Recently, digital technology has been used in dentistry to enhance accuracy and to reduce operative time. Due to advances in digital technology, the integration of individual mandibular motion into the mapping of the occlusal surface is being attempted. The Patient Specific Motion (PSM) is one such method. However, it is not clear whether the occlusal design that is adjusted using PSM could clinically show reduced occlusal error compared to conventional methods based on static occlusion. In this clinical comparative study including fifteen patients with a single posterior zirconia crown treatment, the occlusal surface after a clinical adjustment was compared to no adjustment (NA; design based on static occlusion), PSM (adjusted using PSM), and adjustment using a semi-adjustable articulator (SA) for the assessment of occlusal error. The root mean square (RMS; μm), average deviation value (±AVG; μm), and proportion inside the tolerance (in Tol; %) were calculated using the entire, subdivided occlusal surface and the out of tolerance area. Using a one-way ANOVA, the RMS and +AVG from the out of tolerance area showed a statistical difference between PSM (202.3 ± 39.8 for RMS, 173.1 ± 31.3 for +AVG) and NA (257.0 ± 73.9 for RMS, 210.9 ± 48.6 for +AVG). For the entire and subdivided occlusal surfaces, there were no significant differences. In the color-coded map analysis, PSM demonstrated a reduced occlusal error compared to NA. In conclusion, adjustment occlusal design using PSM is a simple and effective method for reducing occlusal errors that are difficult to identify in a current computer-aided design (CAD) workflow with static occlusion.
Fabricating a complete denture in a conventional manner may be complicated and difficult. The purpose of this article was to describe the benefits of a fully digital workflow and fabrication procedure of complete dentures based on digital impressions of edentulous jaws. The digital data for the workflow were acquired using an intraoral scanner and were then used to design the denture base and teeth. The resulting data were exported to a 3D printer or a milling machine for denture fabrication.
12 August 2019 in Clinical Implant Dentistry and Related Research
Dentists have made prostheses using traditional methods, which are inconvenient and time-consuming. It includes functional impression taking, plaster model production, wax rim production, intermaxillary relationship and occlusal plane setting, artificial tooth arrangement, denture polymerization, polishing, etc. To make prostheses in this way, the patient has to visit the dentist several times, and it takes a long time for them to receive treatment. In addition, the potential for errors associated with the denture-manufacturing process and the use of denture materials has always existed. However, the recent use of digital technology in dentistry has made it possible to create digital prostheses. Several techniques for the immediate loading of implants with a fixed prostheses in edentulous patients have been developed. However, these techniques are partially digital techniques that include laboratory work for prosthesis fabrication. This article aimed to describe a fully digital technique for implant-supported fixed prostheses. It includes intra-oral scanning of edentulous patients, implant placement planning, and final prosthesis fabrication. This technique facilitates a simple and more efficient immediate restoration after implant placement without using stone casts.
Background Submental intubation has been the recommended airway management procedure for maxillofacial surgery since proposed by Altemir in 1986. We adopted various submental intubation modifications based on modified intubation protocols and report on the effectiveness and problems of each modified method.Case Among a total of 13 submental intubation cases during the last five years, five representative methods are described. The proximal end of the endotracheal tube was protected by a nelaton catheter in case 1, by a suction connector in case 2, and by a dental needle cap in case 3. In case 4, a nasal speculum was used to expand a single route, and in case 5, a laparoscopic trocar was used to secure a single route.Conclusions Use of a laparoscopic trocar might be the most effective way to obtain a single submental route. However, considering cost, use of a nasal speculum is also an effective suboptimal solution.