Jorge Borbinha

Mr. Jorge Borbinha

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LPLuis Pinto
Luis Pinto
Alberto ValeAlberto Vale
Alberto Vale
YBYoeri Brouwer
Yoeri Brouwer
JBJorge Borbinha
Jorge Borbinha
José CoriscoJosé Corisco
José Corisco
Bruno GoncalvesBruno Goncalves
Bruno Goncalves
Human populations and natural ecosystems are bound to be exposed to ionizing radiation from the deposition of artificial radionuclides resulting from nuclear accidents, nuclear devices or radiological dispersive devices (“dirty bombs”). On the other hand, Naturally Occurring Radioactive Material industries such as phosphate production or uranium mining, contribute to the on site storage of residuals with enhanced concentrations of natural radionuclides. Therefore, in the context of the European agreements concerning nuclear energy, namely the European Atomic Energy Community Treaty, monitoring is an essential feature of the environmental radiological surveillance. In this work, we obtain 3D maps from outdoor scenarios, and complete such maps with measured radiation levels and with its radionuclide signature. In such scenarios, we face challenges such as unknown and rough terrain, limited number of sampled locations and the need for different sensors and therefore different tasks. We propose a radiological solution for scouting, monitoring and inspecting an area of interest, using a fleet of drones and a controlling ground station. First, we scout an area with a Light Detection and Ranging sensor onboard a drone to accurately 3D-map the area. Then, we monitor that area with a Geiger–Müller Counter at a low-vertical distance from the ground to produce a radiological (heat)map that is overlaid on the 3D map of the scenario. Next, we identify the hotspots of radiation, and inspect them in detail using a drone by landing on them, to reveal its radionuclide signature using a Cadmium–Zinc–Telluride detector. We present the algorithms used to implement such tasks both at the ground station and on the drones. The three mission phases were validated using actual experiments in three different outdoor scenarios. We conclude that drones can not only perform the mission efficiently, but in general they are faster and as reliable as personnel on the ground.

10 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JBJorge Borbinha
Jorge Borbinha
YRYuriy Romanets
Yuriy Romanets
PTPedro Teles
Pedro Teles
José CoriscoJosé Corisco
José Corisco
PVPedro Vaz
Pedro Vaz
Bruno GoncalvesBruno Goncalves
Bruno Goncalves
Radiological monitoring is fundamental for compliance with radiological protection policies in the aftermath of radiological events, such as nuclear accidents, terrorism, and out-of-commission uranium mines. An effective strategy for radiation monitoring is to use radiation detectors coupled with Unmanned Aerial Vehicles (UAVs), enabling for quicker surveillance of large areas without involving the need of human presence in the target area. The main aim of this study was to formulate the parameters for a UAV flight strategy in preparation for future field measurements using Geiger–Muller Counters (GMC) and Cadmium Zinc Telluride (CZT) spectrometers. As a proof of concept, the prepared flight strategy will be used to survey out-of-commission uranium mines in northern Portugal. Procedures to assure the calibration of the CZT and verification of the GMCs were conducted, as well as a sensitivity analysis of the sensors considering different acquisition times, distance to source, and detector response time. This article reports specific parameters, such as UAV distance to ground, time of exposition, speed, and the methodology to perform the identification and calculate the activity of possible radioactive sources. An effective flight strategy is also presented, aiming to use radiation detectors coupled with UAVs to undertake extensive monitoring of areas with enhanced levels of environmental radiation, which is of prime importance due to the lasting hazardous effects of enhanced environmental radiation in the nearby ecosystem and population.

26 March 2020 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JTJoonas Samuli Tikkanen
Joonas Samuli Tikkanen
KZKlemens Zink
Klemens Zink
MPMaria Pimpinella
Maria Pimpinella
PTPedro Teles
Pedro Teles
JBJorge Borbinha
Jorge Borbinha
MPMassimo Pinto
Massimo Pinto
The beam quality correction factor, , which corrects for the difference in the ionization chamber response between the reference and clinical beam quality, is an integral part of radiation therapy dosimetry. The uncertainty of is one of the most significant sources of uncertainty in the dose determination. To improve the accuracy of available data, four partners calculated factors for 10 ionization chamber models in linear accelerator beams with accelerator voltages ranging from 6 MV to 25 MV, including flattening-filter-free (FFF) beams. The software used in the calculations were EGSnrc and PENELOPE, and the ICRU report 90 cross section data for water and graphite were included in the simulations. Volume averaging correction factors were calculated to correct for the dose averaging in the chamber cavities. A comparison calculation between partners showed a good agreement, as did comparison with literature. The values from TRS-398 were higher than our values for each chamber where data was available. The values for the FFF beams did not follow the same , relation as beams with flattening filter (values for 10 MV FFF beams were below fits made to other data on average by 0.3%), although our FFF sources were only for Varian linacs.

1 January 2022 in Radiation Measurements
Verified
Journal Article
Open access
CHChristelle Huet
Christelle Huet
JEJonathan Eakins
Jonathan Eakins
MZMaria Zankl
Maria Zankl
JGJosé María Gómez-Ros
José María Gómez-Ros
JJJan Jansen
Jan Jansen
KTKatarzyna Tymińska
Katarzyna Tymińska


1 November 2021 in Radiation Measurements
Verified
Journal Article
Open access
MZMaria Zankl
Maria Zankl
JRJosé-María Gómez Ros
José-María Gómez Ros
MMMontserrat Moraleda
Montserrat Moraleda
URUwe Reichelt
Uwe Reichelt
DADeepak K. Akar
Deepak K. Akar
STSebastian Triviño
Sebastian Triviño