The Italian building stock consists of buildings mainly constructed until the mid-20th century using pre-industrial construction techniques. These buildings require energy refurbishment that takes into account the preservation of their architectural heritage. In this view, this work studies an innovative integrated modelling and simulation framework consisting of the implementation of Historical Building Information Modeling (HBIM) for the energy retrofit of historical buildings with renewable geothermal HVAC system. To this aim, the field case study is part of a medieval complex in Central Italy (Perugia), as representative ancient rural offshore architecture in the European countryside. The system involves of a ground source heat pump, a water tank for thermal-energy storage connected to a low-temperature radiant system, and an air-handling unit. The building heating energy performance, typically influenced by thermal inertia in historical buildings, when coupled to the novel HVAC system, is comparatively assessed against a traditional scenario implementing a natural-gas boiler, and made inter-operative within the HBIM ad hoc platform. Results show that the innovative renewable energy system provides relevant benefits while preserving minor visual and architectural impact within the historical complex, and also in terms of both energy saving, CO2 emissions offset, and operation costs compared to the traditional existing system. The integrated HBIM approach may effectively drive the path toward regeneration and re-functioning of heritage in Europe.
The focus of the experimental work was on shallow spiral geothermal heat exchanger configurations. Real-scale experiments were carried out for vertically oriented spiral collectors (helix) in sand and soil. One objective was to develop a measurement concept in laboratory environment to create a framework for a validated database. This database serves as the basis for further and new development of engineering design tools. To achieve the highest possible data-point density in the observed environment, temperature sensors and a fiber-optic temperature measurement system (DTS) were used. Soil probes were taken in situ before and after the measurements and analyzed at a thermophysical laboratory to determine material properties. The heat flow was controlled by an electric heating cable, which was installed in the form of a spiral-shaped heat exchanger in a 1 m³ container. To guarantee constant boundary conditions, the measurements were carried out in a climate chamber at a defined ambient temperature. The evaluation of the transient response behavior is spatially resolved. The results are coordinate-based temperature points, which describe temperature gradients in all axes of the container over time, which are combined with known soil properties. The collected data was used to develop computational fluid dynamic (CFD) models, which are used to extend the variety of geometry and soil configurations for developing new design tools.
In this paper, we show that an analytical solution based on the Finite Line Source and G-function approach is both sufficiently fast and accurate for design calculations of ground heat exchangers with a complex (spiral) geometry. Detailed validations were performed for the steady-state and transient responses of analytical models with different time scales (10 h and 250 h). A comparison with a detailed computational fluid dynamics model (Ansys Fluent) and the analytical method for different boundary conditions showed a very good agreement (maximum root mean square error) smaller than 0.25 K.