Silvia Nogara

Dr. Silvia Nogara

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
BFBenjamim Ficial
Benjamim Ficial
ICIuri Corsini
Iuri Corsini
EBElena Bonafiglia
Elena Bonafiglia
EPEnrico Petoello
Enrico Petoello
AFAlice Iride Flore
Alice Iride Flore
AGAlan M. Groves
Alan M. Groves
Ultrasound Superior Vena Cava (SVC) flow assessment is a common measure of systemic and cerebral perfusion, although accuracy is limited. The aim of this study was to evaluate whether any improvements in accuracy could be achieved by measuring stroke distance from the instantaneous mean velocity, rather than from peak velocity, and by directly tracing area from images obtained with a high frequency linear probe. Paired phase contrast magnetic resonance imaging (PCMRI) and ultrasound assessments of SVC flow were performed in a pilot cohort of 7 infants. Median postnatal age, corrected gestation and weight at scan were 7 (2–74) days, 34.8 (31.7–37.2) weeks 1870 (970–2660) g. Median interval between PCMRI and ultrasound scans was 0.3 (0.2–0.5) h. The methodology trialed here showed a better agreement with PCMRI (mean bias −8 mL/kg/min, LOA −25–+8 mL/kg/min), compared to both the original method reported by Kluckow et al. (mean bias + 42 mL/kg/min, LOA −53–+137 mL/kg/min), and our own prior adaptation (mean bias + 23 mL/kg/min, LOA −25–+71 mL/kg/min). Ultrasound assessment of SVC flow volume using the modifications described led to enhanced accuracy and decreased variability compared to prior techniques in a small cohort of premature infants.

Verified
Journal Article
Open access
PDF file
CMCarlotta Milocchi
Carlotta Milocchi
SNSilvia Nogara
Silvia Nogara
GMGiorgia Mazzuca
Giorgia Mazzuca
FRFederica Runfola
Federica Runfola
MCMartina Ciarcià
Martina Ciarcià
BFBenjamim Ficial
Benjamim Ficial
We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included. Accuracy was assessed by comparison with LVO. Intra- and inter-observer reproducibility of the off-line analysis were assessed. Forty-five neonates were included. RVO calculation with tip-PVD was more accurate than hinge-PVD in comparison with LVO, r2 0.712 versus 0.464, bias (95% limits of agreement) 1.4 mL/kg/min (−26–29 mL/kg/min) versus 61 mL/kg/min (−11–132 mL/kg/min), respectively. Both hinge-PVD and tip-PVD presented similar reproducibility, with an intra-observer bias (95% LOA) of 0.3 (−1.0–0.5) and –0.2 (−0.8–0.5) respectively, and an inter-observer bias of 0.1 (−1.3–1.6) and 0.1 (−1.4–1.6). RVO calculation using tip-PVD was more accurate than the conventional technique, with similar reproducibility.