In the last decade, the development of more compact and lightweight radiation detection systems led to their application in handheld and small unmanned systems, particularly air-based platforms. Examples of improvements are: the use of silicon photomultiplier-based scintillators, new scintillating crystals, compact dual-mode detectors (gamma/neutron), data fusion, mobile sensor networks, cooperative detection and search. Gamma cameras and dual-particle cameras are increasingly being used for source location. This study reviews and discusses the research advancements in the field of gamma-ray and neutron measurements using mobile radiation detection systems since the Fukushima nuclear accident. Four scenarios are considered: radiological and nuclear accidents and emergencies; illicit traffic of special nuclear materials and radioactive materials; nuclear, accelerator, targets, and irradiation facilities; and naturally occurring radioactive materials monitoring-related activities. The work presented in this paper aims to: compile and review information on the radiation detection systems, contextual sensors and platforms used for each scenario; assess their advantages and limitations, looking prospectively to new research and challenges in the field; and support the decision making of national radioprotection agencies and response teams in respect to adequate detection system for each scenario. For that, an extensive literature review was conducted.
Human populations and natural ecosystems are bound to be exposed to ionizing radiation from the deposition of artificial radionuclides resulting from nuclear accidents, nuclear devices or radiological dispersive devices (“dirty bombs”). On the other hand, Naturally Occurring Radioactive Material industries such as phosphate production or uranium mining, contribute to the on site storage of residuals with enhanced concentrations of natural radionuclides. Therefore, in the context of the European agreements concerning nuclear energy, namely the European Atomic Energy Community Treaty, monitoring is an essential feature of the environmental radiological surveillance. In this work, we obtain 3D maps from outdoor scenarios, and complete such maps with measured radiation levels and with its radionuclide signature. In such scenarios, we face challenges such as unknown and rough terrain, limited number of sampled locations and the need for different sensors and therefore different tasks. We propose a radiological solution for scouting, monitoring and inspecting an area of interest, using a fleet of drones and a controlling ground station. First, we scout an area with a Light Detection and Ranging sensor onboard a drone to accurately 3D-map the area. Then, we monitor that area with a Geiger–Müller Counter at a low-vertical distance from the ground to produce a radiological (heat)map that is overlaid on the 3D map of the scenario. Next, we identify the hotspots of radiation, and inspect them in detail using a drone by landing on them, to reveal its radionuclide signature using a Cadmium–Zinc–Telluride detector. We present the algorithms used to implement such tasks both at the ground station and on the drones. The three mission phases were validated using actual experiments in three different outdoor scenarios. We conclude that drones can not only perform the mission efficiently, but in general they are faster and as reliable as personnel on the ground.
Radiological monitoring is fundamental for compliance with radiological protection policies in the aftermath of radiological events, such as nuclear accidents, terrorism, and out-of-commission uranium mines. An effective strategy for radiation monitoring is to use radiation detectors coupled with Unmanned Aerial Vehicles (UAVs), enabling for quicker surveillance of large areas without involving the need of human presence in the target area. The main aim of this study was to formulate the parameters for a UAV flight strategy in preparation for future field measurements using Geiger–Muller Counters (GMC) and Cadmium Zinc Telluride (CZT) spectrometers. As a proof of concept, the prepared flight strategy will be used to survey out-of-commission uranium mines in northern Portugal. Procedures to assure the calibration of the CZT and verification of the GMCs were conducted, as well as a sensitivity analysis of the sensors considering different acquisition times, distance to source, and detector response time. This article reports specific parameters, such as UAV distance to ground, time of exposition, speed, and the methodology to perform the identification and calculate the activity of possible radioactive sources. An effective flight strategy is also presented, aiming to use radiation detectors coupled with UAVs to undertake extensive monitoring of areas with enhanced levels of environmental radiation, which is of prime importance due to the lasting hazardous effects of enhanced environmental radiation in the nearby ecosystem and population.