The SARS-CoV-2 virus emerged in December 2019 and then spread globally. Little is still known about the impact of COVID-19 on pregnant women and neonates. A review of the literature was performed according to the PRISMA guideline recommendations, searching the MEDLINE and EMBASE databases. Studies’ quality assessments were performed using the JBI Critical Appraisal Checklist. A total of 37 studies were included, involving 275 pregnant women with COVID-19 and 248 neonates. The majority of pregnant women presented with mild to moderate symptoms, only 10 were admitted in the ICU, and one died. Two stillbirths were reported and the incidence of prematurity was 28%. Sixteen neonates were tested positive for SARS-CoV-2 by RT-PCR, and nine of them were born from mothers infected during pregnancy. Neonatal outcomes were generally good: all the affected neonates recovered. RT-PCR for SARS-CoV-2 yielded negative results on amniotic fluid, vaginal/cervical fluids, placenta tissue, and breast milk samples. SARS-CoV-2 infection in pregnant women appeared associated with mild or moderate disease in most cases, with a low morbidity and mortality rate. The outcomes of neonates born from infected women were mainly favorable, although neonates at risk should be closely monitored. Further studies are needed to investigate the possibility of vertical transmission.
Background Meconium-stained amniotic fluid (MSAF) is considered an alarming sign of possible fetal compromise and it has recently been reported that neonatal outcome correlates with the degree of meconium thickness. Methods We retrospectively studied 400 term infants allocated in clear amniotic fluid and grade 1, 2, and 3 MSAF groups on the basis of color and thickness of AF. Multivariable logistic regression analysis was performed to evaluate the potential independent effect of delivery with MSAF of different severity on the risk of a composite adverse neonatal outcome. Results We found that delivery with grade 2 (OR 16.82, 95% Cl 2.12–33.52; p = 0.008) and 3 (OR 33.79, 95% Cl 4.24–69.33; p < 0.001) MSAF is independently correlated with the risk of adverse neonatal outcome, such as the occurrence of at least one of the following: need of resuscitation in the delivery room, blood cord pH < 7.100, occurrence of meconium aspiration syndrome (MAS), persistent pulmonary hypertension (PPH), transient tachypnea of the newborn (TTN), acute respiratory distress syndrome (ARDS), hypoxic-ischemic encephalopathy (HIE), and sepsis. Conclusions There is a positive correlation between the severity of amniotic fluid meconium staining and thickness and the outcomes of term infants. Therefore, the evaluation and grading of MSAF during labor is useful in order to plan for the presence of a neonatologist at delivery for immediate and proper neonatal care.
We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included. Accuracy was assessed by comparison with LVO. Intra- and inter-observer reproducibility of the off-line analysis were assessed. Forty-five neonates were included. RVO calculation with tip-PVD was more accurate than hinge-PVD in comparison with LVO, r2 0.712 versus 0.464, bias (95% limits of agreement) 1.4 mL/kg/min (−26–29 mL/kg/min) versus 61 mL/kg/min (−11–132 mL/kg/min), respectively. Both hinge-PVD and tip-PVD presented similar reproducibility, with an intra-observer bias (95% LOA) of 0.3 (−1.0–0.5) and –0.2 (−0.8–0.5) respectively, and an inter-observer bias of 0.1 (−1.3–1.6) and 0.1 (−1.4–1.6). RVO calculation using tip-PVD was more accurate than the conventional technique, with similar reproducibility.
Background: Low platelet count might promote resistance to pharmacological closure with indomethacin and ibuprofen of a hemodynamically significant patent ductus arteriosus (hsPDA). However, no studies have investigated if this occurs with paracetamol. Methods: We retrospectively assessed the correlation between platelet count, mean platelet volume (MPV), and plateletcrit (PCT), as well as the effectiveness of paracetamol in closing hsPDA in infants born at 23+0–31+6 weeks of gestation who were treated with 15 mg/kg/6 h of i.v. paracetamol for 3 days. Results: We studied 79 infants: 37 (47%) Had closure after a course of paracetamol and 42 (53%) did not. Platelet count and PCT did not correlate with paracetamol success or failure in closing hsPDA, while MPV was lower at birth (10.7 ± 1.4 vs. 9.5 ± 1.1; p < 0.001) and prior to starting therapy (11.7 ± 1.9 vs. 11.0 ± 1.6; p = 0.079) in refractory infants. Regression analysis confirmed that the low MVP measured prior to starting the treatment increased the risk of hsPDA paracetamol closure failure (OR 1.664, 95% CI 1.153–2.401). Conclusions: The greater MPV correlated positively with the effectiveness of paracetamol in closing hsPDA, while platelet count and PCT did not influence closure rates. Additional studies are needed to confirm our results.