portelli
Marco Portelli
LCLudovica Ciraolo
Ludovica Ciraolo
ECElia Ciancio
Elia Ciancio
AMAngela Militi
Angela Militi
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Background: The purpose of this study was to evaluate some of the clinical variables that influence the accuracy of reproducing the planned attachment shape. The following clinical variables were considered: the template material, type of composite, and pressure application on the template during attachment curing. Methods: In this study, the evaluated materials for the thermoplastic transfer template construction are Erkolen 0.8 (polyethylene: PE) and Erkodur 0.8 (polyethylene terephthalate glycol—PET-G), and two types of composite resins: Enaflow (light-curing low-viscosity composite resin) and Enamel plus dentina HRI (light-curing high-viscosity composite resin). Two different light-curing lamps were used: Valo cordless color with no pressure and push light pressure (SCS). The 26 models included in the study were imported into the 3 Shape Ortho System 2022 (ver. 85.0.20 3 Shape, Denmark), and attachments were virtually placed on the dental elements of the first premolar and on both sides of the first upper molars. The accuracy of the attachment reproduction was evaluated through linear and angular evaluations against the reference model (MCAD). Three physical models were obtained: model A (MA), which was printed with attachments; model B (MB) with attachments made with a PE template; and model C (MC) with attachments made with a PET-G template. Results: The results showed statistically significant differences (p < 0.05) between the PE and PET-G templates with greater precision using the PET-G template. Statistically significant differences (p < 0.05) were found among the high-viscosity composite and low-viscosity composite with pressure curing. Conclusions: In light of the obtained data, using a PET-G template is recommended. The pressure application during composite curing reduces the reproduction accuracy with a low-viscosity composite.

30 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
ECElia Ciancio
Elia Ciancio
LCLudovica Ciraolo
Ludovica Ciraolo
SBSerena Barbera
Serena Barbera
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Background: The aim of this study was to propose a new 3D printing method for attachment production and compare the reproduction accuracy of traditional attachments with the proposed 3D-printed attachments. Methods: A standardized 3D model attachment was created with the dimensions of 3, 2, and 2 mm for the apico-coronal, mesio-distal, and vestibulo-lingual dimensions, respectively. A 3D ideal model of the maxillary arch was used to apply four standardized attachments on the vestibular surface of selected teeth. The obtained model with placed attachments was used to reproduce composite attachments via the conventional method. A transfer template was used to bond with the flow composite resin 3D-printed attachment on a new arch model without attachments. The models with traditional attachments and 3D-printed attachments were scanned and overlapped with the original CAD model with attachments. To assess the attachment precision, vertical and horizontal cutting planes were used on the overlapped models. The outcome selection focused on puff analysis (excess composite material evaluation) and shape analysis (attachment accuracy evaluation). Results: The results indicated that the 3D-printed attachments showed significant differences (p < 0.05) compared to the traditional attachments. The descriptive statistics showed the higher discrepancies compared to the CAD model of the traditionally created attachments in the shape (0.85 mm) and puff dimension (1.02 mm). Conclusion: Custom 3D-printed attachment production is an effective method for achieving greater attachment precision.

13 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
ECElia Ciancio
Elia Ciancio
SBSerena Barbera
Serena Barbera
DADomenico Aiello
Domenico Aiello
Marco PortelliMarco Portelli
Marco Portelli
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Background: The aim of this retrospective study was to conduct an in vivo evaluation of the accuracy of surgical guides obtained via 3D printing technology that were used to transfer the 3D software-planned position and axis during palatal miniscrew placement. Methods: Twenty-four Caucasian subjects with permanent dentition underwent a CBCT examination to plan palatal skeletal anchorage using two miniscrews in the anterior palatal arch. A specific software function capable of identifying and displaying all CBCT scans passing through the planned miniscrew axis was used to identify the scan showing the maximum discrepancy between the planned and final miniscrew placement. The maximum insertion angle discrepancy and the maximum linear difference between the head and tip of the miniscrew were measured on the overlaid 3D STL models of the planned miniscrew position at CBCT with the final clinical position of the miniscrew. Results: Descriptive and inferential statistics were performed. On average, there was a discrepancy between the planned insertion axis and the final insertion axis of 2.95° (SD ± 1.13°), with a 10 mm miniscrew length. Conclusion: Three-dimensional I.-printed surgical guides for palatal miniscrew placement show a mean deviation of 2.95° from the planned position, indicating good but improvable accuracy in placement.